Brand: Schneider Electric
Schneider Electric RE48AML12MW Harmony Timer Relay
Description
RE48AML12MW: panel-mounted/plug-in timer relay with 0.02 s to 300 h timing
The RE48AML12MW is a Schneider Electric Harmony timer relay in the panel-mounted/plug-in timer relay format, component name RE48A. It offers 4 timing functions, a relay output with 2 changeover contacts, a rated supply of 24–240 V AC/DC, and a body 48 mm wide. Time can be set from 0.02 s to 300 h through 14 selectable ranges. Seven Star LLC supplies the RE48AML12MW in Oman and the GCC as an independent supplier based in Muscat.
Supply and output of the RE48AML12MW
RE48AML12MW is rated for 24–240 V AC/DC over a range of 0.85–1.1 Us AC; 0.9–1.1 Us DC, drawing 6 VA at 240 V and 2 W at 240 V. Because the supply span is wide, a single part can cover several control voltages, though the lowest figure on the span is the practical minimum for a dependable pick-up. The datasheet immunity to microbreaks is 5 ms.
The output is a relay stage with 2 C/O timed contacts, AgNi (cadmium free), rated for 5A at up to 250 V AC/DC, with a minimum switching current of 100 mA. Electrical durability is listed as 100000 cycles and mechanical durability as 30000000 cycles.
Mounting, terminals and environment for the RE48AML12MW
The body is 48 mm wide and weighs 0.14 kg. The datasheet lists these mounting options: Base mounted: socket; Panel mounted: system supplied with the product.
Protection degrees are listed as IP40 (housing) conforming to IEC 60529; IP50 (front face) conforming to IEC 60529. Humidity tolerance is 93 % without condensation conforming to IEC 60068-2-3. Vibration resistance is 0.35 mm (f= 10–55 Hz) conforming to IEC 60068-2-6. Operation is listed over -20–50 °C and storage over -40–70 °C. Inside a closed Gulf enclosure in summer the air around a timer sits well above room temperature, so leave space around RE48AML12MW and keep it away from contactor coils and drives.
Technical specifications of the RE48AML12MW
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / RE48AML12MW |
| Range of product | Harmony Timer Relays |
| Product type | Panel-mounted/plug-in timer relay |
| Component name | RE48A |
| Number of functions | 4 |
| Output type | Relay |
| Contacts | 2 C/O timed contacts, AgNi (cadmium free) |
| Rated supply voltage [Us] | 24–240 V AC/DC |
| Power consumption | 6 VA at 240 V; 2 W at 240 V |
| Maximum switching current | 5A |
| Repeat accuracy | ± 0.2 % of the maximum setting value conforming to IEC 61812-1 |
| Setting accuracy | ± 5 % of full scale at 25 °C conforming to IEC 61812-1; ± 10 % of full scale at 25 °C conforming to IEC 61812-1 |
| Control type | Selector switch front panel; Without test button |
| Status indication | 1 LED (yellow) for output relay state; LED indicator (green) for flashing: relay energised timing in progress; LED indicator (green) for on steady: relay energised, no timing in progress |
| Electrical durability | 100000 cycles |
| Mechanical durability | 30000000 cycles |
| Width | 48 mm |
| Mounting | Base mounted: socket; Panel mounted: system supplied with the product |
| Net weight | 0.14 kg |
| Product certifications | UL; cULus; CSA; C-Tick |
| IP degree of protection | IP40 (housing) conforming to IEC 60529; IP50 (front face) conforming to IEC 60529 |
| Operating temperature | -20–50 °C |
| Relative humidity | 93 % without condensation conforming to IEC 60068-2-3 |
| Warranty | 18 months |
Where the RE48AML12MW is used in Oman and the GCC
In Omani and wider GCC plants a timer of this type is typically chosen for general-purpose timing on panels where one device must cover several jobs, from start delays to pulses and flashers, keeping a single spare type that can replace several fixed-function relays and retrofits where the exact timing mode is only decided during commissioning. Oil and gas skids, power auxiliaries, desalination and water treatment packages and general industrial panels all use this class of device, and the combination of heat, dust and humidity makes sealed enclosures and clean terminal work important. Where timing is part of a safety function, the project specification and a suitable safety device take precedence over a general-purpose timer.
Timing functions and time ranges of the RE48AML12MW
This unit lists the following timing functions, each named by its datasheet code.
- A: Power on-delay. The timing period begins when the supply is applied, and the output changes state only after it has run out.
- B: Single interval started by a control signal. One timed output pulse is produced each time the control input acts.
- C: Off-delay started by a control signal. The output closes with the control input and holds for the set time after it is released.
- Di: Symmetrical flashing that starts with the output on, with equal on and off periods.
The setting covers 0.02 s to 300 h in total, split across these ranges: 0.02 to 1.2 s; 0.05 to 3 s; 0.2 to 12 s; 0.5 to 30 s; 2 to 120 s; 5 to 300 s; 0.2 to 12 min; 0.5 to 30 min; 2 to 120 min; 5 to 300 min; 0.2 to 12 h; 0.5 to 30 h; 2 to 120 h; 5 to 300 h. The datasheet gives a setting accuracy of ± 5 % of full scale at 25 °C conforming to IEC 61812-1; ± 10 % of full scale at 25 °C conforming to IEC 61812-1 and a repeat accuracy of ± 0.2 % of the maximum setting value conforming to IEC 61812-1, with drift of ± 0.02 %/°C of the maximum setting value conforming to IEC 61812-1 against temperature and ± 0.2 %/V of the maximum setting value at 48–240 V; ± 1 %/V of the maximum setting value at 24–48 V against supply voltage. Pick the range whose upper end is closest above the time you need, because accuracy is quoted as a share of full scale.
Selection and installation checklist for the RE48AML12MW
- Function: confirm the timing mode (A, B, C, Di) against the sequence diagram on the datasheet.
- Time: choose a range between 0.02 s to 300 h with the upper limit just above your set point.
- Supply: 24–240 V AC/DC, with the wiring and source verified before energising.
- Output: 2 changeover contacts, checked against the real load current and voltage.
- Fit: 48 mm wide, with the mounting type matching the panel.
- Front panel: Selector switch front panel; Without test button.
Isolate and prove dead before wiring, mount this unit, connect the supply and output terminals, set the function and range, then run the sequence with a test load before the plant is released. Re-check the set time after any change to supply voltage or ambient conditions, and keep a record of the final setting on the panel drawing.
The RE48AML12MW among Harmony timer relays
Width, output type, supply span and function set separate the references. The table compares this unit with its closest neighbours from the same lane.
| Part number | Functions | Width | Supply | Output | Time span |
|---|---|---|---|---|---|
| RE17RMMU | 10 functions | 17.5 mm | 24–240 V AC / 24 V DC | 1 changeover contact | 0.1 s to 100 h |
| RE22R1MLMR | 4 functions | 22.5 mm | 24–240 V AC/DC | 1 changeover contact | 0.05 s to 300 h |
| RE22R1MYMR | 18 functions | 22.5 mm | 24–240 V AC/DC | 1 changeover contact | 0.05 s to 300 h |
| RE22R2MMU | 10 functions | 22.5 mm | 24–240 V AC / 24 V DC | 2 changeover contacts | 0.1 s to 100 h |
| RE22R2MMW | 10 functions | 22.5 mm | 12–240 V AC/DC | 2 changeover contacts | 0.1 s to 100 h |
| RE48AML12MW (this page) | 4 functions | 48 mm | 24–240 V AC/DC | 2 changeover contacts | 0.02 s to 300 h |
Information to send with an RFQ for the RE48AML12MW
- Exact reference RE48AML12MW and the quantity.
- Required timing function and set time.
- Control supply voltage and whether AC or DC.
- Load type and current on the output.
- Any matching socket, base or accessory needed.
- Delivery location and required date.
Documents and quotation
The Schneider Electric datasheet for the RE48AML12MW is attached on this page and carries the full specification and function diagrams. Its date is 7 Nov 2026, as printed on the manufacturer’s document, so check the status of the part before ordering.
Send the reference RE48AML12MW, quantity and delivery location and Seven Star LLC will reply to your request. We supply as an independent supplier based in Muscat and do not act for the manufacturer.
Other Models in the Se Timer Relay Range
Seven Star LLC supplies models from the Se Timer Relay range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric RE17LAMW Harmony Timer Relay | Contactors & Overload Relays | View details |
| Schneider Electric RE17LCBM Harmony Timer Relay | Contactors & Overload Relays | View details |
| Schneider Electric RE22R1CMR Harmony Timer Relay | Contactors & Overload Relays | View details |
| Schneider Electric RE22R1KMR Harmony Timer Relay | Contactors & Overload Relays | View details |
| Schneider Electric RE22R1MAMR Harmony Timer Relay | Contactors & Overload Relays | View details |
| Schneider Electric RE48AML12MW Harmony Timer Relay | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric RE48AML12MW Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric RE48AML12MW Harmony Timer Relay
Answers from our engineering team on installation, compatibility and integration.
01What timing function does the RE48AML12MW provide?
The datasheet lists 4 functions: A (Power on-delay relay); B (Single interval relay w/ control signal); C (Off-delay relay w/ control signal); Di (Symmetrical flashing relay (starting pulse-on)).
02What time range can be set on the RE48AML12MW?
The total span is 0.02 s to 300 h, split into 14 ranges: 0.02 to 1.2 s; 0.05 to 3 s; 0.2 to 12 s; 0.5 to 30 s; 2 to 120 s; 5 to 300 s; 0.2 to 12 min; 0.5 to 30 min; 2 to 120 min; 5 to 300 min; 0.2 to 12 h; 0.5 to 30 h; 2 to 120 h; 5 to 300 h. Setting accuracy is +/- 5 % of full scale at 25 °C conforming to IEC 61812-1; +/- 10 % of full scale at 25 °C conforming to IEC 61812-1.
03What supply voltage does the RE48AML12MW need?
The datasheet gives a rated supply of 24...240 V AC/DC over 0.85...1.1 Us AC; 0.9...1.1 Us DC. The unit is 48 mm wide.
04What kind of output does the RE48AML12MW have?
A relay output with 2 C/O timed contacts, AgNi (cadmium free). The listed maximum switching current is 5A.
05How is the RE48AML12MW mounted?
The datasheet lists these mounting options: Base mounted: socket; Panel mounted: system supplied with the product. The unit is 48 mm wide.