Pfannenberg DTT 6201 230V SC Top-Mount Cooling Unit, 1 kW

Description

DTT 6201 230V SC cooling unit: decoded part number

The DTT 6201 230V SC is a roof-mounted cooling unit of 1 kW class from Pfannenberg. It sits on top of the enclosure and cools the cabinet interior through cut-outs in the roof, leaving the doors and side panels free for access, for cable entries and for other equipment.

Decoded: DTT = top-mounted cooling unit, 6201 = installation size and performance class, 230V = single-phase supply and SC = Standard Controller. The order number is 13256241055.

Technical specifications of the DTT 6201 230V SC

Parameter Specification
Manufacturer / part number Pfannenberg / DTT 6201 230V SC
Cooling capacity (EN 14511) 1000 W at 50 Hz and 1100 W at 60 Hz (A35/A35); 600 W and 640 W (A35/A50)
Supply 230 V AC 1~ ±10 %, 50 / 60 Hz
Power consumption (A35/A35) 663 W at 50 Hz; 805 W at 60 Hz
EER 1.51 at 50 Hz; 1.37 at 60 Hz
Pre-fuse gG, 10 A
Airflow (free flow) Internal 570 m³/h; external 1820 m³/h
Noise level 62 dB(A) and below 62 dB(A) (50 / 60 Hz)
Controller Standard Controller
Refrigerant R134a, 400 g
Ambient temperature +15 °C to +55 °C
Setpoint range +25 °C to +50 °C, adjustable
Protection IP54 towards the enclosure; IP34 towards the surroundings; NEMA Type 12
Housing Galvanised sheet steel, powder-coated cover, RAL 7035
Dimensions (H x W x D) 451 mm x 588 mm x 393 mm
UL file number SA10300

Values are from the product page for article 13256241055. Starting-current figures differ between page and sheet, so they are not quoted.

How the DTT 6201 230V SC works

The unit has a closed refrigeration circuit. The evaporator side draws cabinet air up through the roof opening, cools it and sends it back down, while the condenser side carries heat away on a separate air path above the cabinet roof. Because the refrigerant circuit is hermetic, the enclosure keeps its protection class.

Condensate is handled by a patented management system that the manufacturer describes as giving four-fold protection against condensate, with an integrated evaporation system and a safety overflow. The manufacturer also states a quick-installation frame that allows tool-less mounting and a front cover that can be removed completely for service access to filter mats and controls.

The noise level of 62 dB(A) is typical for a compressor unit of this size; keep it in mind for control rooms with permanently staffed workplaces.

Fit in the system and related Pfannenberg parts

The DTT 6000 series spans three installation sizes and six performances, 500 to 1080 W according to the sheet, so the 6201 is the larger of two sub-series next to the 6101.

  • SC 230 V, article 13256241055 (this unit)
  • Multi-controller version, 230 V: article 13256271055
  • Other DTT 6201 supplies: 400 V 2-phase SC 13256249055; 115 V 60 Hz SC 13256244055
  • Smaller DTT 6101: 230 V SC 13256141055

Selection and ordering checklist for the DTT 6201 230V SC

Before ordering the DTT 6201 230V SC, settle the following points so that the right variant is quoted:

  • Heat load and target temperature; capacity at +50 °C ambient is 600 to 640 W
  • Roof space for a 588 mm x 393 mm unit and the necessary clear air for the external circuit
  • Supply voltage and phase: 230 V single-phase
  • Controller type SC or MC and whether a filter mat is needed
  • Finish: V2A stainless-steel version available for some variants

Installation, commissioning and maintenance of the DTT 6201 230V SC

Top-mounted units are fitted on a roof cut-out using the quick-installation frame. Make sure that the roof can carry the weight and that there is clear space above and around the unit so that the external air can flow freely; blocked louvres are a common cause of high-pressure trips.

Start-up consists of connecting the plug, setting the temperature, and checking that the condensate runs away through the integrated evaporation system. Check that the cabinet is closed and that all unused cut-outs are blanked.

  • Inspect the optional filter mats and condenser area regularly
  • Verify condensate evaporation after prolonged operation in humid conditions
  • Check for blocked air path above the roof
  • Use qualified refrigeration personnel for service of the sealed circuit

Typical applications in Oman and the GCC

Top-mounted units are used where side walls are crowded: stand-alone control cabinets, containerised switchgear, instrument shelters and machine-control cabinets in refineries, compressor stations and desalination plants. Because warm air collects at the top of a cabinet, a roof position is a natural point to extract it.

In hot regions the relevant figure is the capacity at A35/A50, which is 600 to 640 W; plan the heat balance accordingly, and consider shade or a canopy for cabinets standing in direct sun.

Variants related to the DTT 6201 230V SC

Variants shown by the manufacturer for DTT 6201 and 6101:

Article Controller / supply Series
13256241055 SC, 230 V AC DTT 6201 – this variant
13256271055 MC, 230 V AC DTT 6201
13256249055 SC, 400 V 2~ DTT 6201
13256244055 SC, 115 V 60 Hz DTT 6201
13256141055 SC, 230 V AC DTT 6101

Information to send with an RFQ for the DTT 6201 230V SC

To quote the DTT 6201 230V SC quickly, please send:

  • Part number DTT 6201 230V SC and article 13256241055
  • Quantity and controller type
  • Supply voltage
  • Heat load and ambient design conditions
  • Roof size and free space above the cabinet
  • Delivery destination and date

Site conditions in Oman for the DTT 6201 230V SC

Panel cooling in Oman is sized for the worst case, not the average day. Summer shade temperatures in Muscat, Sohar and the interior regularly pass 45 °C, and a cabinet standing in direct sun gains further heat through its walls. When you size the DTT 6201 230V SC, add the internal losses of drives, power supplies and PLCs to the solar and wall gain, and compare the total with the useful cooling capacity at your real ambient and target cabinet temperature, rather than with a nominal figure stated at milder test conditions.

Coastal sites near Duqm, Salalah or Sur also bring humidity and salt-laden dust. Keep door seals intact, route the condensate drain away from live parts, and plan routine filter and coil cleaning so that the DTT 6201 230V SC keeps its rated performance through the long summer season.

Documents and quotation

A product sheet for the DTT 6201 and 6101 series is attached on this page, with capacity data, article numbers and accessory table.

For a quotation on the DTT 6201 230V SC, send the part number or article number, quantity and the delivery destination in Oman or the GCC. Seven Star LLC is an independent supplier based in Muscat and confirms availability and lead time per request.

Datasheets & Documents
  • PDF Datasheet Pfannenberg DTT 6201 230V SC Product Sheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pfannenberg is the German maker of thermal management and signalling products for electrical enclosures and industry: filter fans, cooling units, air-to-water heat exchangers, chillers, heaters, sirens and beacons. Otto Pfannenberg, an electrical engineer, founded the company in Hamburg in 1954, and in 1958 he invented the filter fan to stop components in control cabinets from overheating. Pfannenberg is still family-owned and headquartered in Hamburg.

Seven Star LLC is an independent supplier in Muscat. We list Pfannenberg signalling devices and enclosure climate products for panel builders and plant engineers in Oman and the GCC.

Pfannenberg company profile

Founded 1954, Hamburg, Germany
Founder Otto Pfannenberg, electrical engineer
Headquarters Hamburg, Germany; North American headquarters in Lancaster, New York
Ownership Family-owned
Product families PF Filterfans, DTS and DTI cooling units, air-to-water heat exchangers, process chillers, enclosure heaters and thermostats, PA and DS sirens, beacons and combined signalling devices

Milestones

  • 1954: Otto Pfannenberg founds the company in Hamburg.
  • 1958: Pfannenberg invents the filter fan for control cabinets.
  • 1962: The company introduces an industrial flashing light that does not need a bulb change after activation.

Pfannenberg product series

Signalling devices include the PATROL PA X combined flashing sounders from 105 to 122 dB(A), the PYRA flashing light sounder, the PRO 10-Ex sounder for zone 2 and zone 22, and the INTENSE BR 50 modular LED signal tower.

Thermal management covers FLZ enclosure thermostats, twin thermostats, hygrostats and Peltier thermostats, FLH radiant heaters and PFH and FLH-T fan heaters, PF filter fans in several installation sizes up to 785 m3/h and the PTF roof-mounted filter fan, and DTS and DTI cooling units, including the DTI outdoor version.

Where Pfannenberg products are used

Control and drive cabinets on machines and in plant rooms, outdoor enclosures in hot and humid climates, and alarm and evacuation signalling in industrial buildings and process areas. In the Gulf, cabinet cooling and condensation control are the main reasons for specifying Pfannenberg thermal products.

Pfannenberg products we list

Family Examples
Enclosure Climate Control FLH 060 Radiant Enclosure Heater, FLH-T 600 Fan Heater with Integrated, FLZ 510 Enclosure Thermostat, FLZ 541 Twin Thermostat, FLZ 600 Hygrostat for Control Cabinets, FLZ 700 Peltier Unit Thermostat, PFH 650 Compact Fan Heater
Fire & Gas Detectors INTENSE BR 50 Modular LED Signal Tower, PA X 1-05 PATROL Flashing Sounder 105 dB(A), PA X 20-10 PATROL Flashing Sounder 122 dB(A), PA X 5-05 PATROL Flashing Sounder 107 dB(A), PRO 10-Ex Explosion-Proof Sounder 116 dB(A), PY X-MA-05 PYRA Flashing Light Sounder 101
Cooling DTI 8401P Outdoor Cooling Unit, DTS 3061 Cooling Unit, PF 22.000 DC Filterfan, PF 66.000 Filterfan, PTF 60.500 Roof-Mounted Filterfan

Ordering Pfannenberg products: what we need

Send the article number or full designation, such as PA X 1-05 or DTI 8401P. For signalling devices add the supply voltage, lens and housing colour and any required approval such as EN 54-3 or an Ex certificate. For cooling units give the cooling capacity, voltage and frequency, mounting (side or roof, internal or external) and the ambient temperature. For fans and heaters give the installation size, voltage and airflow or heating power.

Facts checked against Pfannenberg's published company history, October 2026.

FAQ

Questions about the Pfannenberg DTT 6201 230V SC Top-Mount Cooling

Answers from our engineering team on installation, compatibility and integration.

01Where is the DTT 6201 mounted?
It is a top-mounted unit that sits on the roof of the cabinet, so no wall or door space is used. This is the main difference from the DTS and DTI side-mounted units.
02What is its cooling capacity?
The product page gives 1000 W at 50 Hz and 1100 W at 60 Hz, and 600 W and 640 W at A35/A50 conditions, according to EN 14511.
03What noise level does it have?
The page lists 62 dB(A) and below 62 dB(A) at 50 and 60 Hz.
04How does it handle condensate?
It uses an integrated condensate evaporation system with a safety overflow; the sheet describes a four-fold protection against condensate.
05What are its dimensions?
The page lists 451 mm high, 588 mm wide and 393 mm deep.