Brand:

Beamex 8129750 Insert Removal Tool for MC6-T, FB and MB

Description

Overview of Beamex insert removal tool for MC6-T Beamex 8129750

The Beamex 8129750 is a tool for removing the insert from the calibrator block of the MC6-T, FB or MB. The manufacturer states that the insert removal tool must always be used when taking out the insert.

Inserts can be hot after temperature work, so a dedicated tool is the safe way to change them.

This page describes Beamex insert removal tool for MC6-T for buyers who need the exact part number Beamex 8129750. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; the data below is taken from the manufacturer published product pages and brochures.

Key features of 8129750

  • Order code: 8129750.
  • Description: Insert removal tool.
  • Fits: MC6-T, FB and MB calibrator blocks.

Technical specifications for 8129750

Order code 8129750
Description Insert removal tool
Fits MC6-T, FB and MB calibrator blocks

All values above come from the manufacturer documentation and may change with later revisions. Please quote 8129750 when you need the matching datasheet or a confirmation of the current revision.

Typical applications in Oman and the GCC

Temperature dry blocks are used in instrument shops and in the field to calibrate RTDs, thermocouples and transmitters. Changing inserts is a routine job whenever probe diameters differ, and a proper tool makes it faster and safer.

Oil and gas, power and process plants in the GCC use different probe sizes, so having the removal tool next to the block is practical.

The part is relevant wherever the related calibration equipment is used: oil and gas, utilities, water, process manufacturing and calibration service providers in Oman and the wider GCC.

Equipment used in Oman and the wider GCC faces high ambient temperatures, dust and coastal humidity. Keep instruments and accessories out of direct sun, avoid leaving them in closed vehicles, and allow cold equipment to acclimatise before use when moving from an air-conditioned room to an outdoor unit. Cap connectors and threads when they are not in use so that sand and moisture stay out.

Selection and compatibility notes for 8129750

Use the tool with the MC6-T150 (9430020) and MC6-T660 (9430010), and with FB and MB dry blocks. Inserts are chosen to match the sensors being calibrated and are ordered separately.

Before ordering 8129750, confirm the model and, where relevant, the serial number or option code of the instrument it will serve. Confirm voltage, plug type, thread type or pressure rating as applicable, and check the manufacturer documentation for the firmware or hardware revision of the equipment.

If an item looks similar but carries a different part number, do not assume interchangeability. A short note of the calibrator model and application lets us confirm the match for 8129750 before it is supplied.

Installation and commissioning of 8129750

Allow the block and insert to reach a safe handling temperature. Use 8129750 to engage the insert and lift it straight out without twisting, and place the insert on a heat-resistant surface.

Refit the insert, making sure it sits fully, before starting a new temperature run.

Maintenance and care

Keep the tool clean and free from oil. Check it for bending or wear and replace it if the hook no longer engages securely.

Store 8129750 with the block accessories.

Calibration is only as useful as its records. Keep a log of serial numbers, certificate dates, replacement parts and any faults, and store the manufacturer documents with the equipment. This makes audits easier, helps predict when spares will be needed, and shortens the time needed to prepare a purchase request when a part has to be replaced at short notice.

Related products and ordering notes for 8129750

Related items are the dry block itself, matching inserts, the transport case, spare fuses and reference sensors.

Hard-to-find and discontinued spare parts are a daily topic for maintenance planners in oil, gas, power and water facilities. When a plant standardises on one calibrator family, a small stock of the exact spares is far cheaper than a day of lost production, and an early enquiry gives the supplier time to confirm availability and shipping options to Oman and neighbouring countries.

Please note that Seven Star LLC prepares each quotation for 8129750 against the exact part number, so a request that quotes the number and the quantity is answered faster than a general description.

The part number 8129750 should be quoted exactly as printed in this page, because accessories and spares with similar descriptions often differ by one digit.

When ordering 8129750 for a fleet of calibrators, mention the calibrator models in use so that compatibility can be checked before the quotation is issued.

Frequently asked questions about 8129750

  • What is 8129750 used for? To remove the insert from the block of an MC6-T, FB or MB.
  • Is it required? The manufacturer says to always use the insert removal tool for removing the insert.
  • Which models does it fit? MC6-T, FB and MB, according to the manufacturer documentation for 8129750.
  • Does it include inserts? No. Inserts are ordered separately, according to the manufacturer documentation for 8129750.
  • Should the block be hot? Let the block return to a safe temperature before handling, following the user manual.

Documents and quotation

The official Beamex MC6-T brochure is attached to this page as a PDF. The accessories list on page 19 includes the insert removal tool used to lift inserts out of the MC6-T dry block. Share order code 8129750 together with your calibrator model and we will confirm the exact part in a written quotation. Removing inserts with the proper tool rather than with pliers or improvised hooks protects both the insert and the dry block well, and allows a hot insert to be changed safely between calibration points.

Datasheets & Documents
  • PDF Datasheet Beamex MC6-T Brochure (official PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.

Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.

Beamex company profile

Origin Founded in 1975 in Finland by four calibration technicians; first factory 1977
Headquarters Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992
Product families MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software
Typical duty Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters

Milestones

  • 1975: Four calibration technicians found the company in Finland.
  • 1977: The first factory opens.
  • 1992: ISO 9001 certification.

Beamex calibrators and accessories

Model Type Typical use
MC6 Advanced field calibrator and communicator Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results
MC6-Ex Intrinsically safe field calibrator Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit
MC6-T Temperature calibrator with integrated dry block Temperature sensors and transmitters, with multifunction electrical and pressure measurement
MC4, MC2 Documenting and hand-held process calibrators Routine loop, transmitter and switch checks in the field
FB, MB Field and metrology temperature dry blocks FB for field calibration; MB for higher-accuracy workshop and laboratory work
ePG, POC8 Electric pressure pump and automatic pressure controller Automated pressure calibration; POC8 for workshop calibration benches
PGC, PGM, PGL, PGPH, PGHH Hand pressure pumps Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH)
EXT modules External pressure modules Extending MC calibrators to additional ranges, 70 kPa to 100 MPa

Where Beamex equipment is used

Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.

Ordering Beamex equipment: what we need

State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.

Facts checked against Beamex company history and product information, October 2026.

FAQ

Questions about the Beamex 8129750 Insert Removal Tool for MC6-T, FB

Answers from our engineering team on installation, compatibility and integration.

01What is 8129750 used for?
To remove the insert from the block of an MC6-T, FB or MB.
02Is it required?
The manufacturer says to always use the insert removal tool for removing the insert.
03Which models does it fit?
MC6-T, FB and MB, according to the manufacturer documentation for 8129750.
04Does it include inserts?
No. Inserts are ordered separately, according to the manufacturer documentation for 8129750.
05Should the block be hot?
Let the block return to a safe temperature before handling, following the user manual.