Brand: Hydac
Hydac HFS 2156-1W-0020-0060-7-B-1-000 Flow Switch, 60 L/min
Description
A larger oil flow switch with an M12 plug and a change-over contact
The Hydac HFS 2156-1W-0020-0060-7-B-1-000 (HYDAC part number 925574) is the higher-flow, M12 version of the HFS 2100 oil flow switch. It uses the same float and reed-contact principle as its smaller sibling, but this code covers 20 to 60 L/min on a G1 body, and it has one change-over contact rather than a simple normally open one. That lets a controller read both a flow-present and a no-flow signal on one device.
The 6 in the code marks the 4-pole M12x1 plug, which suits compact industrial wiring, with the mating connector ordered separately.
Technical specifications
| Parameter | Specification |
|---|---|
| HYDAC part number | 925574 |
| Model code | HFS 2156-1W-0020-0060-7-B-1-000 |
| Measuring principle | Variable area float, external reed contact |
| Medium | Oils and viscous fluids, 30 to 600 cSt |
| Switching range | 20 to 60 L/min |
| Mechanical connection | G1, female on both ends |
| Housing material | Brass, nickel-plated |
| Switching output | 1 change-over reed contact (1W) |
| Switching capacity | Max. 250 V / 1.5 A / 50 VA (size 2, change-over contact, M12x1) |
| Electrical connection | Male M12x1, 4 pole (connector not supplied) |
| Pin assignment | 1 centre, 2 N/C, 3 not used, 4 N/O |
| Accuracy | ≤ ±10 % of full scale |
| Repeatability | 2 % of full scale max. |
| Fluid temperature | -20 to +85 °C (M12x1 version) |
| Pressure drop | 0.02 to 0.4 bar |
| Protection class | IP 65 |
| Approvals as printed | CE mark |
| Weight | 2.75 lb |
How this code differs from the smaller switch
HFS 2156-1W-0020-0060-7-B-1-000: the third digit 5 selects the 1 inch connection and the fourth digit 6 the M12x1 four-pole plug. 1W means one change-over contact, 0020-0060 the 20 to 60 L/min range, 7 the 10 % accuracy class, B the brass body, 1 the mechanical indicator and 000 the standard modification. The M12 version has a lower fluid temperature limit (85 °C) than the DIN plug version (120 °C), and the size 2 change-over contact is rated max. 250 V / 1.5 A / 50 VA, so check the load of your input card against that rating.
Installation notes
The oil must be free of solid particles and a contamination strainer is recommended. The switch works in any mounting position but strong external magnetic fields, such as those from motors, can disturb the contact, so keep it clear of them. Its contact opens or switches when the flow drops below the preset switching point. Use the pin table in the datasheet, which lists the centre pin, N/C on pin 2 and N/O on pin 4, when wiring a PLC input.
Place the switch on a vertical or horizontal run with enough straight pipe before it to settle the flow, and take the viscosity of your oil into account when you choose the switching point. The datasheet states a calibration to a particular viscosity can bring the accuracy to 3 percent, so mention your oil grade in the enquiry.
The datasheet also offers a stainless steel housing and an ATEX version for potentially explosive areas, so mention any hazardous-area requirement when you ask for a quotation. Choose the switching point with margin, because accuracy is within 10 percent of full scale and the switch point can shift with oil viscosity.
Documents and quotation
The HFS 2100 datasheet is attached. Please state the oil, switching point, voltage and plug type. See also our flow indicators and switches range.
How the HFS 2156-1W-0020-0060-7-B-1-000 works
Like every HFS 2100 switch, this model uses a variable-area float. A spring-loaded float with a built-in magnet is pushed along the flow path by the oil, and its position depends on the flow rate. A reed contact mounted outside the housing switches when the magnet reaches the preset position, so the electrical part never touches the oil. The switch casing can be moved steplessly to set the switching point anywhere in the 20 to 60 L/min range.
On the HFS 2156-1W-0020-0060-7-B-1-000 the change-over (1W) contact gives both an N/O and an N/C output. HYDAC states that the contact opens or switches when the flow falls below the preset switching point, and that the instrument compensates for viscosity changes between 30 and 600 cSt and works in any mounting position.
Datasheet values for HFS 2100 size 2
| Parameter | Value |
|---|---|
| Operating pressure | 250 bar (brass), 300 bar (stainless steel) |
| Pressure drop | 0.02 – 0.4 bar |
| Accuracy | ±10 % FS (3 % possible when calibrated to a certain viscosity) |
| Repeatability | 2 % FS max. |
| Operating (ambient) temperature | –20 to +70 °C |
| Fluid temperature, M12x1 plug | –20 to +85 °C |
| Parts in contact with medium (brass) | Stainless steel 1.4571, FPM, nickel-plated brass, brass, hard ferrite |
| Minimum contact load | 3 VA (change-over contact) |
| Connection (1 in) | DN 25, wrench size 40 mm, installation length 130 mm |
| Weight with indicator | Approx. 1250 g |
Selection & ordering guide
- Range: for 20–60 L/min the datasheet lists the 1 inch connection; neighbouring ranges are 15–45 and 30–90 L/min.
- Plug: 6 = M12x1 4-pole (connector not supplied); 5 = EN175301-803 (DIN 43650) with connector and a higher fluid temperature limit.
- Contacts: 1S, 2S, 1W or 2W. A second contact is fitted at 90° to the first.
- Housing: B = nickel-plated brass, S = stainless steel 1.4571 with a higher pressure rating.
- Indicator: 1 = with mechanical indicator, 0 = without.
Our team can help confirm the correct ordering code for the HFS 2156-1W-0020-0060-7-B-1-000, a matching M12 cable, or a version with a stainless steel housing or ATEX approval.
Installation & maintenance
- Fit a contamination strainer upstream; HYDAC states the medium must not contain solid particles.
- Keep a sufficient distance from magnetic fields, for example from electric motors.
- Wire the M12 plug as per the datasheet pin table and confirm the PLC input load is above the 3 VA minimum for the change-over contact or use a suitable relay.
- Set the switching point at normal operating temperature and viscosity.
- During maintenance, check the switching point and clean the strainer, since debris on the float can affect switching.
Typical applications in Oman & the GCC
The datasheet names central and circulating lubrication systems, transformers, cooling circuits, hydraulic systems, pumps, welding and laser systems and the chemical industry. In Oman and the GCC the HFS 2156-1W-0020-0060-7-B-1-000 suits lube-oil return monitoring on large gearboxes, compressors and turbines, oil cooling loops and hydraulic power units where a flow-loss trip is required.
Why source the HFS 2156-1W-0020-0060-7-B-1-000 from Seven Star LLC
Seven Star LLC supplies HYDAC flow switches across Oman and the GCC. Send the model code, oil grade, switching point and plug type to request a quote, and our team can help confirm the correct ordering code.
Datasheets & Documents
- Datasheet Hydac HFS 2100 flow switch for oils datasheet (E 18.379.1/11.13) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
Related products
Frequently Asked Questions
20 to 60 L/min.
One change-over reed contact, with N/C on pin 2 and N/O on pin 4 of the M12 plug.
A male M12x1 four-pole plug; the mating connector is not supplied.
G1 female on both ends, as listed in the catalogue item.
85 °C for the M12x1 version (185 °F).