- Automation & ControlView all 1,692 products
- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Isolator & Barrier
- Industrial Computers
- Servo Drives
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Automation Software
- Machine Vision
- Robotics
Brand: Lovato Electric
Lovato DMG600 Flush-Mount Three-Phase LCD Multimeter
Description
DMG600 multifunction power analyser: decoded part number
The DMG600 is a flush-mount digital multimeter from Lovato Electric with a backlit icon LCD display for monitoring electrical systems. It gives true RMS values of voltage, current, power, energy and harmonics, and can be expanded with plug-in EXP modules for communication or I/O.
Decoded: DMG is the Lovato multimeter family, and 600 is the expandable flush-mount model with a 72 x 46 mm display. The non-expandable DMG110 and the DMG200 are family members with different housings and options.
Technical specifications of the DMG600
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Lovato Electric / DMG600 |
| Type | Flush-mount LCD multimeter, expandable; three-phase plus neutral |
| Auxiliary supply | 100 to 440 V AC; 120 to 250 V DC |
| Operating range | 90 to 484 V AC; 93.5 to 300 V DC; 45 to 66 Hz |
| Consumption | 9.5 VA maximum; 3.5 W |
| Voltage inputs | 600 V L-L, 300 V L-N rated; 50 to 720 V L-L operating |
| Current inputs | 1 A / 5 A via CT; measurement range 0.025 to 6 A |
| Overload | +20 % constant; 50 A peak for 1 s |
| Measurement method | True RMS |
| Accuracy | Voltage and current ±0.5 %; frequency ±0.05 %; active power ±0.5 % |
| Energy classes | Active class 1 (IEC/EN 62053-21); reactive class 2 (IEC/EN 62053-23) |
| Harmonic analysis | Up to the 15th order |
| Display | Backlit icon LCD, 72 mm x 46 mm active area |
| Insulation | Ui 600 V; Uimp 9.5 kV |
| Terminals | Removable; 0.2 to 2.5 mm²; 0.5 Nm |
| Protection | IP54 front; IP20 terminals |
| Operating temperature | -20 °C to +60 °C |
| Weight | 300 g |
Values are taken from the Lovato Electric catalogue entry for DMG600. The catalogue entry lists no built-in serial port on this model; communication is through expansion modules.
How the DMG600 works
The multimeter samples voltages and currents and calculates true RMS values, power, energy and harmonic content in real time. Current inputs are connected through external current transformers with 1 A or 5 A secondary, and the voltage inputs are connected directly up to 600 V line-to-line or through voltage transformers for medium-voltage systems.
The unit displays measured values on the front through icon-based screens and can store energy counters. Because the front has an optical port, a technician can configure it from a PC or app without touching the wiring.
With the EXP expansion modules, the meter can add communication ports, relay outputs or other functions; check the module list in the catalogue for the supported combinations.
Fit in the system and related Lovato Electric parts
The DMG600 fits at the incomer or a feeder of a low-voltage board, where it complements a power factor controller such as the DCRL3 and the current transformers of the same manufacturer.
- DMG110 and DMG200 for simpler or modular metering
- DMG610 and DMG8000 for higher functionality
- Current transformers of the DM0T range
- EXP series expansion modules for communication and I/O
Selection and ordering checklist for the DMG600
Before ordering the DMG600, settle the following points so that the right variant is quoted:
- System type: single-, two- or three-phase with or without neutral
- Voltage level and whether voltage transformers are needed
- CT ratio and secondary 1 A or 5 A
- Supply voltage: 100 to 440 V AC or 120 to 250 V DC
- Need for communication, I/O or energy pulses
Installation, commissioning and maintenance of the DMG600
Cut out the panel door, insert the meter from the front and fix it with the supplied clips; connect the supply, voltage inputs and CT secondaries with the correct polarity and phase. Never open a CT secondary circuit while the primary is carrying current.
After power-up set the CT ratio, VT ratio and system type through the keypad or the optical port, and compare readings with a reference instrument.
- Check CT shorting terminals and wiring after commissioning
- Clean the front glass
- Verify energy counters during audits
- Save the configuration file
Typical applications in Oman and the GCC
Multimeters are used at motor control centres, generator incomers, compressor stations and utility switchboards to give operators and energy managers a view of load and power quality. The 15th-order harmonic analysis is useful near variable-speed drives, which are common in Gulf pumping and desalination plants.
Because the meter is rated up to +60 °C, it is suitable for panels in unconditioned electrical rooms, but its front should be protected from direct sun on outdoor kiosks.
When you request a quotation for the DMG600, note that the unit measures through external current transformers. If the existing CTs are of 1 A or 5 A secondary class and have enough burden for the added meter, they can be reused; if not, new CTs are needed. Also tell us whether the readings must go to a SCADA system, because the catalogue entry shows no built-in communication port and an expansion module would then be part of the order. For energy audits, remember that active energy accuracy is class 1 and reactive class 2 under the standards listed, which is adequate for internal cost allocation but not for tariff metering.
Variants related to the DMG600
Related meters in the Lovato Electric catalogue:
| Code | Type | Remark |
|---|---|---|
| DMG600 | Flush-mount, expandable | This variant |
| DMG110 | Modular, non-expandable | Other family |
| DMG200 | Digital multimeter, 4-module DIN | Other family |
| DMG610 | Flush-mount multimeter | Other family |
Information to send with an RFQ for the DMG600
To quote the DMG600 quickly, please send:
- Part number DMG600
- Quantity
- System and voltage level
- CT ratio and secondary
- Auxiliary supply
- Delivery destination and date
Site conditions in Oman for the DMG600
Electrical rooms and outdoor panels in the Gulf often operate well above the 25 °C reference temperature used in many catalogues. Before you finalise the DMG600, compare the expected panel temperature with the operating range and any output derating stated in the manufacturer documentation, and leave the recommended clearance above and below the device for convection. Supply quality also varies between sites, so confirm the input voltage range, frequency and any requirements for protection on the supply side.
Where the device feeds or monitors critical loads, plan how faults will be signalled to the control system and how a replacement can be installed quickly. Keeping one spare DMG600 per site and recording its settings helps maintenance teams in Oman restore service with minimum downtime.
Documents and quotation
No datasheet file is attached to this page. Send us the part number and we will confirm which official documents are available for your application.
For a quotation on the DMG600, send the part number or article number, quantity and the delivery destination in Oman or the GCC. Seven Star LLC is an independent supplier based in Muscat and confirms availability and lead time per request.
Reviews (0)
How would you rate this product? Cancel reply
About brand
Lovato Electric is the Italian manufacturer of low-voltage electrical components for industrial automation and power distribution: contactors, motor protection circuit breakers, soft starters, variable speed drives, power factor controllers, transfer switch and generator controllers, and energy meters. It was founded in Bergamo in 1922 and has been run by the same family for four generations. Its headquarters is in Gorle, near Bergamo, and it celebrated its centenary in 2022.
Seven Star LLC is an independent supplier in Muscat. We list Lovato motor control, drives and power management products, and supply them to panel builders, contractors and maintenance teams in Oman and the GCC by order code.
Lovato Electric at a glance
| Established | 1922, Bergamo, Italy |
|---|---|
| Headquarters | Gorle (Bergamo), Italy |
| Ownership | Private, family-run for four generations |
| Product families | Contactors and relays, motor protection circuit breakers, motor starters, soft starters, variable speed drives, power factor controllers, ATS and gen-set controllers, multimeters and energy meters, micro PLCs |
Lovato products we list
| Family | Models | Typical use |
|---|---|---|
| Contactors | BF0910A230, BF1810A230, BF2510A230, BF2600A230, BF09T4A230 4-pole, BFS0923A024, 11BG0910A230 mini, 11BGR0901A048 reversing | Switching motors, heaters, lighting and capacitor banks |
| Motor protection and starters | SM1P0650, SM1P1000, SM1P3200, M1P enclosed DOL starter, ME024FD024, ME070RSD024, 31L48 time relay | Short-circuit and overload protection and direct starting of motors |
| Soft starters | ADXL0030600, ADXL0085600, ADXL0135600, ADXT0034, ADXT0084, ADXT0139 | Reducing starting current and mechanical shock on pumps, fans and compressors |
| Variable speed drives | VLA1, VLB1, VLB3 0.75 kW, VLB3 2.2 kW, VLB3 5.5 kW, VLB3 22 kW, VT1 | Speed control of pumps, fans and conveyors to save energy |
| Power management and control | DCRG8, DCRL8 PF controllers, ATL600 ATS controller, RGK600 gen-set controller, DMG200 multimeter, DMED300T2 energy meter, LRD20 micro PLC | Power factor correction, mains/generator changeover and energy monitoring |
Lovato order codes describe the product. On a contactor such as BF0910A230, "BF09" is the frame and rated current (9 A in AC-3), "10" is the built-in auxiliary contact (one normally open), "A" means an AC coil and "230" is the coil voltage. The coil voltage must match the control circuit exactly, so it is the most common detail to check when replacing one. For motors, a soft starter limits the inrush current at start and stop, while a variable speed drive controls the speed continuously and saves energy on pumps and fans that do not need full flow all the time.
Where Lovato products are used
In Oman and the GCC, Lovato components are built into motor control centres, pump and HVAC panels, capacitor banks for power factor correction, generator and ATS panels, and machine control panels for industry, water and buildings.
Ordering Lovato products: what we need
Send the full Lovato order code. For contactors and starters, confirm the coil or control voltage. For drives and soft starters, send the motor power, current and supply voltage. For power factor controllers, send the number of steps and the CT ratio.
Facts checked against Lovato Electric company profile brochures, October 2026.
Browse Lovato Electric products by category: Motor Soft Starters, Automation Accessories, Controllers & Data Acquisition, PLC & I/O Cards, Circuit Breakers, Diesel Generator Spare Parts.
FAQ
Questions about the Lovato DMG600 Flush-Mount Three-Phase LCD Multimeter
Answers from our engineering team on installation, compatibility and integration.
01What does the DMG600 measure?
It measures voltage, current, frequency, power and energy on single-phase, two-phase and three-phase systems with or without neutral, with true RMS measurement, and gives harmonic analysis up to the 15th order.
02What supply does it need?
An auxiliary supply of 100 to 440 V AC or 120 to 250 V DC, with a consumption of 9.5 VA maximum.
03What accuracy does it have?
Voltage and current ±0.5 %, frequency ±0.05 %, active power ±0.5 %, active energy class 1 and reactive energy class 2.
04How is it mounted?
It is flush-mounted in a panel cut-out, with IP54 protection on the front and removable terminals at the rear.
05Can it be expanded?
Yes, the catalogue lists it as an expandable multimeter that accepts EXP modules; it has a front optical port.


















Reviews