Brand: Delta
Delta CP2000 Fan and Pump Vector Control Drive
Description
Overview
The Delta CP2000 is the Delta Electronics AC motor drive dedicated to fans, pumps and HVAC systems. Delta built it around variable torque loads: it includes special HVAC parameters and PID control for efficient operation, a multi-segment V/F curve, soft start, fire mode and bypass functions, and multi-pump control for up to 8 motors. With ratings from 0.75 kW at 230 V up to 630 kW at 460 V and 690 V, a single drive family can cover small exhaust fans in a commercial building and large cooling tower fans or circulation pumps in a central plant.
Seven Star LLC supplies the Delta CP2000 to MEP contractors, facility management companies, district cooling operators and water utilities across Oman and the GCC. Our engineers in Muscat check the supply voltage, duty rating and frame size against the Delta catalogue, recommend communication cards for the building management system, and support commissioning teams on projects in Muscat, Duqm and Salalah.
Operating Principle
Fans and centrifugal pumps follow the affinity laws: flow is proportional to speed, and absorbed power falls roughly with the cube of speed. Reducing speed by a modest amount therefore cuts power sharply compared with throttling a valve or damper at full speed. The Delta CP2000 exploits this by holding a process variable such as duct static pressure, differential pressure across a chilled water loop or supply water temperature at a setpoint through its PID controller, slowing the motor whenever demand allows. When demand falls far enough the sleep function stops the motor, and the drive wakes it again when the measured value drifts away from the setpoint.
Under the hood the Delta CP2000 offers V/F control with a 4-point adjustable curve, sensorless vector control (SVC) and a permanent magnet motor mode, with up to 150 percent or more starting torque at 0.5 Hz according to the general specifications. Auto energy saving adjusts the output voltage to the load at constant speed. Flying start lets the drive catch a fan that is already windmilling, and auto restart after a momentary power loss brings ventilation and pumping back without operator action.
Engineering Design of the Delta CP2000
The Delta CP2000 uses a modular construction: a hot pluggable LCD keypad, I/O extension cards, communication cards and removable fans. The keypad is a text panel that can be customised with Delta TP Editor software, and parameter groups and parameter copy speed up commissioning of many identical drives. Circuit boards carry enhanced conformal coating for durability in critical environments, and depending on the rating the drive includes a DC choke, a brake unit and an EMC filter. Delta rates operation at up to 50 degrees Celsius in light duty at 2 kHz carrier frequency, with IP20 open type or UL Type 1 / NEMA 1 enclosures depending on frame.
A built-in PLC with 10k steps and a real-time clock lets the drive handle time-based schedules and local logic, such as alternating duty pumps or running ventilation to a timetable, even when the building management system is offline. Built-in BACnet MS/TP and Modbus reduce wiring for building automation, and optional cards add BACnet IP, PROFINET, PROFIBUS DP, DeviceNet, Modbus TCP, EtherNet/IP and CANopen. Dual ratings for light duty and normal duty let engineers size the drive to the real load profile.
Key Features
Delta highlights the following Delta CP2000 functions for fan, pump and HVAC duty.
- Built-in BACnet MS/TP and RS-485 Modbus, with optional fieldbus cards including BACnet IP.
- Fire mode and bypass functions to maintain pressure and smoke extraction during emergencies.
- PID control with sleep and wake-up, flying start, skip frequency and low-current protection against running a free load.
- Synchronous control of up to 8 motors with fixed amount and fixed time circulation control.
- Built-in PLC with 10k steps and real-time clock for local scheduling.
- Light duty overload of 120 percent for 1 minute in every 5 minutes, and normal duty overload of 120 percent for 1 minute in every 5 minutes plus 160 percent for 3 seconds in every 25 seconds.
- Deceleration Energy Backup to bring the motor to a controlled stop on sudden power failure.
- Maximum output frequency of 599 Hz and enhanced conformal coating on PCBs.
Industrial Applications
Cooling dominates electrical demand in Oman and the GCC, so fan and pump drives have a direct effect on operating cost. The Delta CP2000 is suited to chilled water and condenser water pumps, cooling tower fans, air handling units, car park ventilation and stair pressurisation fans in commercial towers, hotels, hospitals and shopping malls in Muscat. Its fire mode helps engineers meet the smoke control intent of the building design, while BACnet integration lets the facility team monitor every drive from the building management system.
Outside buildings, the Delta CP2000 serves municipal water pumping stations, irrigation networks, desalination plant transfer pumps and industrial cooling water systems in the Sohar and Salalah free zones. Seven Star LLC supplies the Delta CP2000 with matching keypads and communication cards, and our Muscat team supports utilities and contractors with selection, multi-pump configuration and spare drive planning.
Technical Specifications
The table lists main Delta CP2000 data from the Delta Electronics catalogue. Model specific currents and dimensions are in the attached document.
| Parameter | Specification |
|---|---|
| Model | Delta CP2000 series (VFDxxxCP23x / CP43x / CP4Ex / CP53x / CP63x) |
| Power range, 230 V | 0.75 to 90 kW |
| Power range, 460 V | 0.75 to 630 kW |
| Power range, 575 V / 690 V | 1.5 to 15 kW / 18.5 to 630 kW |
| Control mode | V/F, SVC, PM (permanent magnet motor) |
| Starting torque | Up to 150% or above at 0.5 Hz |
| Max. output frequency | 599.00 Hz |
| Overload, light duty | 120% of rated current for 1 minute every 5 minutes |
| Overload, normal duty | 120% for 1 minute every 5 minutes; 160% for 3 seconds every 25 seconds |
| Built-in communication | RS-485 Modbus, BACnet MS/TP |
| Optional communication | BACnet IP, PROFINET, PROFIBUS DP, DeviceNet, Modbus TCP, EtherNet/IP, CANopen |
| Built-in PLC | 10k steps with real-time clock |
| Multi-pump control | Up to 8 motors |
| Enclosure | IP20 / UL open type or IP20 / UL Type 1 / NEMA 1 (by frame) |
| Operating temperature | –10 to 40 °C (UL Type 1); up to 50 °C in light duty at 2 kHz carrier |
How to Order
For a quotation on the Delta CP2000, send Seven Star LLC the model code or the motor kW, voltage and application, together with any BACnet or fieldbus requirement. Our Muscat instrumentation and automation division confirms availability, provides the Delta catalogue for submittals, and supports consultants and contractors in Oman and the GCC. Other HVAC and pump drives we supply include the Danfoss VLT AQUA Drive FC 202, the ABB ACQ580 and the Siemens SINAMICS G120X infrastructure drive.
Datasheets & Documents
- Catalog Delta CP2000 Series Fan/Pump Vector Control Drive Catalogue (English, Delta Electronics) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Delta Electronics is a Taiwanese maker of power and automation products, founded in April 1971 by Bruce Cheng with 15 employees in a small factory in Sinjhuang, Taipei County. Its first products were TV deflection coils and electronic components; it later became a leading maker of switching power supplies and added drives, PLCs and HMIs for industrial automation. Delta is headquartered in Neihu, Taipei, and listed on the Taiwan Stock Exchange.
Seven Star LLC lists the Delta DVP04AD-S2 analog input module and the ESR-48/30D rectifier module, and sources Delta PLC modules and power parts for panel builders and maintenance teams in Oman and the GCC.
Delta company profile
| Founded | April 1971, Sinjhuang, Taipei County, Taiwan |
|---|---|
| Founder | Bruce C.H. Cheng |
| First products | TV deflection coils and electronic components |
| Headquarters | Neihu District, Taipei, Taiwan |
| Listing | Taiwan Stock Exchange (2308) |
| Product families | DVP and AS series PLCs, C2000 Plus, CP2000, CH2000, MH300 and ME300 AC motor drives, REG2000 regenerative units, DIN Pro and DIN Eco DIN-rail power supplies, HMIs and servo systems |
Milestones
- 1971: Bruce Cheng founds Delta with 15 employees.
- 1975: Delta is reorganised as a company limited by shares.
- 2021: Delta marks 50 years.
Delta PLC families and the DVP slim line
Delta's controller program runs from the DVP series through the modular AS series to the AH series. Inside the DVP series, the slim CPUs (among them DVP-SS2, SA2, SX2, SV2 and SE) take slim expansion modules on their right side. The DVP04AD-S2 is one of these: a four-channel analog input module for voltage or current signals, which the CPU reads with FROM and TO instructions.
Delta products we list
Ordering Delta parts: what we need
For PLC modules, send the complete type from the side label, including the suffix, and the CPU model it will join. For a rectifier module, send the type, the DC output voltage and current, the AC input, and the model of the power shelf or system it plugs into.
Facts checked against Delta's own 50th anniversary timeline (delta50.deltaww.com), October 2026.
Browse Delta products by category: PLC & I/O Cards, Power Modules.
FAQ
Questions about the Delta CP2000 Fan and Pump Vector Control Drive
Answers from our engineering team on installation, compatibility and integration.
01What is the Delta CP2000 designed for?
Delta designed the CP2000 for energy-saving HVAC systems and for pump and fan applications. It carries dedicated HVAC parameters, PID control with sleep and wake-up, flying start, skip frequency and a 4-point adjustable V/F curve for variable torque loads.
02Does the Delta CP2000 support BACnet?
Yes. BACnet MS/TP and Modbus over RS-485 are built in. Optional cards add BACnet IP, PROFINET, PROFIBUS DP, DeviceNet, Modbus TCP, EtherNet/IP and CANopen, so the drive can report to a building management system or a plant PLC.
03What is fire mode on the Delta CP2000?
Fire mode and bypass functions keep the fan running to maintain pressure and extract smoke when an emergency occurs, rather than tripping on protective faults. The exact behaviour is configured by parameters and must be engineered with the life safety design of the building.
04How many pumps can one Delta CP2000 coordinate?
Delta states that the CP2000 provides synchronous control of up to 8 motors at one time, with fixed amount and fixed time circulation control. This allows duty and standby pumps to share running hours on chilled water and condenser water systems.
05Does Seven Star LLC supply the Delta CP2000 in Oman?
Yes. Seven Star LLC supplies the Delta CP2000 and its communication cards and keypads to HVAC contractors, district cooling operators and water utilities in Oman and the GCC. Our Muscat engineers check voltage, duty rating and frame against the Delta catalogue before order.