- Automation & ControlView all 1,667 products
- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Industrial Computers
- Servo Drives
- Isolator & Barrier
- HMI Displays
- Motor Soft Starters
- Pneumatic Cylinders
- Automation Software
- Machine Vision
- Robotics
Brand: WIKA
WIKA S-11 Flush Diaphragm Pressure Transmitter
Description
WIKA S-11 flush diaphragm pressure transmitter for viscous and particle-laden media
The WIKA S-11 is a pressure transmitter with a flush, welded stainless steel diaphragm, made for media that would block the pressure channel of a conventional threaded connection. WIKA lists viscous, paste-like, adhesive, crystallising, particle-laden and contaminated media, with food and beverage, filling and packing machinery, dosing technology and level measurement as typical fields. The process connection is G 1/2 B or G 1 B flush, with a hygienic G 1 B version and an optional cooling element for medium temperatures to 150 °C. Seven Star LLC supplies the S-11 in Oman and the GCC as an independent supplier in Muscat; this page explains the S-11 type options and the points that most often decide an RFQ.
Why a flush diaphragm matters on the S-11
On a standard transmitter the medium enters a small pressure port and reaches the sensor. Sludge, polymers, syrups, crystallising solutions or fibre can settle in that port, dry out and give false readings. In the S-11 the diaphragm sits flush with the process wall; the connections are fully welded and isolate the medium from the measuring element by positive seal, so there is no dead space and the wetted diaphragm can be cleaned together with the process. The internal pressure transmission uses synthetic oil, or, for food and beverage use, a system fill fluid per FDA 21 CFR 178.3750. The hygienic G 1 B connection is in 316L and the instrument carries 3-A marking for that connection, verified by a third party.
Technical specifications of the S-11
| Parameter | Specification |
|---|---|
| Manufacturer / part number | WIKA / S-11 |
| Measuring ranges (gauge) | 0 … 0.1 bar to 0 … 600 bar [0 … 15 to 0 … 6,000 psi] |
| Absolute and vacuum | 0 … 0.25 to 0 … 16 bar abs.; vacuum and compound ranges from -1 bar |
| Vacuum tightness | Yes |
| Output signals | 4 … 20 mA (2-wire); 0 … 20 mA (3-wire); DC 0 … 10 V; DC 0 … 5 V |
| Accuracy at reference conditions | ≤ ±0.5 % of span standard; ≤ ±0.25 % optional (ranges from 0.25 bar) |
| Non-linearity (BFSL) | ≤ ±0.2 % of span |
| Non-repeatability | ≤ 0.1 % of span |
| Long-term stability | ≤ ±0.2 % of span per year |
| Settling time | ≤ 2 ms |
| Power supply | 4 … 20 mA: DC 10 … 30 V; DC 0 … 10 V: DC 14 … 30 V |
| Process connection | G 1/2 B flush; G 1 B flush; hygienic G 1 B flush (3-A) |
| Wetted parts | 316Ti (G 1/2 B and G 1 B); 316L (hygienic G 1 B) |
| Medium temperature | -30 … +100 °C, optional +125 °C; -20 … +150 °C with cooling element |
| Ingress protection | IP65 (DIN 175301-803 A), IP67 (M12 x 1 or cable), IP68 (cable outlet) |
Seals, connections and temperatures for the S-11
The seal material limits pressure and temperature. Without a cooling element and up to 100 °C, NBR is standard and good to 600 bar, FKM/FPM to 600 bar and EPDM to 200 bar; at 125 °C, FKM falls to 400 bar. With the cooling element (to 150 °C), FKM/FPM is limited to 300 bar and EPDM to 200 bar. The hygienic G 1 B connection is delivered with EPDM and limited to 200 bar and 150 °C. An FFKM O-ring for the G 1/2 B flush connection is optional with a 600 bar limit at all temperatures. G 1 B flush covers 0 … 0.1 to 0 … 1.6 bar and the hygienic G 1 B version 0 … 0.1 to 0 … 25 bar, while G 1/2 B flush covers 0 … 2.5 to 0 … 600 bar.
Electrical connections are angular connector DIN 175301-803 A (IP65), M12 x 1 four-pin circular connector (IP67), a cable outlet IP67 or an IP68 cable outlet in lengths of 1.5, 3, 5, 10 or 15 m. Zero and span can be adjusted by internal potentiometers by ±5 %, except on the IP68 cable outlet. The device is protected against short circuit, reverse polarity and overvoltage of DC 36 V.
Where the S-11 fits and related WIKA transmitters
WIKA points to the S-20 for general industrial applications with a pressure port, to the IS-3 for hazardous areas and to the HP-2 for very high pressures. The A-10 is the general-purpose version. The S-11 is the one to choose when the process, not the pressure range, decides the connection: sugar, dairy and beverage lines, polymer or paint circuits, wastewater sludge, and slurries. For measurement in plain water or clean oil the S-20 or A-10 is simpler.
Selection and ordering checklist for the S-11
- Medium description: viscosity, solids content, crystallising tendency, cleaning method.
- Pressure range and unit; consider vacuum and absolute options.
- Flush connection: G 1/2 B, G 1 B or hygienic G 1 B (3-A).
- Seal: NBR, FKM/FPM, EPDM or FFKM, matched to medium and temperature.
- Cooling element if the medium exceeds 125 °C.
- Fill fluid: synthetic oil or FDA-compliant system fill fluid.
- Output signal and accuracy class (0.5 % or 0.25 %).
- Electrical connection and IP rating.
Installation, commissioning and maintenance of the S-11
Fit a flush transmitter so the diaphragm is not scratched; never insert tools into the port. Use only the sealing delivered with the instrument and tighten to the torque of the mating thread. The S-11 is calibrated in vertical mounting with the process connection facing downwards, so a different position may shift zero slightly; correct it with the zero potentiometer if the cable outlet allows. When cleaning in place, check the maximum medium temperature of the seal, particularly during steam cycles. Expect a temperature coefficient of up to ±0.2 % of span per 10 K over the 0 … 80 °C rated range (below 0.25 bar, up to 0.4 %). The data sheet quotes a mean time to failure above 100 years.
Typical applications in Oman and the GCC
Typical Gulf uses include date and juice processing, dairy and beverage plants, water treatment sludge lines, desalination brine and chemical dosing, and pulp or paint circuits in industrial zones. In hot sites the cooling element version covers process media up to 150 °C, while the ambient limit of 80 °C is relevant to outdoor panels in direct sun.
S-11 flush connections compared
| Connection | Range covered | Wetted material | Notes |
|---|---|---|---|
| G 1/2 B flush | 0 … 2.5 to 0 … 600 bar | 316Ti | Also with cooling element |
| G 1 B flush | 0 … 0.1 to 0 … 1.6 bar | 316Ti | Also with cooling element |
| Hygienic G 1 B flush | 0 … 0.1 to 0 … 25 bar | 316L | 3-A marked; EPDM seal; 200 bar max. |
Information to send with an RFQ
- S-11 with range, type of pressure and unit
- Flush connection and seal material
- Medium, temperature and cleaning method
- Output signal, accuracy and electrical connection
- Cooling element and fill-fluid needs
- Quantity, delivery site and certificates
Documents and quotation
The WIKA data sheet for the S-11 is attached on this page, with range tables, sealing data and dimensions.
Send the range, connection, seal and medium and Seven Star LLC will confirm availability and a quotation.
Datasheets & Documents
- Datasheet WIKA S-11 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
WIKA is the German manufacturer of pressure, temperature, level and flow instruments, best known for its pressure gauges. Alexander Wiegand and Philipp Kachel founded it on 2 January 1946 in Klingenberg am Main, Bavaria. The name comes from the first two letters of their surnames. WIKA is still run by the Wiegand family and is headquartered in Klingenberg.
Seven Star LLC is an independent supplier in Muscat. We list WIKA pressure gauges, diaphragm seals, transmitters, switches, thermometers and thermowells, and supply them to plants, contractors and panel builders in Oman and the GCC by model and order code.
WIKA company profile
| Established | 2 January 1946, Klingenberg am Main, Germany, by Alexander Wiegand and Philipp Kachel |
|---|---|
| First products | Mechanical pressure and temperature gauges |
| Ownership | Family-owned; managed by Alexander Wiegand, grandson of the founder, since 1996 |
| Product families | Pressure gauges, diaphragm seals, pressure transmitters and switches, thermometers, RTDs, thermocouples, thermowells, calibration equipment, level and flow instruments |
Milestones
- 1946: Alexander Wiegand and Philipp Kachel found the company in Klingenberg am Main on 2 January; pressure gauge production starts at the end of the year. The name WIKA comes from the first letters of their surnames.
- 1951: Konrad Wiegand, the founder's son, takes over management.
- 1967: Ursula Wiegand leads the company after her husband's death.
- 1986: The company is reunited with the Kachel thermometer factory, which Philipp Kachel had set up after leaving in 1956.
- 1994: Certification to DIN ISO 9001.
- 1996: Alexander Wiegand, the founder's grandson, becomes head of the company.
WIKA products we list
| Family | Models | Typical use |
|---|---|---|
| Bourdon tube pressure gauges | 111.10, 111.12, 212.20, 213.53, 232.50, 233.50, 232.30/233.30 safety pattern | HVAC and utilities (111 series) to process plants (23x series in stainless steel) |
| Diaphragm and differential pressure gauges | 432.50, 732.51, 700.01, DPGT43 | Low pressures, viscous or dirty media, and filter differential pressure |
| Diaphragm seals | 990.10, 990.27 | Separating the gauge from corrosive, hot or clogging media |
| Transmitters, switches and test gauges | A-10, UPT-20, PSM01, CPG1500 | 4-20 mA pressure signals, switching, and precision calibration checks |
| Thermometers | TG54, Model 55, A52, 73 gas-actuated | Local temperature indication on pipes, vessels and HVAC |
| Temperature sensors and thermowells | TR10, TR12-B, TR33, TC10-B, TW10 flanged, TW15 threaded | RTD and thermocouple measurement in process lines |
The WIKA model number tells you the build. In 232.50, the first digit 2 means stainless steel wetted parts, the second digit 3 means a liquid-fillable case, and ".50" is the case style. The 111 series uses copper alloy wetted parts and suits water and air. Where the medium is corrosive, very hot or would block the gauge, a diaphragm seal such as the 990.27 keeps it away from the Bourdon tube. For temperature, a thermowell like the TW10 lets you remove the sensor without opening the process.
Where WIKA instruments are used
In Oman and the GCC, WIKA gauges, transmitters and thermometers are used in oil and gas, refining and petrochemical plants, power and desalination, water networks, district cooling and HVAC, and on skids and machines from OEMs.
Ordering WIKA instruments: what we need
Send the model, dial size (for example 63, 100 or 160 mm), range and unit, connection size and position (lower or back mount), accuracy class and whether liquid filling is needed. For diaphragm seals and thermowells, add the process connection, materials and insertion length.
Facts checked against WIKA company history, October 2026.
Browse WIKA products by category: Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the WIKA S-11 Flush Diaphragm Pressure Transmitter
Answers from our engineering team on installation, compatibility and integration.
01What is the WIKA S-11 used for?
It measures pressure of viscous, paste-like, crystallising, particle-laden or contaminated media with a flush diaphragm that does not block, including food and beverage versions.
02What process connections does the S-11 have?
G 1/2 B flush, G 1 B flush and a hygienic G 1 B flush connection marked to 3-A, all welded stainless steel.
03What output signals does the S-11 provide?
4 to 20 mA two-wire, 0 to 20 mA three-wire, 0 to 10 V and 0 to 5 V DC.
04Can the S-11 handle hot media?
Yes. With the integrated cooling element the medium temperature may reach 150 degrees C; without it the limit is 100 degrees C, or 125 degrees C as an option.
05Is there a food-compatible fill fluid?
Yes, an internal system fill fluid per FDA 21 CFR 178.3750 is optional for food and beverage use.


















Reviews