Schneider Electric LRD21 TeSys Deca Overload Relay 12-18 A
Description
LRD21 TeSys Deca thermal overload relay: what it is and how the code reads
The LRD21 is a Schneider Electric product described in the datasheet as: TeSys Deca, thermal overload relay, 12 to 18 A, class 10A. The LRD family is the TeSys Deca differential thermal overload relay line, fitted below a contactor to protect a motor against sustained overcurrent and phase loss. Seven Star LLC supplies the LRD21 in Oman and the GCC as an independent supplier based in Muscat.
Decoding the reference: LRD is the TeSys Deca thermal overload relay series and the number (21) selects the current setting band; for this reference the datasheet gives an adjustment range of 12 to 18 A with Class 10A IEC 60947-4-1. A relay in a neighbouring band has a different range, so select the band so that the motor full-load current falls in the upper half of the setting range where possible.
Technical specifications of the LRD21
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / LRD21 |
| Description | TeSys Deca, thermal overload relay, 12 to 18 A, class 10A |
| Range | TeSys; TeSys Deca |
| Product name | TeSys LRD; TeSys Deca |
| Product type | Differential thermal overload relay |
| Device short name | LRD |
| Application | Motor protection |
| Thermal protection adjustment range | 12 to 18 A |
| Thermal overload class | Class 10A IEC 60947-4-1 |
| Network type | AC; DC |
| Network frequency | 0 to 400 Hz |
| Product compatibility | LC1D32; LC1D18; LC1D25; LC1D38 |
| Tripping threshold | 1.14 ± 0.06 Ir IEC 60947-4-1 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Control type | Red push-button stop; Blue push-button reset |
| Temperature compensation | -20 to 60 °C |
| Rated operational voltage (Ue) | 690 V AC 0 to 400 Hz power circuit IEC 60947-4-1 |
| Rated impulse withstand (Uimp) | 6 kV |
| Associated fuse rating (signalling) | 4 A gG for signalling circuit; 4 A BS for signalling circuit |
| Power circuit terminals | Power circuit screw clamp terminals 1 1.5 to 10 mm² flexible without cable end; Power circuit screw clamp terminals 1 1 to 4 mm² flexible with cable end; Power circuit screw clamp terminals 1 1 to 6 mm² solid |
| Dimensions | 45 mm (W) x 66 mm (H) x 70 mm (D) |
| Net weight | 0.124 kg |
| Degree of protection | IP20 conforming to IEC 60529 |
| Operating temperature | -20 to 60 °C without derating IEC 60947-4-1 |
| Mounting support | Plate, with specific accessories; Rail, with specific accessories; Under contactor |
How the LRD21 protects the motor
A thermal overload relay uses bimetallic elements heated by the motor current. When the current stays above the set value long enough, the elements bend and operate the auxiliary contacts, which open the contactor coil circuit. The LRD21 is a differential type, which means it also trips faster when the phase currents are unbalanced; the datasheet states for phase failure: Tripping current 130 % of Ir on two phase, the last one at 0.
The trip class describes how quickly the relay trips under a standard overload multiple. The datasheet states Class 10A IEC 60947-4-1 for the LRD21. Class 10A suits normal starts; motors with long run-up times such as large fans or high-inertia loads can trip nuisance-wise on a class 10A relay and need a slower class or an electronic relay.
Where the LRD21 fits in a starter
The LRD21 is mounted directly under a compatible contactor; the datasheet lists compatibility with LC1D32; LC1D18; LC1D25; LC1D38. The 95/96 NC contact is wired into the contactor control circuit and the 97/98 NO contact signals the trip to a PLC. Red stop and blue reset push-buttons are fitted on the front as listed in the datasheet.
Related bands in the same family include LRD08, LRD10, LRD14, LRD32, which cover successive current ranges. Use the datasheet of the exact reference to check that the contactor frame and the setting range suit the motor.
Selection and ordering checklist for the LRD21
- Set the dial to the motor full-load current from the nameplate; the LRD21 covers 12 to 18 A.
- Check that the contactor is among those the datasheet lists (LC1D32; LC1D18; LC1D25; LC1D38).
- Confirm trip class (Class 10A IEC 60947-4-1) against the motor start time.
- Decide on manual or automatic reset policy in the control circuit.
- Check conductor size against the listed terminal capacity and torque, and the operating temperature range -20 to 60 °C without derating IEC 60947-4-1.
- If heavy starting or sensitive protection is needed, consider an electronic overload relay instead.
Installation, commissioning and maintenance of the LRD21
Mount the relay on the contactor lower terminals, tighten the power terminals to the torque in the datasheet and set the current dial. Test the trip and reset function once before commissioning with the test button. The device is 45 mm (W) x 66 mm (H) x 70 mm (D) and weighs 0.124 kg, so it fits easily in a standard starter row.
During operation, a relay that trips often is giving a signal: check the motor load, the supply voltage balance and ambient temperature before raising the setting. Do not increase the dial above the motor rating to avoid trips. Inspect terminals at planned shutdowns and keep the front window clean so the dial setting can be read.
Typical applications of the LRD21 in Oman and the GCC
The LRD21 protects pumps, fans, compressors and conveyors in motor control centres in oil and gas facilities, water and wastewater works, desalination units and industrial plants across Oman and the GCC. In hot switchrooms the ambient compensation range in the datasheet, -20 to 60 °C, is relevant when checking the setting.
Information to send with an RFQ for the LRD21
- Full reference LRD21 and quantity
- Motor full-load current and voltage
- Contactor reference it will be mounted under
- Required trip class and reset method
- Delivery location and timing
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.
Other Models in the Se Lrd Range
Seven Star LLC supplies models from the Se Lrd range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric LRD10 TeSys Deca Overload Relay 4-6 A | Contactors & Overload Relays | View details |
| Schneider Electric LRD21 TeSys Deca Overload Relay 12-18 A | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric LRD21 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric LRD21 TeSys Deca Overload Relay
Answers from our engineering team on installation, compatibility and integration.
01What current range does the LRD21 cover?
The datasheet lists a thermal protection adjustment range of 12…18 A.
02Which contactors can the LRD21 be mounted under?
The datasheet lists compatibility with LC1D32; LC1D18; LC1D25; LC1D38. Check the datasheet for the complete list.
03What trip class is the LRD21?
The datasheet states Class 10A IEC 60947-4-1, intended for standard motor start times.
04Does the LRD21 protect against phase loss?
Yes. The datasheet lists phase failure sensitivity: Tripping current 130 % of Ir on two phase, the last one at 0.
05How is the LRD21 reset?
It has a blue push-button reset and a red stop button on the front, as listed under control type in the datasheet.