Brand: Cortem
Cortem NEVCF Ex Cable Glands for Armoured Cold-Flow Cable
Description
Ex d/e cable glands for armoured cables that suffer cold flow
The Cortem NEVCF series are cable glands for circular armoured cables only, entering Ex db enclosures with threaded entries and Ex eb or Ex tb enclosures with threaded or flat entries. The datasheet explains that the series is designed to prevent cold flow: the tendency of a solid material to deform under constant mechanical pressure, so that the sheath under the armour deforms over time and undermines both the cable and the gland seal. Unlike traditional glands, NEVCF uses a rubber seal that closes on the cable sheath, in line with IEC/EN 60079-14, which makes it suitable for cold-flow cables.
Protection is IP66/67/68. With cylindrical threads the gland is used with a flat gasket; for other threads the IP rating relies on sealant applied over at least two full threads. A full accessory kit version (code NEVCF…/K) includes locknut, gasket, earthing ring, serrated stainless lock washer and a black PVC protector.
Technical specifications of the NEVCF series
| Parameter | Specification |
|---|---|
| Manufacturer | Cortem S.p.A., Italy (Elfit brand site for certificates) |
| Classification | Group II, category 2GD; Zones 1, 2, 21, 22 |
| Marking | II 2 GD Ex db IIC Gb, Ex eb IIC Gb; II 2 D Ex tb IIIC Db |
| Certificates | ATEX CESI 24 ATEX 016 X; IECEx CES 24.0012X |
| Operating temperature | -60 to +80 °C |
| Protection | IP66/67/68 |
| Cable type | Circular armoured cable, including cold-flow cable |
| Material | Nickel-plated brass |
| Thread options | 3/8 to 4 inch NPT or M16x1.5 to M100x1.5 ISO metric |
| Design standards | BS 6121 Part 1:1989, IEC 62444, EN 62444; EN 60079-0, -1, -7, -14; EN 60529 |
Selection table for common sizes
Ranges are as printed in the datasheet: Od is the internal cable sheath, OD the outer sheath of the cable, with armour wire thickness, all in millimetres.
| NPT / ISO code | Thread | Inner sheath Od (mm) | Outer sheath OD (mm) | Armour thickness (mm) |
|---|---|---|---|---|
| NEVCF01SNB / NEVCF16SIB | 3/8″ NPT / M16x1.5 | 3.5 – 8.0 | 6.5 – 12.0 | 0.8 – 1.25 |
| NEVCF01NB / NEVCF16IB | 3/8″ NPT / M16x1.5 | 6.0 – 11.0 | 9.0 – 16.0 | 0.8 – 1.25 |
| NEVCF1SNB / NEVCF20SIB | 1/2″ NPT / M20x1.5 | 6.0 – 11.0 | 9.0 – 16.0 | 0.8 – 1.25 |
| NEVCF1NB / NEVCF20IB | 1/2″ NPT / M20x1.5 | 8.5 – 14.5 | 12.0 – 20.0 | 0.8 – 1.25 |
| NEVCF2NB / NEVCF25IB | 3/4″ NPT / M25x1.5 | 12.0 – 20.0 | 16.0 – 26.0 | 1.25 – 1.6 |
| NEVCF3NB / NEVCF32IB | 1″ NPT / M32x1.5 | 17.0 – 26.0 | 20.0 – 33.0 | 1.6 – 2.0 |
| NEVCF4NB / NEVCF40IB | 1 1/4″ NPT / M40x1.5 | 23.0 – 32.0 | 29.0 – 41.0 | 1.6 – 2.0 |
| NEVCF5NB / NEVCF50IB | 1 1/2″ NPT / M50x1.5 | 29.0 – 41.0 | 36.0 – 52.0 | 1.8 – 2.5 |
The range continues to NEVCF6NB (2 inch), NEVCF7NB (2 1/2 inch), NEVCF8NB (3 inch), NEVCF9NB (3 1/2 inch) and NEVCF10NB (4 inch NPT, M100x1.5) with outer sheath up to 104 mm.
Selection and what to confirm before ordering
Choose the gland by the cable inner sheath diameter, outer sheath diameter and armour wire thickness, not by the thread alone. Confirm the thread type and size of the enclosure entry, the cable construction (circular armoured, and whether the sheath is a cold-flow material), the zone, the required ingress rating and whether the accessory kit is wanted. Armour must be clamped and earthing continuity maintained as the instructions require; an earthing ring is an accessory. The barrier alternative for armoured cable in the same manufacturer range is the NEVB series; Cortem lists the NAVB series for unarmoured cable.
Related Cortem products: Cortem NAVB Ex Barrier Cable Glands for Non-Armoured Cable, Cortem EV Ex d Luminaires for Traditional and LED Lamps, Cortem EVNL-40 Ex nR LED Floodlight for Zone 2, 21, 22, Cortem PYN-SPYN Ex Plugs and Sockets 16 A to 125 A, Cortem EJBC Aluminium Ex d Junction Boxes for Gas Group IIC and Cortem VSE Ex LED Warning Beacon, Flashing or Fixed.
Documents and quotation
The attached document is the Cortem NEVCF cold-flow cable glands datasheet (catalogue pages 22-23, edition 2026).
For a quotation, send the model code, voltage, zone and gas or dust group, cable entry details and quantity. See Electrical Tapes & Cable Accessories for related hazardous-area equipment.
Datasheets & Documents
- Datasheet Cortem NEVCF cold-flow cable glands datasheet (ED.2026) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Cortem is the Italian maker of explosion-proof and increased-safety electrical equipment: Ex d and Ex e lighting, enclosures, control stations, plugs and sockets, cable glands and signalling devices. Marco Rossi and Renato Gratton founded the company on 24 February 1968 in Villesse, in the Friuli Venezia Giulia region of north-east Italy. Cortem S.p.A. heads the Cortem Group, which also includes Elfit and the Fondisonzo foundry, and supplies onshore and offshore oil and gas, chemical and industrial plants.
Seven Star LLC is an independent supplier in Muscat. We list Cortem junction boxes, lighting, plugs and sockets and control stations for oil and gas and process projects in Oman and the GCC.
Cortem company profile
| Founded | 24 February 1968, Villesse (Gorizia), Italy |
|---|---|
| Founders | Marco Rossi and Renato Gratton |
| Name | From the Italian for electromechanical construction and technical representation |
| Group companies | Cortem S.p.A., Elfit and Fondisonzo |
| Approvals | ATEX and IECEx certified explosion-protected equipment |
| Product families | Ex d and Ex e luminaires and LED fittings, emergency and exit lights, obstruction lights, junction and control boxes, control stations, plugs and sockets, cable glands, alarm and signalling devices |
Milestones
- 1968: Marco Rossi and Renato Gratton found Cortem in Villesse on 24 February.
- 2011: Research and development on LED lighting for hazardous areas begins.
- 2012: The first Cortem LED fixture series is launched.
- 2022: The third generation of Cortem LED fixtures is released.
Cortem product series
Enclosures include the EJBX stainless steel Ex d junction boxes, EJBC aluminium Ex d boxes for gas group IIC, the SA and SAG Ex eb aluminium boxes in 18 sizes and the EJBE and EJBXE Ex de control and distribution boards. Control and power connection products include the CMD Ex e fibreglass control stations and the PYN, SPYN and CMBSP07 Ex plugs and sockets from 16 to 125 A.
Lighting covers the SLED-ME and EVL-40 Ex LED floodlights, the Ex nR SLED-MN and EVNL-40 floodlights for zone 2, the LIFEX-M linear fixture, the FLOWEX high bay, the EVML low bay, STREETEX street lighting and the XLFE-LIB and XLFE-MIA obstruction lights for stacks and towers. The GRDE-4200 is an electronic earthing system for road tanker loading bays.
Where Cortem equipment is used
Refineries, gas plants, tank farms and loading terminals, offshore platforms and ships, chemical and pharmaceutical plants and mining. Products are certified to ATEX and IECEx, with other schemes according to model.
Cortem products we list
Ordering Cortem products: what we need
Send the model code, the zone and gas or dust group, temperature class, ingress protection, the certification scheme required, and for enclosures the size, entries and internal components. For lighting give the wattage, voltage and mounting; for plugs and sockets the current, poles and voltage.
Facts checked against Cortem Group's published company history, October 2026.
Browse Cortem products by category: Automation Accessories.
FAQ
Questions about the Cortem NEVCF Ex Cable Glands for Armoured Cold-Flow
Answers from our engineering team on installation, compatibility and integration.
01What is cold flow?
The slow deformation of a cable sheath under constant pressure, which can compromise the cable and the gland seal.
02Is NEVCF for unarmoured cable?
No. It is for circular armoured cable only.
03What ingress rating applies?
IP66/67/68, with a flat gasket on cylindrical threads or sealant on at least two threads otherwise.
04Which zones is it certified for?
Zones 1, 2, 21 and 22 with Ex db IIC, Ex eb IIC and Ex tb IIIC marking.
05What is the operating temperature?
-60 to +80 °C.