Schneider Electric CAD50GD TeSys D Relay 5NO 125V DC
Description
CAD50GD TeSys D control relay: what the part number tells you
The CAD50GD is a Schneider Electric TeSys D control relay: Control relay, TeSys Deca, 5NO, up to 690V, 125 VDC standard coil, screw clamp terminals. In plain terms it is a contactor-style relay with five normally open contacts, designed for control circuits rather than motor power, and its coil is rated 125 V DC. Seven Star LLC supplies the CAD50GD in Oman and the GCC as an independent supplier based in Muscat.
Reading the code against the datasheet: CAD is the TeSys D control relay series, 50 gives the 5 NO contact arrangement (five poles in both cases), and the ending GD stands for the 125 V DC coil that the datasheet lists for this reference. Neighbouring references differ only in the coil voltage or type, so the complete code decides whether the relay will fit your control supply.
Technical specifications of the CAD50GD
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / CAD50GD |
| Range / type | TeSys Deca control relay (TeSys CAD) |
| Pole contact composition | 5 NO |
| Utilisation categories | DC-13; AC-14; AC-15 |
| Rated operational voltage (Ue) | ≤ 690 V AC 25 to 400 Hz |
| Control circuit voltage (Uc) | 125 V DC |
| Control voltage limits | 0.1 to 0.25 Uc (-40 to 70 °C):drop-out DC; 0.7 to 1.25 Uc (-40 to 60 °C):operational DC; 1 to 1.25 Uc (60 to 70 °C):operational DC |
| Operating time | 53 to 72 ms coil energisation and NO closing; 16 to 24 ms coil de-energisation and NO opening |
| Inrush / hold-in power | 5.4 W (at 20 °C) / 5.4 W at 20 °C |
| Thermal current (Ith) | 10 A (at 60 °C) |
| Rated making capacity | 140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1 |
| Associated fuse | 10 A gG conforming to IEC 60947-5-1 |
| Insulation voltage (Ui) | 690 V IEC 60947-5-1; 600 V UL and CSA |
| Mechanical durability / rate | 30 Mcycles / 180 cyc/mn |
| Mounting / terminals | DIN rail or plate; screw clamp 1 to 4 mm², 1.7 N.m |
| Dimensions (H x W x D) | 77 mm x 45 mm x 93 mm |
| Net weight | 0.58 kg |
| Degree of protection | IP2X front face conforming to VDE 0106 |
| Ambient temperature, operation | -40 to 60 °C; 60 to 70 °C with derating |
| Ambient temperature, storage | -60 to 80 °C |
| Certifications | CB; CCC; UL; CSA; EAC; CE; UKCA |
Coil, operating window and supply sizing for the CAD50GD
The coil is the one part that distinguishes the CAD50GD from its siblings, so it deserves the closest reading.
The 125 V DC coil is the sibling for plants and utilities whose station battery is rated 125 V rather than 110 V, a convention that follows North American practice and turns up on oil and gas sites supplied by international contractors. Matching the coil to the nominal battery voltage keeps the operating window centred on the real supply. The datasheet lists the same 5.4 W standard coil power, which at 125 V is about 43 mA.
That window runs from 0.7 to 1.25 Uc, about 87.5 to 156 V on this coil, so it tolerates both a discharged battery and a boost-charged one. The drop-out band of 0.1 to 0.25 Uc is about 12.5 to 31 V. Because the relay has five normally open poles and no normally closed ones, it is used where one signal has to be repeated to many circuits, for example a generator or compressor trip fanning out to alarm, shutdown and indication, and not where a normally closed contact is needed.
Calculated from the datasheet, the 125 V DC coil of the CAD50GD has an operational window of 87.5 to 156 V (0.7 to 1.25 Uc), and it drops out at 12.5 to 31.2 V (0.1 to 0.25 Uc). The datasheet gives 5.4 W for inrush and for hold-in, which corresponds to about 43.2 mA at pull-in and when held in at the nominal voltage. These are indicative figures worked out from the stated power and voltage, and they are meant for supply sizing, not as guaranteed current ratings.
Contact arrangement of the CAD50GD: five normally open contacts
The 5 NO configuration is the version for pure signal multiplication. With no normally closed contacts, all five poles close when the coil is energised, so a single command can start, indicate and permit several circuits at once. The datasheet lists operating times only for the normally open contacts, as there are no normally closed contacts to describe.
Choose it when a single initiating contact, for example a PLC output or a protection relay trip contact, has to be repeated on five independent circuits: alarm annunciation, a shutdown loop, a remote indication, an interlock to another panel and a counter or logger. If any of those circuits needs a contact that opens when the relay operates, the 3 NO + 2 NC member of the family is the right choice instead.
Contact data from the datasheet apply to all five poles: 10 A conventional thermal current at 60 °C, utilisation categories AC-15, AC-14 and DC-13, a rated operational voltage up to 690 V AC, and a minimum switching capability of 17 V and 5 mA, which makes the contacts suitable for low-level signals as well as for 24 V PLC inputs.
Where the CAD50GD sits in the CAD50 family
The CAD50GD is one member of a family of TeSys D control relays that share the housing, the contact data and the mounting. Only the coil voltage and type change from one reference to the next, together with the contact arrangement: the CAD32 series is 3 NO + 2 NC and the CAD50 series is 5 NO. The table lists the CAD50 references we are asked for most.
If the supply is not in the table, ask us; the CAD32 series has the other contact arrangement. AC-coil versions are 84 mm deep and DC-coil versions 93 mm, which matters in a shallow enclosure.
| Reference | Coil voltage and type | Contacts |
|---|---|---|
| CAD50B7 | 24 V AC 50/60 Hz | 5 NO |
| CAD50BD | 24 V DC standard | 5 NO |
| CAD50BL | 24 V DC low consumption | 5 NO |
| CAD50E7 | 48 V AC 50/60 Hz | 5 NO |
| CAD50FD | 110 V DC standard | 5 NO |
| CAD50GD (this page) | 125 V DC standard | 5 NO |
| CAD50MD | 220 V DC standard | 5 NO |
| CAD50P7 | 230 V AC 50/60 Hz | 5 NO |
| CAD50U7 | 240 V AC 50/60 Hz | 5 NO |
Selection checklist for the CAD50GD
- Coil: 125 V DC, confirmed from the supply drawing or the nameplate of the relay being replaced.
- Contacts: five normally open contacts, matched to the interlock and signalling circuits.
- Supply sizing: about 43.2 mA continuously, because the datasheet gives the same power for inrush and hold-in (derived figure).
- Window: operates within 87.5 to 156 V (0.7 to 1.25 Uc) and releases at 12.5 to 31.2 V (0.1 to 0.25 Uc).
- Contact load of the CAD50GD: 10 A thermal, AC-15, AC-14 or DC-13 duties; use a contactor for motor-power loads.
- Space: 77 mm high, 45 mm wide and 93 mm deep.
- Environment: operation up to 60 °C, up to 70 °C with derating; storage -60 to 80 °C.
Mounting, wiring and service life of the CAD50GD
Mount the CAD50GD on a 35 mm DIN rail or on a plate; the datasheet lists both. It measures 77 mm x 45 mm x 93 mm and weighs 0.58 kg, so allow space for the wires to bend at the terminals and for air to circulate around the housing. Tighten the screw-clamp terminals to 1.7 N.m with a Philips No 2, Pozidriv No 2 or 6 mm flat screwdriver, and do not exceed the cable sizes of 1 to 4 mm² per terminal listed in the datasheet.
Commissioning is simple: energise the coil at nominal voltage, verify that all five poles move together, and check the contact action with a meter before connecting the field loads. The mechanical durability is 30 million cycles and the maximum operating rate is 180 cycles per minute, so in normal control duty there is no routine wear item to schedule. In a dusty site, clean the panel and check terminal tightness during planned shutdowns, because loose terminals, more often than the relay itself, cause intermittent faults.
Where the CAD50GD is used in Oman and the GCC
A 110, 125 or 220 V DC coil is a substation and power-plant part. In the utilities, desalination plants and large industrial sites of the region, the station battery feeds protection and control, and a multiplying relay of this kind repeats trip, alarm and interlock signals inside switchgear panels and relay rooms. It is a natural spare for outage planning, because panel relays at that voltage are hard to buy quickly when a shutdown is under way.
For the CAD50GD, that means five normally open contacts from one 125 V DC command, sitting next to LC1D contactors of the same TeSys D family on the same rail.
Information to send with an RFQ for the CAD50GD
- Full reference CAD50GD and the quantity
- The coil voltage and type seen on the supply drawing or on the old relay nameplate
- The load or circuit each contact will switch (voltage, current, signal level)
- Panel or machine the relay must fit, and whether it is a spare, a replacement or a new installation
- Delivery location in Oman or the GCC and the date required
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above, and it is worth reading beside the panel drawing before you order.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Other Models in the Se Cad50 Range
Seven Star LLC supplies models from the Se Cad50 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric CAD50B7 TeSys D Relay 5NO 24V AC | Contactors & Overload Relays | View details |
| Schneider Electric CAD50BD TeSys D Relay 5NO 24V DC | Contactors & Overload Relays | View details |
| Schneider Electric CAD50BL TeSys D Relay 5NO 24VDC Low Power | Contactors & Overload Relays | View details |
| Schneider Electric CAD50E7 TeSys D Relay 5NO 48V AC | Contactors & Overload Relays | View details |
| Schneider Electric CAD50FD TeSys D Relay 5NO 110V DC | Contactors & Overload Relays | View details |
| Schneider Electric CAD50GD TeSys D Relay 5NO 125V DC | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric CAD50GD Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric CAD50GD TeSys D Relay 5NO 125V DC
Answers from our engineering team on installation, compatibility and integration.
01What coil does the CAD50GD have?
The datasheet lists a 125 V DC standard DC coil. The operational window is 87.5 to 156 V and drop-out is 12.5 to 31.2 V.
02How many contacts does the CAD50GD have?
It has five normally open contacts, with a 10 A conventional thermal current at 60 °C and utilisation categories AC-15, AC-14 and DC-13.
03How much power does the coil of the CAD50GD draw?
The datasheet gives 5.4 W for inrush and for hold-in. At 125 V that is about 43.2 mA both at pull-in and held in, derived from the stated power.
04What are the dimensions and weight of the CAD50GD?
77 mm high, 45 mm wide and 93 mm deep, with a net weight of 0.58 kg. It mounts on a DIN rail or a plate.
05What ambient temperature does the CAD50GD accept?
Operation is listed from -40 to 60 °C, and up to 70 °C with derating; storage is -60 to 80 °C. Altitude is 0 to 3000 m.