AII GPR-1500 Trace ppm Oxygen Transmitter

Description

Overview

The AII GPR-1500 is a single-channel, loop-powered trace oxygen transmitter from Analytical Industries Inc. (AII), the Pomona, California manufacturer of electrochemical oxygen sensors and gas analyzers that now operates as a DwyerOmega brand. Designed for precise parts-per-million oxygen analysis in clean industrial gases, the AII GPR-1500 covers full-scale ranges from 0–10 ppmV up to 0–1 % O2, with a lower detection limit of 0.05 ppmV and a displayed resolution of 0.01 ppmV. It belongs to the GPR-x500 family, which shares one operator interface with the percent-level GPR-2500 and with the portable analyzers in the AII range, so technicians who learn one instrument can move between them without retraining.

Seven Star LLC supplies the AII GPR-1500 to process plants, gas producers and engineering contractors across the Sultanate of Oman and the wider GCC, with engineering support in Muscat. Our team helps buyers choose the right sensor variant, measurement range and area classification before the order is placed, so the transmitter arrives ready for the nitrogen package, inerting skid or purity monitoring point it is meant to serve, whether that is in Muscat, Sohar, Duqm or Salalah.

Measurement Principle of the AII GPR-1500

As general engineering background, an electrochemical (galvanic) oxygen sensor works like a small fuel cell. Oxygen in the sample diffuses through a membrane to a cathode, where it is reduced; a consumable anode inside the cell is oxidised at the same time, and the resulting current is directly proportional to the partial pressure of oxygen at the sensing face. Because the cell generates its own signal, no heated element, pump or reference gas is needed, and the output is close to zero when no oxygen is present, which is what makes this technology well suited to trace measurement in nitrogen, argon and other inert streams.

In the AII GPR-1500, AII pairs this principle with its own long-life ppm sensors that the company has refined over more than three decades. The datasheet lists the GPR-12-333 family (including the -LD and -H variants) and the XLT-12-333 family for colder sites, and sensor options allow oxygen to be measured in backgrounds such as helium, hydrogen or carbon dioxide. Gas temperature compensation is built in, a span check can be carried out with an air or span gas up to 0–25 % (a calibration-only range), and the response time to 90 % of a step change is stated as under two minutes for the ppm sensor.

Engineering Design of the AII GPR-1500

The transmitter is housed in a wall-mounted enclosure of fibreglass and painted aluminium rated NEMA 3R, with an LCD readout and a simple keypad visible through the window. Sample gas is connected at the side fittings and should be supplied at 5–30 psi (about 0.4–2.1 bar) with a flow of 1–2 SCFH (0.5–1 L/min), as specified by the manufacturer. The sensor sits in a dedicated flow housing behind the window, so a replacement can be fitted in minutes without disturbing the wiring.

Electrically, the AII GPR-1500 is a two-wire, loop-powered device: an 18–24 V DC supply drives the 4–20 mA output, and maximum consumption is only 1.8 W. That low power budget is what allows the hazardous-area version to carry intrinsic-safety approvals for Zone 0, while the general-purpose version simply connects to a standard PLC, DCS or SCADA analog input. Compliance listed in the datasheet includes the EMC Directive 2014/30/EU (EN 50270:2015 and EN 61000-4-2:2009) and UL/IEC/EN 61010-1.

Key Features

The main reasons engineers specify the AII GPR-1500 for trace oxygen duty are summarised below.

  • Four selectable full-scale ranges of 0–10, 0–100 and 0–1000 ppmV plus 0–1 % cover everything from high-purity nitrogen to blanketing gas checks.
  • A lower detection limit of 0.05 ppmV and 0.01 ppmV output resolution give meaningful readings at the bottom of the lowest range.
  • Loop-powered 4–20 mA operation from 18–24 V DC keeps installation to a single two-core cable.
  • Hazardous-area versions are certified ATEX II 1 G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4 Ga and cMETus Class I, Division 1, Groups A, B, C and D.
  • Sensor options allow oxygen measurement in helium, hydrogen or carbon dioxide background gases.
  • Gas temperature compensation stabilises readings as ambient and sample temperatures change during the day.
  • Expected ppm sensor life is up to 24 months in gas below 1000 ppmV, application dependent, which keeps running costs low.
  • A common HMI shared across AII online and portable analyzers shortens training for maintenance crews.

Industrial Applications

In the Gulf region the AII GPR-1500 is a natural fit for nitrogen generators and PSA packages at refineries, gas plants and LNG facilities, where the purity of the nitrogen used for purging and blanketing must be proved continuously. The manufacturer also lists inertization and blanketing gases, natural gas quality, oxygen in pharmaceutical reactors and centrifuges, steel production and heat-treatment furnaces, solder re-flow lines and feed-gas purity for food and beverage packaging. Those last applications match the growing food processing and packaging investment in the Sohar and Salalah free zones, where modified-atmosphere packaging lines depend on low residual oxygen.

Specialty gas fillers, glove-box operators and laboratories are another strong match, because the 0–10 ppmV range and the low detection limit suit high-purity argon and nitrogen checks. Seven Star LLC supplies the AII GPR-1500 with sensor variants, spare sensors and calibration accessories for these users throughout Oman and the GCC, and our Muscat engineers can advise on sample conditioning when the gas carries moisture or particulates. For comparison with other technologies on our site, see the Servomex NanoTrace DF-550E ultra-trace oxygen analyzer, the Teledyne 3000RS online oxygen analyzer and the Systech ZR810 zirconia oxygen analyzer.

Technical Specifications

The figures below for the AII GPR-1500 are taken from the AII GPR-x500 datasheet (PST-DS-3002-00, 07/2024); performance is application dependent.

Parameter Specification
Model AII GPR-1500 trace (ppm) oxygen transmitter, GPR-x500 series
Sensor type Electrochemical; GPR-12-333, GPR-12-333-LD, GPR-12-333-H, XLT-12-333, XLT-12-333-LD
Measuring ranges 0–10, 0–100, 0–1000 ppmV, 0–1 %; 0–25 % for calibration only
Output resolution 0.01 ppmV
Lower detection limit 0.05 ppmV
Response time (T90) Less than 2 minutes
Sample flow rate 1–2 SCFH (0.5–1 L/min), application dependent
Pressure range 5–30 psi (0.4–2.1 bar)
Operating temperature +5 to +45 °C (GPR sensors); −10 to +45 °C (XLT sensors)
Humidity 0–80 %rh, non-condensing
Sensor life expectancy 24 months in gas below 1000 ppmV (application dependent)
Calibration interval 30 days (application dependent)
Display / output LCD / 4–20 mA
Power supply 18–24 V DC, maximum 1.8 W
Enclosure NEMA 3R, fibreglass and painted aluminium, wall mounting
Hazardous area ATEX II 1 G Ex ia IIC T4 Ga; IECEx Ex ia IIC T4 Ga; cMETus Class I Div 1 Groups A–D T4, Class I Zone 0 AEx ia IIC T4 Ga; Tamb −20 to +50 °C

How to Order

To specify the AII GPR-1500 for your plant, send Seven Star LLC a formal RFQ with the background gas, required range, area classification and sample conditions, and our instrumentation division will confirm the correct sensor and configuration. Download the manufacturer datasheet from this page for full details, and contact our Muscat office for availability, lead time and engineering support anywhere in Oman and the GCC.

Datasheets & Documents
  • PDF datasheet AII GPR-x500 Oxygen Analyzers Datasheet (PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Analytical Industries Inc. (AII) is an American maker of electrochemical oxygen sensors and gas analysers, based in Pomona, California. It was incorporated in 1994 by three former Teledyne executives. AII makes percent, ppm and ppb oxygen analysers and ppm hydrogen sulphide analysers, and has supplied oxygen sensors for US Navy rebreathers since 1998.

Seven Star LLC is an independent supplier in Muscat. We list AII analyzers for gas processing and industrial users in Oman and the GCC.

Analytical Industries (AII) company profile

Incorporated 1994, California
Founders Three former Teledyne executives
Headquarters Pomona, California
Markets Industrial, medical and diving
Product families GPR-1500, GPR-1800 and GPR-18 trace ppm oxygen analysers, GPR-2500 percent oxygen analysers, GPR-7500 H2S analysers, galvanic oxygen sensors

Analytical Industries product series

Oxygen instruments include the GPR-1500 trace ppm oxygen transmitter, the GPR-2500 percent oxygen analyzer, the GPR-18 explosion-proof trace oxygen analyzer and the GPR-1800 (A)IS hazardous area trace oxygen analyzer.

The GPR-7500 (A)IS measures hydrogen sulphide.

Galvanic fuel cell sensors measure oxygen from trace ppm levels to percent, and the analyzers are offered in general purpose, explosion-proof and intrinsically safe versions. Sample conditions such as pressure, flow and contaminants affect sensor life and must be checked before selection.

H2S analyzers monitor sour gas content in natural gas and fuel gas.

Where AII analyzers are used

Natural gas processing, inert gas blanketing, nitrogen generators, gas purity and safety monitoring.

Analytical Industries (AII) products we list

Family Examples
Gas Analyzer Systems AII GPR-1500 Trace ppm Oxygen Transmitter, AII GPR-18 Explosion-Proof Trace Oxygen…, AII GPR-1800 (A)IS Hazardous Area Trace…, AII GPR-2500 Percent Oxygen Analyzer, AII GPR-7500 (A)IS Hydrogen Sulphide Ana…

Ordering AII analyzers: what we need

Send the model, range, sample gas composition and conditions, area classification and outputs required.

Facts checked against Analytical Industries' company profile and distributor listings, October 2026.

FAQ

Questions about the AII GPR-1500 Trace ppm Oxygen Transmitter

Answers from our engineering team on installation, compatibility and integration.

01What oxygen ranges does the AII GPR-1500 measure?
The AII GPR-1500 offers full-scale ranges of 0-10, 0-100 and 0-1000 ppmV and 0-1 % oxygen, with 0-25 % available for calibration only. The datasheet gives a lower detection limit of 0.05 ppmV and a resolution of 0.01 ppmV.
02Can the AII GPR-1500 be installed in a hazardous area?
Yes. Hazardous-area versions are certified ATEX II 1 G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4 Ga and cMETus Class I, Division 1, Groups A, B, C and D, for ambient temperatures from -20 to +50 degrees C. A general-purpose version is available for safe areas.
03How is the AII GPR-1500 powered and wired?
It is a loop-powered transmitter supplied with 18-24 V DC that delivers a 4-20 mA signal, with a maximum consumption of 1.8 W. This lets it connect directly to a PLC, DCS or SCADA analog input over a single two-core cable.
04Can it measure oxygen in hydrogen, helium or carbon dioxide?
Sensor options are offered for oxygen measurement in helium, hydrogen or carbon dioxide background gases. Note that the instrument measures oxygen in those gases; it is not a carbon dioxide sensor. Tell us the background gas when you request a quote so the correct sensor is fitted.
05Does Seven Star LLC supply the AII GPR-1500 in Oman?
Seven Star LLC supplies the AII GPR-1500, replacement sensors and accessories to customers in Oman and the GCC, with engineering support from Muscat. Send us your application details for a formal quotation.