Applied Analytics OMA-206P Portable UV-Vis Process Analyzer

Description

Overview

The Applied Analytics OMA-206P is a transportable, suitcase-enclosed version of the proven OMA-series dispersive UV-Vis/SW-NIR process analyzer platform, built for engineers who need laboratory-grade spectrophotometric analysis at the point of measurement rather than back in a fixed control room. Housed in an ultra-high-impact structural copolymer case measuring 428mm × 524mm × 206mm and weighing only 11kg, the Applied Analytics OMA-206P lets a technician carry a full multi-component UV-Vis analyzer from unit to unit, well to well, or site to site, verifying online analyzer readings, troubleshooting a suspect measurement loop, or running a temporary monitoring campaign without installing a permanent instrument. Because it shares its detector, optics, and fiber-optic sampling architecture with the wall-mounted OMA-300 platform, results carry the same accuracy and repeatability that plant chemists already trust from the fixed installation.

With engineering support in Muscat, Seven Star LLC supplies the OMA-206P to refineries, gas plants, and petrochemical operators across the Sultanate of Oman and the wider GCC. Every unit supplied through Seven Star LLC comes with manufacturer documentation and access to regional technical support.

Operating Principle

The OMA-206P uses dispersive ultraviolet-visible and short-wave near-infrared absorbance spectrophotometry to identify and quantify chemical species in a sample stream. A pulsed xenon lamp with an approximate five-year service life illuminates the sample through 1.8-meter, 600μm-core fiber optic cables, and a nova II diode array detector captures the resulting absorbance spectrum across a 200–800nm range at every integer wavelength. Because each chemical compound produces a distinctive absorbance signature, a deconvolution algorithm resolves the total sample spectrum into up to five individual analyte concentrations simultaneously, referencing a regression matrix built from hundreds of calibration data points rather than a single fixed wavelength.

Carrying light to the sample through fiber optics – instead of drawing a hazardous or explosive sample into the electronics enclosure – is the defining safety advantage of this measurement principle. The flow cell, not the analyzer chassis, ever touches the process fluid, and because the design is entirely solid-state there are no moving parts, filter wheels, or optical chopper assemblies to wear, drift, or foul. The practical result for a portable field instrument is a fast one-to-five-second response, minimal recalibration burden between deployments, and confidence that a spot reading taken on a suitcase unit will match what a permanent OMA analyzer would report on the same stream.

Engineering Design of the Applied Analytics OMA-206P

Every wetted component in the Applied Analytics OMA-206P’s flow path – the sample cell body, fittings, and seals – is constructed from quartz, Viton, and 316L stainless steel, giving the portable unit the same chemical compatibility and corrosion resistance expected from a permanently installed OMA-series analyzer. The OMA-206P suitcase enclosure is purpose-built rather than a repurposed shipping case: its structural copolymer shell is rated for genuine field abuse – vehicle transport, dock handling, occasional drops – while still protecting the internal optical bench, detector, and electronics from vibration and dust ingress between deployments.

Inside, the layout mirrors the fixed OMA platform’s architecture: the xenon lamp, fiber-optic launch assembly, and nova II diode array spectrophotometer sit on a common optical bench, with fiber-optic jumpers running out to an external flow cell that the technician connects at the sample point. Standard 4-20mA analog outputs plus digital relay contacts are provided as-shipped, with Modbus TCP/IP, RS-232/RS-485, Fieldbus, Profibus, and HART available as configured options for logging a field campaign directly into a data acquisition laptop or portable historian. Power is universal 85–264 VAC, 47–63Hz, so the unit runs from site generator power or a standard outlet without a step-down transformer.

Key Features

The Applied Analytics OMA-206P brings genuine multi-component spectrophotometric analysis into a field-portable package. Its principal capabilities include:

  • The Applied Analytics OMA-206P measures up to five chemical species simultaneously in a single sample stream using dispersive UV-Vis/SW-NIR spectrophotometry across a 200–800nm range.
  • The OMA-206P’s rugged, ultra-high-impact suitcase enclosure weighing only 11kg allows one technician to transport the full analyzer between sites, wells, or process units without a lifting crew.
  • Fiber-optic sample transmission keeps the hazardous or explosive process fluid entirely outside the analyzer electronics, isolating risk at the external flow cell.
  • The solid-state nova II diode array detector and pulsed xenon lamp deliver a 1-to-5-second response with no moving optical parts to wear or misalign.
  • Wetted materials of quartz, Viton, and 316L stainless steel provide broad chemical compatibility for refinery, gas plant, and petrochemical sample streams.
  • Standard 4-20mA and relay outputs are supplemented by optional Modbus TCP/IP, RS-232/RS-485, Fieldbus, Profibus, and HART connectivity for direct integration with field data loggers.
  • The Applied Analytics OMA-206P accepts universal 85–264 VAC power input, letting the unit run from generator power, a site UPS, or standard mains without additional conditioning equipment.
  • Shared detector and optical architecture with the permanently installed OMA-300 platform means field verification readings correlate directly with fixed-analyzer performance.

Industrial Applications

Facility engineers across Oman’s oil, gas, and petrochemical sector deploy the Applied Analytics OMA-206P wherever a fixed analyzer is impractical but laboratory-grade accuracy is still required: verifying a permanently installed OMA-300 or OMA-series analyzer’s calibration during a turnaround, running a temporary monitoring campaign on a new or suspect process stream, or troubleshooting an out-of-specification reading without shutting down the primary loop. Refinery process engineers deploy the Applied Analytics OMA-206P to spot-check sulfur, hydrocarbon, or contaminant levels at multiple sample points in a single shift, while gas plant technicians carry it between wellheads and gathering stations for compositional verification work that would otherwise require sending samples off-site to a laboratory and waiting days for results.

Backed by manufacturer datasheet documentation, Seven Star LLC distributes the Applied Analytics OMA-206P to operators throughout Muscat, the Sohar Industrial Port, the Salalah Free Zone, and refining and petrochemical hubs across the wider GCC.Seven Star LLC supplies this item on request with the manufacturer documentation, and availability and lead time are confirmed at quotation.

Technical Specifications

The table below summarizes the principal specifications of the Applied Analytics OMA-206P portable process analyzer.

Parameter Specification
Model Applied Analytics OMA-206P
Measurement Principle Dispersive UV-Vis / SW-NIR absorbance spectrophotometry
Detector nova II UV-Vis diode array spectrophotometer
Spectral Range 200–800 nm
Light Source Pulsed xenon lamp, ~5-year lifespan
Simultaneous Analytes Up to 5 chemical species
Response Time 1–5 seconds
Fiber Optic Cable 600μm core, 1.8 m standard length
Wetted Materials Quartz, Viton, 316L stainless steel
Enclosure Ultra-high-impact structural copolymer suitcase
Dimensions 428 × 524 × 206 mm (16.87″ H × 20.62″ W × 8.12″ D)
Weight 11 kg (25 lbs)
Power Supply 85–264 VAC, 47–63 Hz, 45 W
Standard Outputs 4–20 mA analog, digital relay
Optional Outputs Modbus TCP/IP, RS-232/RS-485, Fieldbus, Profibus, HART

Request a Quote for Applied Analytics OMA-206P Portable UV-Vis Process Analyzer

Facility engineers and procurement teams evaluating the Applied Analytics OMA-206P analyzer for a field verification program, turnaround support, or a temporary monitoring campaign are invited to submit a formal RFQ through Seven Star LLC’s instrumentation division. Working closely with plant engineers in the region, Seven Star LLC supplies on request with lead time confirmed at quotation, provides full technical datasheets on request, and coordinates calibration and support questions directly with the manufacturer. Contact the Seven Star LLC instrumentation team today to confirm lead times, request the complete Applied Analytics OMA-206P datasheet, and place an order for delivery across Muscat, Sohar, Salalah, and the wider GCC region.

Browse the full Applied Analytics range or see more Gas Analyzer Systems products supplied by Seven Star LLC in Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet Applied Analytics OMA-206P Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Applied Analytics is an American manufacturer of industrial process analyzers, founded in 1994 and based in Burlington, Massachusetts. Its founders set out to apply UV-Vis spectrophotometry, then used mainly in medicine and research, to heavy industry, especially oil and gas. Its OMA analyzers read a full absorbance spectrum of the process stream with a solid-state design, and the company builds the sample conditioning system for each application in the USA.

Seven Star LLC lists Applied Analytics OMA analyzers for H2S, chlorine, BTX, odorant and multi-stream duty, and supplies them to gas plants, refineries and chemical sites in Oman as an independent supplier.

Applied Analytics company profile

Founded 1994, USA
Headquarters Burlington, Massachusetts
Technology Full-spectrum UV-Vis and NIR absorbance spectroscopy
Manufacturing Analyzers and sample systems built in the USA
Product families OMA-300 wall-mount, OMA-406R rackmount and OMA-206P portable analyzers for H2S, chlorine, BTX and odorant, TLG-837 tail gas and air demand analyzer, TSA-200 total sulfur analyzer, oil-in-water analyzers

Applied Analytics OMA analyzers on this page

The manufacturer offers the OMA in three form factors: the wall-mounted OMA-300, the portable OMA-206P and the rackmount OMA-406R. All three are listed here, with application-specific builds of the same platform:

  • OMA-300 H2S Analyzer and OMA-300 Multi-Stream Process Analyzer
  • OMA Chlorine, BTX and Odorant analyzers
  • OMA-300-InGaAs for near-infrared measurements

The company also makes the TLG-837 tail gas analyzer, a sulfur pit gas version of it, and sample conditioning systems designed for each project.

Where Applied Analytics analyzers are used

Typical duties are H2S in sour gas, acid gas and amine treating, sulfur recovery control, chlorine in chlor-alkali and water treatment, aromatics in hydrocarbon and wastewater streams, and mercaptan odorant in distribution gas. These are everyday measurements in GCC gas processing and refining.

Applied Analytics products we list

Family Examples
Gas Analyzer Systems OIW-100 Oil in Water Analyzer, OMA BTX Analyzer, OMA Chlorine Analyzer, OMA Odorant Analyzer, OMA-206P Portable UV-Vis Process Analyzer, OMA-300 H2S Analyzer, OMA-300 Multi-Stream Process Analyzer, OMA-300-InGaAs Process Analyzer and 3 more

Ordering an OMA analyzer: what we need

An OMA is configured for one stream, so the manufacturer needs process data before it can confirm a model. Send the stream composition with all components and their ranges, the analytes and measuring ranges, phase, pressure and temperature at the sample point, area classification, available utilities, required outputs and whether a sample conditioning system or shelter is part of the scope. For spares, send the analyzer serial number and the part description.

Facts checked against Applied Analytics company material and industry directory profiles, October 2026.

FAQ

Questions about the Applied Analytics OMA-206P Portable UV-Vis Process

Answers from our engineering team on installation, compatibility and integration.

01What does the Applied Analytics OMA-206P measure?
The OMA-206P is a portable dispersive UV-Vis/SW-NIR process analyzer that simultaneously measures up to five chemical species in a liquid or gas sample stream, using the same detector and optical architecture as the fixed OMA-300 platform.
02Can the OMA-206P replace a permanently installed process analyzer?
No. It is designed for field verification, spot-checks, turnaround support, and temporary monitoring campaigns alongside a permanent installation, not as a full-time replacement for a fixed OMA-series analyzer.
03What sample conditions can the OMA-206P handle?
The flow cell is built from quartz, Viton, and 316L stainless steel, and standard units accommodate ambient temperatures of 0-35 degrees Celsius, with optional configurations extending sample temperature range for harsher field conditions.
04What output signals does the OMA-206P provide for data logging?
Standard 4-20mA analog and digital relay outputs are included, with Modbus TCP/IP, RS-232/RS-485, Fieldbus, Profibus, and HART available as configured options for direct integration with a laptop, historian, or portable data logger.
05Is Seven Star LLC an experienced supply partner for Applied Analytics products?
Yes. Seven Star LLC supplies Applied Analytics products to customers in Oman and the GCC and can provide the manufacturer documentation and technical support on request.