Brand: Magnaflux
Magnaflux 14AM Fluorescent Magnetic Particle Suspension
Description
Ready-to-use fluorescent particle bath for very fine discontinuities
Magnaflux 14AM is a ready-to-use, oil-based fluorescent magnetic particle suspension. It combines the manufacturer’s 14A magnetic particles with Carrier II NDT-approved suspension oil in a prepared bath, designed for locating very fine discontinuities in critical parts. Indications show as bright fluorescent green under UV black light, and the sheet describes it as an ideal choice for precision, safety-critical or high-stress components and for extending the life of valuable mag particle equipment.
The data sheet says 14AM meets major industry and NDT specification requirements, including aerospace, ASTM and ISO 9934, and that it is listed on the QPL SAE AMS 3045-1S and AMS 3046-1S Qualified Product List and approved for use by Pratt and Whitney.
Features and benefits
- Ready to use: 14A particles pre-mixed in Carrier II petroleum distillate
- High sensitivity with minimal background fluorescence
- Slow evaporation and low susceptibility to bacteria or fungus, so baths last longer
- Protects equipment from internal rust and corrosion and eliminates post-inspection corrosion treatment on most alloys
- Optimised particle size and shape to reduce clumping
- Available as aerosol or 5 gal pail liquid
Technical specification
| Parameter | Specification |
|---|---|
| Product type | Oil-based fluorescent magnetic particle suspension |
| NDT method | Magnetic Particle Testing, fluorescent, wet method |
| Particles | 14A |
| Suspension vehicle | Carrier II (petroleum distillate) |
| Appearance | Oily liquid and fine particle solution |
| Colour in visible light | Brown |
| Colour in UV light | Fluorescent yellow-green |
| Odour | Minimal, negligible |
| Particle size range | 5 to 12 micrometres |
| SAE sensitivity | 8 to 9 (indications on a tool steel ring per ASTM E1444) |
| Flash point | Above 200 F / 93 C |
| Settling volume | 0.10 to 0.40 mL |
| Defect location | Surface and slightly subsurface |
| Required equipment | Magnetizing device, UV light source |
| Usage temperature | 42 to 120 F / 6 to 48 C |
| Storage temperature | 50 to 86 F / 10 to 30 C |
| Specifications listed | AMS 2641, ASTM E709, ASTM E1444, ASME, ISO 9934, MIL-STD-2132, MIL-STD-271, NAVSEA 250-1500-1, NAVSEA T9074-AS-GIB-010/271, QPL SAE AMS 3045-1S, QPL SAE AMS 3046-1S |
| Revision | December 2023 |
Ordering and selection guide
| Pack | Part number |
|---|---|
| Aerosol can, case of 12 | 01-0145-78 |
| 5 gal / 18.9 L pail | 01-0145-40 |
Choose the aerosol for field inspections and the pail for a horizontal wet bench, where 14AM replaces the need to mix particles into oil. If you prefer to build a water-based bath from powder, see 20B, which uses the same 14A particles. 14AM is a petroleum distillate suspension and should not be mixed with water.
Preparation, use and bath maintenance
Aerosol cans are used as supplied: shake well, hold 7 to 9 inches (18 to 24 cm) from the part, apply by the continuous or residual method until covered, and inspect under black light. For the liquid, fill the tank to the proper level and mix for at least 15 minutes until the particles are evenly dispersed. Do not add extra Carrier II or mix with water.
The sheet asks for suspension concentration and contamination to be checked at least once a day or as the specification requires, measured by settling volume in an ASTM pear-shaped centrifuge tube. The Magnaflux tube 8493 (100 mL, stem graduated 0 to 1 mL in 0.05 mL steps) is the one recommended. Contaminated or long-used suspensions should be replaced, and parts demagnetised before cleaning.
Applications
Named uses: very fine to fine discontinuities, critical applications, parts after secondary processing, in-service inspections and high-strength alloys. For Gulf operators, that fits rotating-equipment shafts, gear teeth, fasteners and repair welds in compressors and turbines. A UV lamp and a darkened inspection area are required, and the bath should be protected from the heat of open workshops using the 6 to 48 C working range as a guide.
14AM compared with 7HF aerosol
Both products are oil-based wet-method suspensions in Carrier II, and both come in aerosol cans, but they serve different inspection conditions.
| Property | 14AM | 7HF |
|---|---|---|
| Indication | Fluorescent yellow-green under UV | Black in visible light |
| Particle size | 5 to 12 micrometres | Mean below 2 microns |
| SAE sensitivity | 8 to 9 | Above 6 |
| Settling volume | 0.10 to 0.40 mL | 1.20 to 2.40 mL |
| Extra equipment | Magnetizing device and UV light | Magnetizing device |
| Bulk pack | 5 gal pail | Aerosol only |
The printed sensitivity figures come from different test rings (ASTM E1444 for 14AM, ASTM E3024 for 7HF), so they should not be compared as a ranking. Match the product to the procedure and viewing conditions instead.
Planning a fluorescent wet bench with 14AM
A fluorescent bath only gives results when the whole station is in order. Besides the 14AM suspension, the data sheet lists a magnetising device and a UV light source as required equipment, and a darkened inspection area is needed to see the indications. Plan for a settling tube to check the concentration daily, a way to demagnetise parts and a clean tank. The printed usage temperature is 6 to 48 C, so keep the bath and the shop within that window.
Storage and bath records
Keep aerosol cases and pails at 10 to 30 C, in a ventilated area away from heat and strong magnetic fields. Write the fill date, batch number and the daily settling volume on the bath log, together with the black light intensity and the ambient white light reading. The printed settling volume range of 0.10 to 0.40 mL is the figure to compare against, and a bath outside it should be corrected or replaced according to the procedure.
Information needed for a quotation
Send the part number from the table, whether you need the aerosol case or the 5 gal pail, the quantity, the delivery location in Oman or the GCC and any specification the shipment must reference.
Related items
See 20B for the water-bath premix with the same particles, 7HF for visible aerosol, the Y-7 yoke and the Non-Destructive Testing (NDT) category.
Related Magnaflux products: Magnaflux 7HF Oil-Based Visible Magnetic Particle Aerosol, Magnaflux Y-7 AC/DC Electromagnetic Yoke, Magnaflux ZL-67 Level 3 Water Washable Fluorescent Penetrant, Magnaflux ZL-60D Level 2 Water Washable Fluorescent Penetrant, Magnaflux ZP-9F Solvent Based Developer Aerosol and Magnaflux SKC-S Spotcheck NDT Cleaner and Remover.
Documents and quotation
Download the official data sheet from this page and confirm the pack, approvals and revision against your inspection specification. We are an independent supplier in Muscat; send the part number for a quotation.
Datasheets & Documents
- Datasheet Magnaflux 14AM Product Data Sheet (manufacturer PDF, revised December 2023) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnaflux is an American maker of non-destructive testing materials and equipment, best known for magnetic particle and liquid penetrant inspection. The company dates from the 1930s in Chicago, where its engineers helped spread magnetic particle crack detection through industry, and it is now a division of Illinois Tool Works (ITW), headquartered in Glenview, Illinois.
Seven Star LLC is an independent supplier in Muscat. We list Magnaflux consumables and inspection tools for NDT companies, fabrication yards and maintenance workshops in Oman and the GCC.
Magnaflux company profile
| Origin | 1930s, Chicago, Illinois, USA |
|---|---|
| Headquarters | Glenview, Illinois |
| Ownership | Illinois Tool Works (ITW) |
| Methods | Magnetic particle inspection and liquid penetrant inspection |
| Product families | Spotcheck SKL-SP2 penetrants and SKD-S2 developer, Zyglo fluorescent penetrants, 7HF and 14AM magnetic particles, Y-7 and Y-8 yokes, wet horizontal benches, UV-A inspection lamps |
Milestones
- 1930s: Magnaflux is established in Chicago.
- 1945: Magnaflux engineers publish on magnetic particle testing through ASTM.
Magnaflux product series
Penetrant products include the Spotcheck system of SKC-S cleaner and remover, SKL-SP2 visible red dye penetrant and SKD-S2 solvent-based developer, the ZL-60D level 2 and ZL-67 level 3 Zyglo water-washable fluorescent penetrants and the ZP-9F developer aerosol.
Magnetic particle products include the 7HF oil-based visible particle aerosol, the 14AM fluorescent particle suspension and the 20B fluorescent premix, applied with an electromagnetic yoke such as the Y-7 AC/DC yoke.
Where Magnaflux products are used
Weld inspection on pipelines, vessels and structures, shutdown inspections in refineries and plants, incoming inspection of castings and forgings, and aerospace and automotive part inspection to ASTM, ISO and aerospace specifications.
Magnaflux products we list
Ordering Magnaflux products: what we need
Send the product name and package (aerosol, litre or drum), the quantity and the inspection standard or specification you work to. For yokes give the supply voltage and whether AC, DC or both are required.
Facts checked against ASTM records and Magnaflux company profiles, October 2026.
Browse Magnaflux products by category: Penetrant & Magnetic Particle Testing.
FAQ
Questions about the Magnaflux 14AM Fluorescent Magnetic Particle
Answers from our engineering team on installation, compatibility and integration.
01What particles are in 14AM?
Magnaflux 14A fluorescent magnetic particles in Carrier II petroleum distillate.
02What are the printed particle size and sensitivity?
5 to 12 micrometres and SAE sensitivity 8 to 9.
03How often should the bath be checked?
At least once a day, or as the applicable specification requires, using settling volume.
04What is the settling volume range?
0.10 to 0.40 mL.
05Which lists is 14AM on?
QPL SAE AMS 3045-1S and AMS 3046-1S.