- Automation & ControlView all 1,738 products
- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Isolator & Barrier
- Encoders
- Industrial Computers
- Servo Drives
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Automation Software
- Machine Vision
- Robotics
Brand: Pfannenberg
Pfannenberg DTI 6401 230V MC Recessed Cooling Unit, 2 kW
Description
DTI 6401 230V MC cooling unit: decoded part number
The DTI 6401 230V MC is a 2000 W Green Series cooling unit for partially recessed mounting in a cabinet door or side wall, with the Multi Controller. Because part of the housing lies inside the cut-out, the projection is reduced compared with the outer-mounted DTS version, which matters in narrow aisles and containers.
Decoded: DTI = partially recessed mounting, 6401 = 2 kW Green Series model, 230V = single-phase 230 V supply and MC = Multi Controller. The order number is 13899421055.
Technical specifications of the DTI 6401 230V MC
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Pfannenberg / DTI 6401 230V MC |
| Cooling capacity (EN 14511) | 2000 W at A35/A35; 1500 W at A35/A50 |
| Supply | 230 V AC 1~ ±10 %, 50 / 60 Hz |
| Power consumption (A35/A35) | 931 W at 50 Hz; 1126 W at 60 Hz |
| Current consumption | 6.9 A |
| Starting current | 21.8 A |
| Energy efficiency ratio (EER) | 2.15 at 50 Hz; 1.78 at 60 Hz |
| Pre-fuse | gG, 10 A |
| Controller | Multi-Controller |
| Refrigerant | R134a, 500 g |
| Ambient temperature | +10 °C to +55 °C |
| Setpoint range | +25 °C to +45 °C, adjustable |
| Protection | IP55 towards the enclosure; IP24 towards the surroundings; NEMA Type 12 |
| Dimensions (H x W x D) | 1537 mm x 485 mm x 278 mm; installation depth 120 mm |
| Colour and housing | RAL 7035; galvanised sheet steel, powder-coated cover |
Values are from the product page for article 13899421055. Airflow figures differ in layout between the sheet and the page and are therefore not quoted.
How the DTI 6401 230V MC works
This is the same closed-loop refrigeration technology as the outer-mount DTS 6401, packaged for recessed installation. The compressor circuit cools and dehumidifies internal air, and a separate external air path carries the heat away. A condensate evaporator handles moisture, and a safety overflow is provided.
The Multi Controller adds data features compared with the standard controller; together with the service port it can be read by the εCOOL-Plant software to display operating data and fault history.
Because the unit is recessed, the enclosure must have a free internal space of about 120 mm in the mounting area; internal equipment must not obstruct the air outlet or inlet.
Fit in the system and related Pfannenberg parts
The DTI 6401 is the recessed alternative to the outer-mount DTS 6401 and has the same performance class. For smaller loads the 6201C and for bigger ones the 6X2E series come into play.
- SC version, 230 V: article 13899411055
- MC version, 400 / 460 V: article 13899422055
- Outer-mount DTS 6401 230 V MC: article 13889421055
- Stainless-steel V2A versions are listed for several variants, for example 13899421015
Selection and ordering checklist for the DTI 6401 230V MC
Before ordering the DTI 6401 230V MC, settle the following points so that the right variant is quoted:
- Heat load, target temperature and worst-case ambient (1500 W at A35/A50)
- Door or side-wall cut-out dimensions and 120 mm of free interior depth behind it
- Supply 230 V single-phase, 10 A protection
- Controller type and remote-data requirements
- Finish: powder-coated or stainless-steel V2A
Installation, commissioning and maintenance of the DTI 6401 230V MC
Cut out the door or wall according to the manufacturer drawing and seal the unit against the panel so that the stated enclosure-side protection is achieved. The unit is heavy, so use suitable lifting equipment and check that the door hinges can carry the load if the unit is mounted on a door.
After wiring and closing the cabinet, start the unit and check the temperature setpoint, fan rotation and condensate path. Review the controller for alarms after a few hours.
- Clean condenser and filter at regular intervals
- Verify door seals and cut-out gasket annually
- Review the parameter history through the service port
- Have refrigerant checks done by qualified personnel
Typical applications in Oman and the GCC
Recessed cooling units are common on machine builders’ cabinets, packaged skids and containerised power rooms where the outward projection of an outer-mounted unit would be a problem. A 2 kW class cools drive and PLC panels, battery cabinets and instrument racks in desert and coastal sites.
In practice the choice between a DTI and DTS comes down to the wall: recessing frees floor space outside but demands interior space, so confirm what is behind the cut-out before ordering.
Variants related to the DTI 6401 230V MC
Variants of the 6401 range shown by the manufacturer:
| Article | Type | Supply |
|---|---|---|
| 13899421055 | DTI partially recessed, MC | 230 V AC – this variant |
| 13899411055 | DTI partially recessed, SC | 230 V AC |
| 13899412055 | DTI partially recessed, SC | 400 / 460 V AC |
| 13899422055 | DTI partially recessed, MC | 400 / 460 V AC |
| 13889421055 | DTS side mount, MC | 230 V AC |
Information to send with an RFQ for the DTI 6401 230V MC
To quote the DTI 6401 230V MC quickly, please send:
- Part number DTI 6401 230V MC and article 13899421055
- Quantity
- Supply voltage and frequency
- Heat load and ambient design temperature
- Cut-out and interior space available at the mounting position
- Delivery destination and date
Site conditions in Oman for the DTI 6401 230V MC
Panel cooling in Oman is sized for the worst case, not the average day. Summer shade temperatures in Muscat, Sohar and the interior regularly pass 45 °C, and a cabinet standing in direct sun gains further heat through its walls. When you size the DTI 6401 230V MC, add the internal losses of drives, power supplies and PLCs to the solar and wall gain, and compare the total with the useful cooling capacity at your real ambient and target cabinet temperature, rather than with a nominal figure stated at milder test conditions.
Coastal sites near Duqm, Salalah or Sur also bring humidity and salt-laden dust. Keep door seals intact, route the condensate drain away from live parts, and plan routine filter and coil cleaning so that the DTI 6401 230V MC keeps its rated performance through the long summer season.
Documents and quotation
A product sheet for the DTI/DTS 6401 Green Series is attached on this page, with capacity data, article numbers, accessories and capacity curves.
For a quotation on the DTI 6401 230V MC, send the part number or article number, quantity and the delivery destination in Oman or the GCC. Seven Star LLC is an independent supplier based in Muscat and confirms availability and lead time per request.
Datasheets & Documents
- Datasheet Pfannenberg DTI 6401 230V MC Product Sheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pfannenberg is the German maker of thermal management and signalling products for electrical enclosures and industry: filter fans, cooling units, air-to-water heat exchangers, chillers, heaters, sirens and beacons. Otto Pfannenberg, an electrical engineer, founded the company in Hamburg in 1954, and in 1958 he invented the filter fan to stop components in control cabinets from overheating. Pfannenberg is still family-owned and headquartered in Hamburg.
Seven Star LLC is an independent supplier in Muscat. We list Pfannenberg signalling devices and enclosure climate products for panel builders and plant engineers in Oman and the GCC.
Pfannenberg company profile
| Founded | 1954, Hamburg, Germany |
|---|---|
| Founder | Otto Pfannenberg, electrical engineer |
| Headquarters | Hamburg, Germany; North American headquarters in Lancaster, New York |
| Ownership | Family-owned |
| Product families | PF Filterfans, DTS and DTI cooling units, air-to-water heat exchangers, process chillers, enclosure heaters and thermostats, PA and DS sirens, beacons and combined signalling devices |
Milestones
- 1954: Otto Pfannenberg founds the company in Hamburg.
- 1958: Pfannenberg invents the filter fan for control cabinets.
- 1962: The company introduces an industrial flashing light that does not need a bulb change after activation.
Pfannenberg product series
Signalling devices include the PATROL PA X combined flashing sounders from 105 to 122 dB(A), the PYRA flashing light sounder, the PRO 10-Ex sounder for zone 2 and zone 22, and the INTENSE BR 50 modular LED signal tower.
Thermal management covers FLZ enclosure thermostats, twin thermostats, hygrostats and Peltier thermostats, FLH radiant heaters and PFH and FLH-T fan heaters, PF filter fans in several installation sizes up to 785 m3/h and the PTF roof-mounted filter fan, and DTS and DTI cooling units, including the DTI outdoor version.
Where Pfannenberg products are used
Control and drive cabinets on machines and in plant rooms, outdoor enclosures in hot and humid climates, and alarm and evacuation signalling in industrial buildings and process areas. In the Gulf, cabinet cooling and condensation control are the main reasons for specifying Pfannenberg thermal products.
Pfannenberg products we list
Ordering Pfannenberg products: what we need
Send the article number or full designation, such as PA X 1-05 or DTI 8401P. For signalling devices add the supply voltage, lens and housing colour and any required approval such as EN 54-3 or an Ex certificate. For cooling units give the cooling capacity, voltage and frequency, mounting (side or roof, internal or external) and the ambient temperature. For fans and heaters give the installation size, voltage and airflow or heating power.
Facts checked against Pfannenberg's published company history, October 2026.
Browse Pfannenberg products by category: Enclosure Climate Control, Fire & Gas Detectors, Cooling.
FAQ
Questions about the Pfannenberg DTI 6401 230V MC Recessed Cooling Unit,
Answers from our engineering team on installation, compatibility and integration.
01What does DTI mean?
DTI is the partially recessed version of the 6401 cooling unit. It sits in a cut-out of the door or side wall, so only part of the housing projects outside.
02What is the installation depth?
The product page gives an installation depth of 120 mm, with outer dimensions of 1537 mm x 485 mm x 278 mm.
03How does MC differ from SC?
MC is the Multi Controller. For this unit the page states the controller type as Multi-Controller and the series offers a service port for reading parameters and history.
04What is the cooling capacity?
2000 W at A35/A35 and 1500 W at A35/A50 to EN 14511.
05What are the EER values?
The page lists EER 2.15 at 50 Hz and 1.78 at 60 Hz at A35/A35, which indicates the efficiency of cooling per watt of electrical input.


















Reviews