OPTIBAR PM 5060 metallic-diaphragm process pressure transmitter and its building blocks

The KROHNE OPTIBAR PM 5060 is a modular process pressure transmitter with a welded metallic diaphragm. It measures gauge or absolute pressure of gases, liquids and steam, and, through the pressure of a liquid column, hydrostatic level in open tanks. A dual-sensor arrangement enables electronic differential pressure measurement in closed vessels. Measuring ranges cover 100 mbar up to 1000 bar, and the step response is below 85 ms, so the device suits both slow tank duties and fast pump or compressor protection loops.

The product is a modular platform rather than one fixed part. The sensor, process connection, electronics and housing are chosen independently, then combined at order. Three measuring-cell designs are used: a piezoresistive cell for ranges up to 40 bar, a strain gauge cell above 40 bar, and a metallic-ceramic cell for small ranges up to 25 bar or higher temperatures. The same transmitter can also be fitted to the KROHNE OPTIBAR DSP diaphragm seals, which extend it to media up to about +400 °C and to aggressive, viscous or crystallising products.

Technical specifications of the OPTIBAR PM 5060

Parameter Specification
Manufacturer / part number KROHNE / OPTIBAR PM 5060 (C)
Measuring range 100 mbar to 1000 bar (1.45 to 14,500 psi)
Measuring cells Piezoresistive up to 40 bar; strain gauge above 40 bar; metallic-ceramic up to 25 bar
Reference accuracy Classes 0.075%, 0.10% and 0.20% of set span, depending on range and connection
Response time Step response below 85 ms
Process temperature Up to +150 °C depending on seal and version; with diaphragm seal up to +400 °C
Output 2-wire 4-20 mA with HART 7; Foundation Fieldbus and Profibus PA available
Supply voltage 9.6 to 35 V DC for non-Ex devices
Wetted materials 316L process connection; 316L diaphragm; Elgiloy diaphragm from 100 bar; Alloy C-276 for metallic-ceramic cell
Process connections G1/2 male, 1/2 NPT male and female, other threads; hygienic flush connections; DN50 to DN100 flange with diaphragm seal
Housings Plastic (PBT), aluminium, stainless steel precision cast or electro-polished; up to IP68 and IP69K versions
Safety and approvals Ex ia, Ex d and Ex t approvals listed; SIL 2/3 by TÜV Rheinland per the product page

Accuracy, temperature effect and long-term stability tables in the datasheet depend on the accuracy class, measuring range and turn-down ratio, so quote the span you need.

How the OPTIBAR PM 5060 senses pressure

Process pressure acts on a welded metal diaphragm. In the piezoresistive version it is passed through a transfer fluid to a silicon sensor whose resistance changes with pressure. From 100 bar the cell uses a thin-film strain gauge element directly on the back of an Elgiloy diaphragm, so no fill fluid is required. The metallic-ceramic cell has a metal isolating diaphragm and ceramic sensor that tolerates temperature better at low ranges. Relative cells vent to atmosphere and compensate ambient pressure, while absolute cells are evacuated and reference vacuum.

Electronic differential pressure is possible when a slave sensor is added; the datasheet notes that differential pressure, density and interface measurements are available only in that configuration. For process measurement the electronics provide a built-in display and adjustment module with four push buttons, an integrated real-time clock, and Bluetooth setup via the OPTICHECK Pressure Mobile app. PACTware with DTM, HART handhelds, AMS and PDM are also supported.

Where the OPTIBAR PM 5060 fits and related KROHNE pressure transmitters

Use the PM 5060 for demanding process lines, pump protection, compressor monitoring, supply-pressure surveillance and level in tanks where a metallic diaphragm is preferred over ceramic. For clean liquids and abrasive or wear-prone use, the OPTIBAR PC 5060 uses a ceramic capacitive cell, and the OPTIBAR DP 7060 covers high-performance differential pressure. Compact alternatives are the OPTIBAR PM 3050 and PSM 2010, the latter already listed on our site. Where a long cooling leg or high temperature is needed, specify the PM 5060 with an OPTIBAR DSP diaphragm seal.

Selection and ordering checklist for the OPTIBAR PM 5060

  • Measuring task: gauge, absolute, level or electronic differential pressure.
  • Required span and turn-down, and the accuracy class needed.
  • Process medium, maximum temperature, and whether a diaphragm seal or cooling is required.
  • Process connection and thread standard, or flush hygienic connection.
  • Wetted materials, including diaphragm and gasket (FKM, EPDM, FFKM or FEPM).
  • Fill fluid, including FDA-grade or oxygen-service options where relevant.
  • Housing type, protection class and display.
  • Signal protocol (HART, Foundation Fieldbus or Profibus PA) and hazardous-area approval.

Installation, commissioning and maintenance

Mount the transmitter at a position where the process connection is free of blockage, and preferably vertical with the diaphragm pointing down, since the datasheet accuracy refers to that orientation. A position-dependent zero offset can be corrected at commissioning. For steam, use a siphon or syphon loop and a shut-off valve so the diaphragm does not see live steam temperature, and protect outdoor units from direct sun. Tighten metric and non-metric threads to the torque values in the manual, and use the supplied gasket.

Commissioning is done with the display module, the Bluetooth app or a DTM. Set the range and damping, zero the unit at atmosphere for gauge devices, and check the loop current. Maintenance is usually limited to inspecting the process port for deposits and verifying zero. Long-term drift is specified for each cell type, so annual checks suffice in most plants.

Typical applications in Oman and the GCC

The PM 5060 suits water and wastewater plants, desalination feed and reject lines, chemical dosing, power-plant auxiliary systems, lube and fuel oil lines, and compressor stations. Marine and port installations are another listed industry. In hot Gulf conditions it is wise to shade the housing and keep cable glands sealed against dust, and humid coastal sites suit the stainless steel housing or IP68 versions. For fiscal or safety loops, state the SIL need at order, because some options are not compatible with SIL qualification.

Cell types at a glance

Cell Range Notes
Piezoresistive Up to 40 bar Internal transfer fluid; synthetic or FDA-grade oil
Strain gauge Above 40 bar up to 1000 bar Dry system, Elgiloy diaphragm from 100 bar
Metallic-ceramic Up to 25 bar Alloy C-276 diaphragm; better for low ranges and higher temperature

Information to send with an RFQ for the OPTIBAR PM 5060

  • Medium, pressure range, maximum pressure and temperature.
  • Gauge, absolute or differential measurement and required span.
  • Process connection, material and diaphragm seal needs.
  • Housing, display, signal protocol and hazardous-area approval.
  • Quantity and any special documentation.

Documents and quotation

A KROHNE technical datasheet for the OPTIBAR PM 5060 C is attached on this page. Send the details above and we will confirm availability and prepare a quotation for the OPTIBAR PM 5060 in Oman and the GCC as an independent supplier in Muscat.

Other Models in the Krohne Optibar Range

Seven Star LLC supplies models from the Krohne Optibar range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
KROHNE OPTIBAR PM 5060 Metallic Diaphragm Pressure TransmitterPressure InstrumentationYou are viewing this model
KROHNE OPTIBAR DP 7060 Differential Pressure TransmitterPressure InstrumentationView details
Datasheets & Documents
  • PDF Datasheet KROHNE OPTIBAR PM 5060 C Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

KROHNE is the German flow and level measurement company founded in Duisburg in 1921 as Ludwig Krohne & Sohn. Its first customers were Ruhr steel producers, for whom it built variable area flowmeters. KROHNE dates the first electromagnetic flowmeter for industrial process measurement to 1952. It is still family-owned and headquartered in Duisburg.

Seven Star LLC is an independent supplier in Muscat. We list KROHNE electromagnetic, Coriolis, ultrasonic and variable area flowmeters, radar level transmitters and flow computers, and supply them to water utilities, oil and gas and process plants in Oman and the GCC by order code.

KROHNE company profile

Established 1921, Duisburg, Germany, as Ludwig Krohne & Sohn
Early products Variable area flowmeters for hardening furnaces in the Ruhr steel industry
Milestone 1952: first electromagnetic flowmeter for industrial process measurement, according to KROHNE
Product families Electromagnetic, Coriolis, ultrasonic, vortex and variable area flowmeters, radar and guided radar level, flow computers and metering systems, analysers

Milestones

  • 1921: Ludwig Krohne starts making variable area flowmeters in Duisburg for hardening furnaces in the Ruhr steel industry.
  • 1952: First electromagnetic flowmeter for industrial process measurement, according to KROHNE.
  • 1980: First ultrasonic flowmeter delivered to Shell for crude oil measurement.
  • 1985: Development and production of Coriolis mass flowmeters begins.
  • 1994: First Coriolis mass flowmeter with a single straight measuring tube.
  • 1996: ALTOSONIC V, the first ultrasonic meter for custody transfer of liquids.

KROHNE products we list

Family Models Typical use
Electromagnetic flowmeters OPTIFLUX 2000, 2100, 2300, 4100, 4300, WATERFLUX 3070, 3100, 3300 Water networks, wastewater, seawater intake and conductive process liquids
Coriolis mass flowmeters OPTIMASS 1400, 6400 Direct mass flow and density of hydrocarbons, chemicals and LPG
Ultrasonic flowmeters ALTOSONIC V12, OPTISONIC 3400, 6300 clamp-on, 7300 gas Gas custody transfer, liquid process flow and non-intrusive clamp-on checks
Variable area flowmeters H250 M40, DK800/R Simple, power-free flow indication for purge, sample and utility lines
Level OPTIFLEX 7200 guided radar, OPTIWAVE 5400, 7500, 1540, OPTISWITCH 5300 Level in tanks, separators and chemical storage, and point level switching
Flow computer SUMMIT 8800 Fiscal and custody transfer calculations for gas and liquid metering

The flowmeter principle follows the medium. Electromagnetic meters need a conductive liquid, have no moving parts and no pressure loss, and suit water and slurries. Coriolis meters measure mass flow and density directly, so they work for hydrocarbons and non-conductive liquids. Ultrasonic meters handle gas and large pipes, and multi-path designs such as the ALTOSONIC V12 are used for custody transfer. Variable area meters need no power at all and give a simple local reading.

Where KROHNE instruments are used

In Oman and the GCC, KROHNE flowmeters and level transmitters are used in water transmission and distribution, desalination, wastewater, oil and gas production and fiscal metering, refineries, petrochemical and chemical plants, and power stations.

Ordering KROHNE instruments: what we need

Send the complete KROHNE order code or the nameplate data. For a new meter, send the medium, the flow range, pressure and temperature, the pipe size and flange rating, the liner and electrode materials (for electromagnetic meters), the output and communication, and the hazardous area classification.

Facts checked against KROHNE company history (100th anniversary), October 2026.

FAQ

Questions about the KROHNE OPTIBAR PM 5060 Metallic Diaphragm Pressure

Answers from our engineering team on installation, compatibility and integration.

01What pressure range does the OPTIBAR PM 5060 cover?
Measuring ranges run from 100 mbar up to 1000 bar, using a piezoresistive cell to 40 bar, a strain gauge cell above that and a metallic-ceramic cell for small ranges up to 25 bar.
02How fast is it?
The datasheet quotes step response times below 85 ms, which makes it usable for pump dry-run protection and compressor monitoring as well as slower tank level duties.
03Can it be used with diaphragm seals?
Yes. It can be combined with KROHNE OPTIBAR DSP diaphragm seals for aggressive, viscous or hot media. The product page lists the diaphragm seal version up to +400 degrees C.
04Which communication options are available?
The standard configuration is 2-wire 4-20 mA with HART 7. Foundation Fieldbus and Profibus PA versions are available, and a Bluetooth app can be used for setup and verification.
05Is it different from the OPTIBAR PC 5060?
Yes. The PM 5060 uses a welded metallic diaphragm, while the PC 5060 uses a ceramic capacitive cell. Metallic suits higher pressures and hygienic flush connections, ceramic suits wear resistance and vacuum overload.