Schneider Electric RGZE1S35M RGZ socket for RXG1

Description

RGZE1S35M: RGZ socket for RXG1 plug-in relays with screw terminals

The RGZE1S35M is a Schneider Electric Harmony socket from the RGZ series, supplied without a relay. The datasheet names it a socket with separate contact terminals, for plug-in relays of type RXG1 with 1 changeover contact, rated 10 A and 250 V AC, with screw connectors. It can be fixed by two screws on a panel or clipped onto a 35 mm symmetrical DIN rail. Seven Star LLC supplies the RGZE1S35M in Oman and the GCC as an independent supplier based in Muscat.

Reading the reference: the RGZ prefix marks the socket series, and the relay type is stated in the datasheet title (RXG1), so the compatible relay is identified by its type and by its number of contacts, 1 changeover. Treat the two sockets in this family, RGZE1S35M and RGZE1S48M, as different parts: they are not interchangeable between RXG2 and RXG1 relays.

Technical specifications of the RGZE1S35M

Parameter Specification
Manufacturer / part number Schneider Electric / RGZE1S35M
Product compatibility Plug-in relay RXG with 1 C/O contact
Contacts 1 C/O
[Ui] rated insulation voltage 250 V
[Uimp] rated impulse withstand 6 kV between coil and contact with reinforced insulation; 4 kV between terminals and DIN rail with basic insulation
[Ue] rated operational voltage 250 V conforming to IEC; 300 V conforming to UL
Dielectric strength 5 kV between coil and contact with reinforced insulation; 3 kV between terminals and DIN rail with basic insulation
Connections – terminals Screw terminals, 1 × 0.34–1 × 2.5 mm² (22 AWG–14 AWG) flexible with cable end; Screw terminals, 2 × 0.34–2 × 1 mm² (22 AWG–17 AWG) flexible with cable end; Screw terminals, 2 × 0.5–2 × 1.5 mm² (20 AWG–16 AWG) solid without cable end; Screw terminals, 1 × 0.5–1 × 2.5 mm² (20 AWG–14 AWG) solid without cable end
Fixing mode Screw (panel); Clip-on (35 mm symmetrical DIN rail)
Wire stripping length 6–7 mm
Contact terminal arrangement Separate
Screw type M3
Overvoltage category III
Pollution degree 3
Standards UL 508, CSA C22.2 No 14, IEC 61984
Product certifications CE, EAC, UL, CSA, DNV-GL
IP degree of protection IP20
Relative humidity 10–85 %
Storage temperature -40 to 85 °C
Operating temperature -40 to 70 °C
Packing 1 piece, 36 g; 10 pieces in the second package level
Country of origin China
Warranty 18 months

The RGZE1S35M compared with its sibling socket

The table compares the two RGZ sockets we hold datasheets for.

Part number Function Range Contacts Width / fixing
RGZE1S35M (this page) Socket for RXG with 1 changeover contact 250 V IEC / 300 V UL 1 changeover Panel or DIN rail
RGZE1S48M Socket for RXG with 2 changeover contact 250 V IEC / 300 V UL 2 changeover Panel or DIN rail

Pairing the RGZE1S35M with a plug-in relay

The socket is intended for Plug-in relay RXG with 1 C/O contact. A relay of that type brings the coil voltage and contact data, while the socket provides terminals, mounting and insulation. Before ordering, write down the coil voltage and the load that the relay will switch, and then check them against the relay datasheet and against the figures of the socket given above.

If the load needs more contacts than 1 changeover contact, a different relay and socket pair is needed. Do not plug relays with a different contact count or footprint into this base. Spare relays are normally kept for critical circuits, and stocking the correct socket allows a technician to change the relay without a rewire.

Where the RGZE1S35M is used in Oman and the GCC

Typical places include control cabinets and skid panels built on DIN rail, where relays must be swapped quickly without rewiring. The same base is also found in interface and signal-isolation duties in plants, buildings and utilities, and with machine builders who want a standard footprint across projects. Dust and coastal humidity are regular concerns, so closed enclosures and clean contacts matter more than the socket choice itself.

Environment and approvals for the RGZE1S35M

Storage is listed at -40 to 85 °C and operation at -40 to 70 °C. Protection is IP20 and relative humidity is 10–85 %. Standards listed: UL 508, CSA C22.2 No 14, IEC 61984. Certifications listed: CE, EAC, UL, CSA, DNV-GL.

In the Gulf a relay base sitting in a closed enclosure sees heat from its own coil and from neighbouring equipment. Leave the relay free to dissipate heat, and check the full assembly, base plus relay, against the temperature of the enclosure and the load current.

Insulation, voltage and pollution data for the RGZE1S35M

The rated insulation voltage is 250 V. The operational voltage is listed as 250 V conforming to IEC; 300 V conforming to UL. Impulse withstand is listed as 6 kV between coil and contact with reinforced insulation; 4 kV between terminals and DIN rail with basic insulation, and dielectric strength as 5 kV between coil and contact with reinforced insulation; 3 kV between terminals and DIN rail with basic insulation.

The overvoltage category is III and the pollution degree is 3. These numbers matter when a panel is checked against project requirements for clearance and creepage, and they apply to the socket itself. The relay that you plug in has its own data, and the lower of the two limits governs the assembly.

What a relay socket does and why the RGZE1S35M is built this way

A socket lets a plug-in relay be replaced in seconds without touching the field wiring. The cables stay clamped in the screw terminals of the base, and the relay is simply pulled from its position and a new one is plugged in. For plants where a failed relay must be changed during a short outage, this is a major saving compared with wiring the relay directly.

On the RGZE1S35M, the contact terminal arrangement is listed as Separate. Separate contact terminals keep the coil circuit and the load circuit on opposite sides of the base, which helps with clear wiring and with the insulation distances that the datasheet quotes between coil and contact.

Information to send with an RFQ for the RGZE1S35M

  • Exact reference RGZE1S35M and quantity.
  • Relay type and coil voltage of the relays to be fitted.
  • Load voltage and current to be switched.
  • Fixing method, panel or DIN rail.
  • Whether relays and accessories are needed in the same order.
  • Delivery location and timeline.

Documents and quotation

The Schneider Electric datasheet for the this unit is attached on this page and holds the full specification summarised above, as printed on the manufacturer’s document dated 8 Nov 2026.

Send us the reference this unit, quantity and delivery location and Seven Star LLC will reply to your request. We supply as an independent supplier based in Muscat and do not act for the manufacturer.

Datasheets & Documents
  • PDF Datasheet Schneider Electric RGZE1S35M Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric RGZE1S35M RGZ socket for RXG1

Answers from our engineering team on installation, compatibility and integration.

01What is the RGZE1S35M used for?
It is a Harmony RGZ socket for Plug-in relay RXG with 1 C/O contact, with screw connectors and separate contact terminals. It carries the relay and the field wiring so that the relay can be exchanged without rewiring.
02What are the electrical ratings of the RGZE1S35M?
The datasheet lists a rated insulation voltage of 250 V and an operational voltage of 250 V per IEC and 300 V per UL, with overvoltage category III and pollution degree 3.
03How is the RGZE1S35M fixed and wired?
It can be screwed to a panel or clipped onto a 35 mm DIN rail. Terminals are M3 screw type and the wire stripping length is 6…7 mm.
04What temperatures does the RGZE1S35M allow?
Operation is listed at -40 to 70 °C and storage at -40 to 85 degrees C, with IP20 protection and relative humidity of 10…85 %.
05Is the RGZE1S35M supplied with a relay?
The datasheet describes the socket only. The matching plug-in relay is a separate item, so state the relay type and coil voltage in your request.