Beamex 9010920 CS40 calibration stand overview
The Beamex CS40 calibration stand, order code 9010920, helps technicians calibrate pressure transmitters, pressure indicators and both analog and digital pressure gauges in workshop and laboratory environments. It provides a stable base and includes the pressure connections needed for the pressure source and the reference pressure module.
The stand also works as a manifold with three G1/8 inch female pressure ports: one fitted with a Bx G1/8 male fitting for the Beamex 40 bar hose and two plugged. Maximum pressure is 40 bar (580 psi).
This page describes Beamex 9010920 for buyers who need the exact order code. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Key features of the CS40 calibration stand
- Stable base for pressure transmitters, indicators and gauges
- Manifold with three G1/8 female ports, one with Bx G1/8 male fitting for 40 bar hose, two plugged
- Hand-tightened quick-connect G1/2 female port holds the device under test vertically
- Maximum pressure 40 bar (580 psi)
- O-ring set 6.3 x 2.4 mm (10 pcs) included for sealing the device under test
Standard delivery and contents according to Beamex:
- Calibration stand with hand-tightened quick-connect G1/2 female pressure port
- O-ring set 6.3 x 2.4 mm (10 pcs)
Technical specifications of Beamex 9010920
| Order code | 9010920 |
|---|---|
| Maximum pressure | 40 bar / 580 psi |
| Manifold ports | 3 x G1/8 female (one with Bx G1/8 male fitting, two plugged) |
| DUT port | G1/2 female, hand-tightened quick-connect |
| Included | O-ring set 6.3 x 2.4 mm (10 pcs) |
| Module adapter (optional) | 6044423 pressure fitting G1/2 B male to G1/8 female for EXT modules 100m to 20C |
All values are taken from Beamex documentation. Items not shown here are not stated in the manufacturer source and are therefore left out.
Typical applications in Oman and the GCC
Workshop calibration of pressure transmitters, indicators and gauges is easier when the device under test is held securely. In instrument shops serving oil and gas, power, water and manufacturing sites across Oman and the GCC, a calibration stand turns a hand pump and a reference module into a tidy bench setup.
The CS40 calibration stand (9010920) is aimed at laboratory and workshop use where the same types of instruments are calibrated repeatedly and a stable base and manifold save time on every job.
Selection and compatibility notes for 9010920
Select the stand by maximum pressure and by the fittings used on your pump and hoses. 9010920 must only be used within its rated pressure, and the hose and pump connected to it must be rated for the same pressure or higher.
Check that the reference module and the device under test thread types match the ports of the stand, and order adapters where they do not. Beamex lists many pressure fittings separately.
Installation and commissioning
Fix or place the stand on a firm bench, fit the device under test in the quick-connect port, and connect the pressure source and reference module to the manifold ports. Make sure all unused ports are plugged and all seals are in place before pressurizing.
Increase pressure gradually, check for leaks at each connection, and release pressure fully before removing the device under test. The Beamex documentation for 9010920 gives further guidance.
Maintenance and care
Keep the ports and O-rings clean and replace worn seals promptly, since a small leak affects calibration stability. Inspect the quick-connect port regularly and wipe the stand after use.
Keep spare O-rings in the workshop so that the stand is never out of service because of a worn seal.
Related products and ordering notes
Beamex lists these related items, each with its own order code:
- 6044423 pressure fitting G1/2 B male to G1/8 female
- 9010000 PGM calibration pump
- 8009560 40 bar pressure hose 0.75 m
- 9010900 DMT40 dirt and moisture trap
Beamex is a Finnish maker of calibration equipment, and its manuals and product pages are the reference for every figure on this page. Always check the manufacturer’s current documentation before putting any accessory or spare part into service.
Seven Star LLC works with industrial maintenance, procurement and calibration teams, so requests that include the full order code, the quantity and the delivery location can be answered quickly. Order codes are often the only reliable way to separate similar-looking accessories from different product generations.
Plants in the region usually plan calibration work around shutdowns, turnarounds and seasonal maintenance windows. Ordering accessories and spare parts well before the work starts avoids waiting for a missing seal, hose or cable when the plant is already offline, and it is cheaper than expediting a single item at the last minute.
Good calibration practice also depends on traceability. Records of the reference equipment, its certificate, the environmental conditions and the as-found and as-left results are what auditors and clients ask for. Accessories do not replace the calibration of the reference itself, but a worn hose, a leaking seal or a damaged cable can spoil an otherwise good measurement, which is why consumables should be replaced on a schedule rather than only after a failure.
When you compare quotations, make sure the order code is identical. Calibration accessories from the same manufacturer often differ only by thread, length or pressure rating, and a similar-looking item with a different code may not be compatible with your equipment. Keep the code on the purchase order, the goods receipt note and the maintenance record so that the same item can be reordered later.
Frequently asked questions about 9010920
What is the maximum pressure of the CS40 9010920? The CS40 is rated to a maximum pressure of 40 bar (580 psi), according to Beamex.
What does the CS40 connect to? It has three G1/8 female manifold ports, one fitted with a Bx G1/8 male fitting for the Beamex 40 bar hose, and a G1/2 female quick-connect port for the device under test.
What devices can be calibrated on the stand? Beamex names pressure transmitters, pressure indicators and both analog and digital pressure gauges.
Is a pressure module adapter included? No. Fitting 6044423 (G1/2 B male to G1/8 female) is a separate item for Beamex external modules 100m to 20C with Bx G1/8 male thread.
What is the 210 bar version? Beamex lists the CS210 stand, order code 9010930, for pressures up to 210 bar with Bx 1215 fittings.
Documents and quotation
The official Beamex PG calibration pumps brochure is attached to this page as a PDF. It covers the Beamex PG pumps and the optional hoses and fittings (pages 4–7) that are used with a calibration stand such as the CS40. Quote order code 9010920 in your request and we will confirm compatibility with your unit in a written quotation.
Quote Beamex 9010920 exactly as written when you contact us, so that the correct item is quoted the first time. Delivery to Oman and to other GCC countries is arranged for each order, and any questions about packaging, documentation or alternative items can be raised in the same message.
Datasheets & Documents
- Datasheet Beamex PG Calibration Pumps Brochure (official PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex 9010920 CS40 Calibration Stand 40 bar
Answers from our engineering team on installation, compatibility and integration.
01What is the maximum pressure of the CS40 9010920?
The CS40 is rated to a maximum pressure of 40 bar (580 psi), according to Beamex.
02What does the CS40 connect to?
It has three G1/8 female manifold ports, one fitted with a Bx G1/8 male fitting for the Beamex 40 bar hose, and a G1/2 female quick-connect port for the device under test.
03What devices can be calibrated on the stand?
Beamex names pressure transmitters, pressure indicators and both analog and digital pressure gauges.
04Is a pressure module adapter included?
No. Fitting 6044423 (G1/2 B male to G1/8 female) is a separate item for Beamex external modules 100m to 20C with Bx G1/8 male thread.
05What is the 210 bar version?
Beamex lists the CS210 stand, order code 9010930, for pressures up to 210 bar with Bx 1215 fittings.


















Reviews
There are no reviews yet.