Brand:

Beamex MC6-T Multifunction Temperature Calibrator and Communicator

Description

Overview

The Beamex MC6-T is a multifunction temperature calibrator and communicator that combines a temperature dry block with a built-in process calibrator based on Beamex MC6 technology. It generates temperature, measures and simulates temperature and electrical signals, measures pressure with Beamex modules, and communicates with HART, FOUNDATION Fieldbus H1 and Profibus PA instruments, all in one portable device. Beamex offers two models: the Beamex MC6-T150, which generates temperatures from −30 to 150 °C, and the MC6-T660, which covers 50 to 660 °C. Beamex describes it as the most versatile temperature calibrator, able to replace a dry block, temperature calibrator, electrical calibrator, pressure calibrator, field communicator and loop supply.

Seven Star LLC supplies the MC6-T, inserts, reference sensors and accessories to instrument and maintenance departments, calibration laboratories and service contractors in Muscat, the Sultanate of Oman and the GCC. We provide engineering support in Muscat for choosing the right model, insert drillings and communicator options.

Operating Principle

The temperature block of the Beamex MC6-T heats or cools a metal insert to a set point while the internal or an external reference sensor measures the actual temperature. Sensors under test are placed in borings of the insert and compared against the reference. The MC6-T660 uses active triple zone temperature control and the MC6-T150 uses dual zone heating and cooling; the multi-zone control compensates for heat lost through the installed sensors and gives an excellent axial gradient. Beamex states that its control algorithm provides fast heating and cooling without overshoot, and the control speed can be adjusted to balance speed against accuracy.

Because temperature changes slowly, the calibrator includes a stability control function. It tracks the stability and two-sigma standard deviation of readings for both the reference sensor and the sensors being calibrated, and only accepts values that meet the stability criterion, so even a less experienced user achieves the best uncertainty. At the same time the built-in process calibrator can read up to three RTD or resistance channels and two thermocouple channels, simulate RTDs and thermocouples, and measure or generate mA and voltage. This allows a complete temperature loop, from sensor through transmitter to the 4 to 20 mA output, to be calibrated with one instrument.

Engineering Design of the Beamex MC6-T

The Beamex MC6-T measures 322 x 180 x 298 mm and weighs 9.4 kg (MC6-T150) or 8.6 kg (MC6-T660), with a 5.7-inch 640 x 480 colour touch screen usable with bare fingers, gloves or a stylus, plus a membrane keyboard. Six user modes are provided: Temperature Calibrator, Calibrator, Documenting Calibrator, Data Logger for up to nine simultaneous measurements, Communicator and Settings. Power is 230 or 115 V AC, with 380 W for the MC6-T150 and 1560 W for the MC6-T660, and an internal 4300 mAh lithium-ion battery runs all functions except temperature generation and R3 measurement for 10 to 16 hours. Interfaces are USB and Bluetooth.

Both models have a 150 mm immersion depth, with insert outer diameters of 30 mm (MC6-T150) and 24.5 mm (MC6-T660). Safety features include a red hot-block indicator, a tilt sensor on the MC6-T660 that warns the user and switches off heating if the unit tilts or falls, and processor-independent overheat protection. The MC6-T150 supports calibration of short and flanged sanitary sensors using a dedicated insert, a very short reference probe and cable grooves in the cover. The unit can also control external temperature blocks such as the Beamex FB and pressure controllers such as the Beamex ePG or POC8, and connects to Beamex external pressure modules. An accredited calibration certificate is included, and the warranty is three years (one year for the battery).

Key Features

Key features of the Beamex MC6-T from the Beamex brochure are:

  • Temperature dry block and MC6-based process calibrator in one portable unit.
  • MC6-T150 for −30 to 150 °C and MC6-T660 for 50 to 660 °C.
  • Display uncertainty with internal reference of ±0.15 °C (MC6-T150) and ±0.2 to ±0.5 °C (MC6-T660).
  • Three simultaneous RTD and two thermocouple measurement channels, plus RTD and TC simulation.
  • Built-in HART, FOUNDATION Fieldbus H1 and Profibus PA communicator with 24 V loop supply.
  • Documenting calibrator working with Beamex CMX and LOGiCAL software, with Bluetooth data transfer.
  • Stability control based on two-sigma deviation of readings.
  • Rechargeable battery for all functions except temperature generation.

Industrial Applications

The Beamex MC6-T is used to calibrate RTD and thermocouple sensors, temperature transmitters, temperature switches and complete temperature loops in process plants. Because it also measures mA, voltage, frequency and pressure, the same instrument can handle pressure transmitters and other loop devices during a maintenance round. The MC6-T150 range fits HVAC, food, beverage and pharmaceutical applications including sanitary sensors, while the MC6-T660 serves high temperature process measurements on heaters, reactors, furnaces and steam systems. With calibration management software, the Beamex MC6-T downloads work orders, guides the technician and returns results digitally.

In Oman and the GCC, the Beamex MC6-T is relevant to refineries and petrochemical plants in Sohar, gas processing and LNG facilities, power and desalination stations, food and beverage producers and pharmaceutical manufacturers, as well as calibration service companies. Its built-in communicator is valuable on sites standardising on HART and fieldbus instruments, and the operating range of 0 to 45 °C should be considered for outdoor work in summer. Seven Star LLC supplies the Beamex MC6-T with the required inserts and options and can combine it with existing Beamex MC6 field equipment.

Technical Specifications

The Beamex MC6-T specifications below are taken from the Beamex MC6-T brochure.

Parameter Specification
Model Beamex MC6-T150 and MC6-T660
Temperature range MC6-T150: −30 to 150 °C; MC6-T660: 50 to 660 °C
Display uncertainty (internal reference) MC6-T150: ±0.15 °C; MC6-T660: ±0.2 °C at 50 °C, ±0.3 °C at 420 °C, ±0.5 °C at 660 °C
Stability (30 min, 2 sigma) MC6-T150: ±0.01 °C; MC6-T660: ±0.02 to ±0.04 °C
Axial uniformity at 40 mm MC6-T150: ±0.05 °C; MC6-T660: ±0.05 to ±0.40 °C
Immersion depth / insert diameter 150 mm; 30 mm (T150), 24.5 mm (T660)
Heating time T150: 23 to 150 °C in 19 min; T660: 50 to 660 °C in 15 min
Electrical functions RTD (3 ch), TC (2 ch), resistance 0 to 4 kohm, ±100 mA, −1 to 60 V DC, frequency 0 to 50 kHz, pulses
Generation 0 to 55 mA, −3 to 24 V DC, frequency and pulse queue; 24 V DC loop supply
Communicator HART, FOUNDATION Fieldbus H1, Profibus PA (optional protocols)
Display 5.7-inch 640 x 480 TFT, 5-wire resistive touch screen
Power 230 or 115 V AC; 380 W (T150), 1560 W (T660)
Battery Li-ion 4300 mAh, 11.1 V; 10 to 16 h
Interfaces USB, Bluetooth
Dimensions / weight 322 x 180 x 298 mm; 9.4 kg (T150), 8.6 kg (T660)

How to Order

For a quotation on the Beamex MC6-T, tell Seven Star LLC which model you need, the sensor diameters to be calibrated for insert selection, the communicator protocols required and any pressure modules or software. The Beamex MC6-T brochure is available as a download on this page. Seven Star LLC supplies Beamex calibrators in Oman and the GCC with engineering support in Muscat. Related products include the Beamex MC6 Advanced Field Calibrator and Communicator, the Beamex MB Metrology Temperature Block and the Beamex MC6-Ex Intrinsically Safe Field Calibrator.

Datasheets & Documents
  • PDF Brochure Beamex MC6-T Multifunction Temperature Calibrator Brochure (manufacturer) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.

Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.

Beamex company profile

Origin Founded in 1975 in Finland by four calibration technicians; first factory 1977
Headquarters Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992
Product families MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software
Typical duty Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters

Milestones

  • 1975: Four calibration technicians found the company in Finland.
  • 1977: The first factory opens.
  • 1992: ISO 9001 certification.

Beamex calibrators and accessories

Model Type Typical use
MC6 Advanced field calibrator and communicator Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results
MC6-Ex Intrinsically safe field calibrator Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit
MC6-T Temperature calibrator with integrated dry block Temperature sensors and transmitters, with multifunction electrical and pressure measurement
MC4, MC2 Documenting and hand-held process calibrators Routine loop, transmitter and switch checks in the field
FB, MB Field and metrology temperature dry blocks FB for field calibration; MB for higher-accuracy workshop and laboratory work
ePG, POC8 Electric pressure pump and automatic pressure controller Automated pressure calibration; POC8 for workshop calibration benches
PGC, PGM, PGL, PGPH, PGHH Hand pressure pumps Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH)
EXT modules External pressure modules Extending MC calibrators to additional ranges, 70 kPa to 100 MPa

Where Beamex equipment is used

Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.

Ordering Beamex equipment: what we need

State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.

Facts checked against Beamex company history and product information, October 2026.

FAQ

Questions about the Beamex MC6-T Multifunction Temperature Calibrator

Answers from our engineering team on installation, compatibility and integration.

01What temperature ranges does the Beamex MC6-T cover?
The MC6-T150 generates temperatures from -30 to 150 C and the MC6-T660 covers 50 to 660 C, both with a 150 mm immersion depth.
02Can the Beamex MC6-T calibrate temperature transmitters as well as sensors?
Yes. The built-in process calibrator can measure and simulate RTD and thermocouple signals and measure mA, so complete temperature loops and transmitters can be calibrated with the same unit.
03Does the Beamex MC6-T include a HART communicator?
Yes. It includes a field communicator for HART, FOUNDATION Fieldbus H1 and Profibus PA, with a built-in loop supply and impedances. Protocols are modular and can be added later.
04Can the Beamex MC6-T run on battery?
The internal rechargeable battery runs all functions except temperature generation and R3 measurement for 10 to 16 hours, so the process calibrator and communicator can be used without mains power.
05Does Seven Star LLC supply the Beamex MC6-T in Oman?
Yes. Seven Star LLC supplies the Beamex MC6-T150 and MC6-T660 with inserts, reference sensors and accessories in Muscat, throughout Oman and the GCC.