- Automation & ControlView all 2,798 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Beamex
Beamex 9010290 PGHS Hydraulic Calibration Pump 1000 bar
Description
Beamex 9010290 PGHS hydraulic pump overview
The Beamex PGHS, order code 9010290, is a hand-operated hydraulic high-pressure calibration pump for generating reference pressure from 0 to 1000 bar (0 to 14,500 psi) in workshops and laboratories. An adjustable three-arm handle is used to build up and fine-tune the pressure.
It runs on low-viscosity mineral-based hydraulic oil (RENOLIN MR 5 VG 22) or distilled water. Two hand-tightened quick-connect G1/2 inch female ports allow the reference module and the device under test to be fitted directly, so no hoses are needed between them and the pump.
This page describes Beamex 9010290 for buyers who need the exact order code. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Key features of the PGHS hydraulic pump
- 0 to 1000 bar (0 to 100 MPa, 0 to 14,500 psi) hydraulic pressure generation
- Three-arm handle for pressure build-up and fine adjustment
- Two hand-tightened quick-connect G1/2 inch female pressure ports
- Reference module and device under test attach directly to the ports, hoses are not required
- 200 ml reservoir for oil or distilled water
- Fitting for the Beamex EXT1000 module included in the delivery
Standard delivery and contents according to Beamex:
- PGHS pump
- Pressure fitting G1/2 male to G1/4 B female 6044422 for the EXT1000 external pressure module
- 10 pcs copper washers for G1/4 B fittings 8072700
- Pressure plug G1/2 male 6044425
- Hydraulic reservoir filling and draining tool 8003201
- User manual
Technical specifications of Beamex 9010290
| Order code | 9010290 |
|---|---|
| Pressure range | 0 to 1000 bar / 0 to 100 MPa / 0 to 14,500 psi |
| Pressure connections | 2 x hand-tightened quick-connect G1/2 inch female |
| Pressure medium | Low-viscosity mineral-based hydraulic oil (RENOLIN MR 5 VG 22) or distilled water |
| Reservoir | 200 ml / 12.2 cubic in |
| Weight | 10.5 kg / 23.15 lb |
| Height | 167 mm without handle, 337 mm with three-arm handle |
| Width | 322 mm / 12.68 in |
| Depth | 388 mm without handle, 490 mm with three-arm handle |
| Distance between ports | 181 mm / 6.86 in |
| Wetted parts | Stainless steel, aluminum, Viton, NBR |
| Operating temperature | 0 to 50 C / 32 to 122 F |
| Storage | -10 to 50 C / 14 to 122 F, 35 to 85 percent RH |
| Required handle torque | 2.0 Nm at 250 bar, 4.0 Nm at 500 bar, 8.0 Nm at 1000 bar |
All values are taken from Beamex documentation. Items not shown here are not stated in the manufacturer source and are therefore left out.
Typical applications in Oman and the GCC
Pressure calibration is a routine task wherever transmitters, gauges and switches protect a process. In oil and gas facilities, gas treatment plants, power and desalination stations, water networks and manufacturing sites around Oman and the GCC, instrument teams use a calibration pump to create a known pressure so that the reading of the device under test can be compared with a reference.
The PGHS hydraulic pump (9010290) suits instrument workshops, plant maintenance crews and metrology laboratories that need a dependable pressure source next to a reference module or documenting calibrator. Because heat and dust are common in the region, a pump that is simple to operate and easy to service helps keep calibration intervals on schedule.
Selection and compatibility notes for 9010290
Start with the pressure range and the medium. Match the maximum output of 9010290 to the highest range of the instruments you calibrate, and confirm that the medium used by the pump is acceptable for the device under test. Never connect a reference module or instrument with a lower rating than the pressure the pump can reach.
Check the thread types on both sides before ordering. Beamex publishes a fittings guide and lists many adapters and hoses separately, so a pump usually needs a matching fitting for each device under test. When the instruments in your plant use mixed BSP and NPT threads, plan an adapter set at the same time as the pump.
Installation and commissioning
Place the pump on a stable surface or hold it as the manual describes, then connect the reference and the device under test with suitable fittings and hoses. Check that seals are present and clean before tightening, and use only fittings rated for the full pressure of the application.
Raise the pressure slowly, watch the reference reading, and use the fine adjustment to settle on each test point. Release pressure through the vent or release control before disconnecting anything. Follow the safety notes in the Beamex manual for 9010290.
Maintenance and care
Keep ports and fittings clean and store the pump in its case when it is not in use. Dirt, moisture and unsuitable fluids are the most frequent causes of seal wear in any calibration pump, so protect the pump from contamination coming from the device under test.
Seals and O-rings are consumables. Beamex catalogues service and spare parts sets for its pumps, so a small spare stock lets a workshop repair a pump quickly and keep calibration work moving.
Related products and ordering notes
Beamex lists these related items, each with its own order code:
- 8003160 PGHS service kit
- 0809150 1000 bar pressure hose set with G fittings
- 8072700 copper washers for G1/4 B fittings
- 8003201 hydraulic reservoir filling and draining tool
Beamex is a Finnish maker of calibration equipment, and its manuals and product pages are the reference for every figure on this page. Always check the manufacturer’s current documentation before putting any accessory or spare part into service.
Seven Star LLC works with industrial maintenance, procurement and calibration teams, so requests that include the full order code, the quantity and the delivery location can be answered quickly. Order codes are often the only reliable way to separate similar-looking accessories from different product generations.
Plants in the region usually plan calibration work around shutdowns, turnarounds and seasonal maintenance windows. Ordering accessories and spare parts well before the work starts avoids waiting for a missing seal, hose or cable when the plant is already offline, and it is cheaper than expediting a single item at the last minute.
Good calibration practice also depends on traceability. Records of the reference equipment, its certificate, the environmental conditions and the as-found and as-left results are what auditors and clients ask for. Accessories do not replace the calibration of the reference itself, but a worn hose, a leaking seal or a damaged cable can spoil an otherwise good measurement, which is why consumables should be replaced on a schedule rather than only after a failure.
When you compare quotations, make sure the order code is identical. Calibration accessories from the same manufacturer often differ only by thread, length or pressure rating, and a similar-looking item with a different code may not be compatible with your equipment. Keep the code on the purchase order, the goods receipt note and the maintenance record so that the same item can be reordered later.
Frequently asked questions about 9010290
What pressure range does the PGHS 9010290 cover? The PGHS generates 0 to 1000 bar (0 to 100 MPa, 0 to 14,500 psi) using hand-operated hydraulics, according to the Beamex user manual.
Which fluids can be used in the PGHS? Beamex specifies low-viscosity mineral-based hydraulic oil (RENOLIN MR 5 VG 22) or distilled water. Other fluids such as synthetic hydraulic oil can damage the seals.
Do I need hoses to connect the reference module? No. The two G1/2 inch quick-connect ports take the module and the device under test directly, and a G1/4 B adapter for the EXT1000 module is included.
How heavy is the pump? The PGHS weighs 10.5 kg (23.15 lb) and has a 200 ml reservoir, so it is intended for workshop or laboratory use.
Which service kit fits the PGHS? Beamex lists the PGHS service kit 8003160, which contains O-rings and dirt collectors for the pressure ports and the priming pump piston.
Documents and quotation
The official Beamex PGHS hydraulic pump user manual is attached to this page as a PDF. It covers the set-up, priming, operation and maintenance of the PGHS hydraulic calibration pump. Send us the order code 9010290 and the serial number of your instrument and we will confirm fit and lead time in a written quotation.
Quote Beamex 9010290 exactly as written when you contact us, so that the correct item is quoted the first time. Delivery to Oman and to other GCC countries is arranged for each order, and any questions about packaging, documentation or alternative items can be raised in the same message.
Datasheets & Documents
- Datasheet Beamex PGHS User Manual (official PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex 9010290 PGHS Hydraulic Calibration Pump 1000
Answers from our engineering team on installation, compatibility and integration.
01What pressure range does the PGHS 9010290 cover?
The PGHS generates 0 to 1000 bar (0 to 100 MPa, 0 to 14,500 psi) using hand-operated hydraulics, according to the Beamex user manual.
02Which fluids can be used in the PGHS?
Beamex specifies low-viscosity mineral-based hydraulic oil (RENOLIN MR 5 VG 22) or distilled water. Other fluids such as synthetic hydraulic oil can damage the seals.
03Do I need hoses to connect the reference module?
No. The two G1/2 inch quick-connect ports take the module and the device under test directly, and a G1/4 B adapter for the EXT1000 module is included.
04How heavy is the pump?
The PGHS weighs 10.5 kg (23.15 lb) and has a 200 ml reservoir, so it is intended for workshop or laboratory use.
05Which service kit fits the PGHS?
Beamex lists the PGHS service kit 8003160, which contains O-rings and dirt collectors for the pressure ports and the priming pump piston.


















Reviews