Brand: AMETEK
AMETEK Thermox WDG-V Flue Gas Oxygen Analyzer
Description
Overview
The AMETEK WDG-V is a Thermox flue gas oxygen analyzer from AMETEK Process Instruments, designed to measure excess oxygen in combustion exhaust and to add a further layer of safety to the burner management system. It uses a close-coupled extractive design, drawing a small flue gas sample through a heated cell mounted directly at the stack or firebox wall, which gives a fast response across a wide range of applications with flue gas temperatures up to 1648 °C. With SIL 2 capability for excess O2, it can be used inside a safety instrumented system as well as for everyday combustion optimisation.
Refineries, gas plants, petrochemical complexes, power stations and desalination plants in Oman and the GCC operate large numbers of fired heaters, steam boilers and thermal oxidizers, where tight oxygen control saves fuel, limits emissions and prevents unsafe fuel-rich firing. Seven Star LLC supplies the AMETEK WDG-V to these users, with engineering support in Muscat for selection, probe sizing and spare parts.
Measurement Principle
The AMETEK WDG-V measures oxygen with a zirconium oxide cell held at a high, controlled temperature. At that temperature the ceramic conducts oxygen ions, and the difference in oxygen partial pressure between the flue gas on one side of the cell and a reference gas on the other generates a voltage that follows the Nernst equation. The electronics convert that voltage to percent oxygen, giving output ranges selectable from 0–1% up to 0–100% O2 with accuracy of ±0.75% of measured value or ±0.05% O2, whichever is greater.
An air- or nitrogen-driven aspirator, consuming about 3 SCFH at 3 to 6 psig, pulls sample gas from the probe past the cell and returns it to the process, so no sample is vented and no pump is needed. An integral flow sensor in the AMETEK WDG-V checks that sample is actually moving, and continual diagnostics track cell and detector age, cell resistance and analog current integrity. Response to a step change reaches 90% in under 11 seconds even with flame arrestors fitted.
Engineering Design of the AMETEK WDG-V
The AMETEK WDG-V is housed in a hinged, weather-resistant stainless steel IP65 (NEMA 4X) enclosure. Probe options are matched to flue gas temperature: 316 stainless steel probes for up to 704 °C and 310 stainless probes for up to 1024 °C, both in lengths from 910 to 2740 mm, and Hexoloy silicon carbide probes for up to 1648 °C in lengths from 600 to 1820 mm. Versatile flange options suit most stack and furnace connections. The AMETEK WDG-V handles sample dew points up to 200 °C and sample pressures of ±10 in. water gauge, and operates in ambient temperatures from −25 to 65 °C (−20 to 60 °C in hazardous areas).
For signals, the AMETEK WDG-V provides three isolated, fully scalable current outputs (4–20, 0–20, 20–4 or 20–0 mA, NAMUR configurable), five independent alarm relays and two-wire Modbus RTU, with HART available as an option. The optional AMEVision HMI adds a 4.2-inch colour display and can host up to eight analyzers, passing data to plant networks over Modbus or Ethernet TCP/IP with an embedded web server. Purged, remote-mount and floor-mount versions cover Class I Division 2 and ATEX or IECEx Zone 2 locations, and timed automatic calibration is possible with the optional Remote Calibration Unit.
Key Features
The points below explain why combustion engineers specify the AMETEK WDG-V for fired equipment.
- SIL 2 capability for excess O2 allows use in SIS combustion safety systems, supported by predictive diagnostics and proactive alarms.
- An industry-proven zirconium oxide sensor delivers accurate oxygen readings across ranges from 0–1% to 0–100%.
- The close-coupled extractive layout responds quickly, reaching 90% of a step change in under 11 seconds.
- An integral flow sensor verifies sample system integrity so a blocked probe cannot pass unnoticed.
- Probe materials up to Hexoloy silicon carbide handle flue gas temperatures up to 1648 °C.
- Three isolated analog outputs, five alarm relays, Modbus RTU and an optional HART interface simplify DCS integration.
- Ethernet connectivity through AMEVision enables remote monitoring from maintenance LANs or asset management systems.
- The analyzer is completely field-serviceable, which shortens repair time at remote sites.
Industrial Applications
In Oman’s refining and petrochemical sector, the AMETEK WDG-V is suited to crude and vacuum heaters, reformer and hydrotreater furnaces, steam methane reformers and ethylene cracking furnaces, where operators trim combustion air to the lowest safe excess oxygen to cut fuel use and NOx formation. Because the analyzer can feed a SIL-rated burner management system, it also helps protect fired heaters from dangerous low-oxygen conditions during load changes or burner faults. Gas plants and LNG facilities use the AMETEK WDG-V on regeneration heaters, hot oil heaters and thermal oxidizers that destroy acid gas and vent streams.
Power and water utilities across the GCC apply the AMETEK WDG-V to auxiliary and heat-recovery boilers and to steam generators that serve thermal desalination plants, while industrial users in Sohar, Duqm and Salalah fit it to process boilers, kilns and incinerators. Seven Star LLC supplies the AMETEK WDG-V with suitable probes, flame arrestors, calibration units and spare cells, and provides engineering support in Muscat for project and maintenance needs.
Technical Specifications
The key AMETEK WDG-V data below come from the manufacturer’s product data sheet (F-0510).
| Parameter | Specification |
|---|---|
| Model | AMETEK Thermox WDG-V |
| Principle | Zirconium oxide, excess O2 |
| Output range | 0–1% to 0–100% O2 |
| Accuracy | ±0.75% of measured value or ±0.05% O2, whichever is greater |
| Response | 90% of step change < 11 s with flame arrestors |
| Safety | SIL 2 capable for excess O2 |
| Aspirator air | 3 SCFH typical at 3–6 psig, instrument air or N2 |
| Analog outputs | 3 isolated, 4–20 / 0–20 / 20–4 / 20–0 mA, NAMUR configurable, max. load 1200 Ω |
| Alarms | 5 independent NO relays, 0.5 A, 30 V, 10 W max. |
| Digital communication | Two-wire Modbus RTU 57.6 kBaud; HART option; Ethernet TCP/IP via AMEVision |
| Diagnostics | Low sample flow, cell and detector age, cell resistance, calibration required, analog current verification |
| Sample pressure | ±10 in. water gauge |
| Max. sample dew point | 200 °C |
| Probes | 316 SS to 704 °C and 310 SS to 1024 °C (910–2740 mm); Hexoloy to 1648 °C (600–1820 mm) |
| Ambient temperature | −25 to 65 °C; −20 to 60 °C hazardous areas; 5–95% RH non-condensing |
| Enclosure | Hinged stainless steel IP65 (NEMA 4X); purged, remote and floor mount versions |
| Hazardous area | UL Class I Div 2 Gp B, C, D; ATEX II 3 G and IECEx Ex pz versions with purge |
| Power | 115 or 230 VAC ±10%, 47–63 Hz, 740 VA max. |
| Calibration gas | 10 psig, 1.5 SCFH; span air or 1–100% O2; zero 0.1–10% O2 in N2 |
Related AMETEK Products
Plants running sulfur recovery or gas processing units can also review the AMETEK 900 tail gas air demand analyzer, AMETEK 5100P transportable TDLAS analyzer and AMETEK 7000-330-SE LCD host interface PCB.
How to Order
To order the AMETEK WDG-V, send Seven Star LLC a formal RFQ with flue gas temperature, probe length, mounting flange, hazardous-area classification and whether SIL 2 or HART is required. Our instrumentation team will confirm the configuration, current availability and delivery to sites in Oman and the GCC. The product datasheet can be downloaded from this page, and our engineers in Muscat can advise on calibration units, spare cells and integration with your burner management system.
See also: AMETEK 300-2070 Cadmium Hollow Cathode Lamp (AAS Cd).
Datasheets & Documents
- Datasheet AMETEK WDG-V Flue Gas Oxygen Analyzer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.
Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.
AMETEK company profile
| Established | 1930, USA, as American Machine and Metals; later renamed AMETEK |
|---|---|
| Headquarters | Berwyn, Pennsylvania |
| Structure | Two groups: Electronic Instruments (EIG) and Electromechanical (EMG) |
| Process brands | Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex |
Milestones
- 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
- Early 1960s: The company is renamed AMETEK.
- 2021: AMETEK acquires Magnetrol.
AMETEK products we list
| Product | Type | Typical use |
|---|---|---|
| 888, 900, 930 | Western Research sulfur recovery analysers | Tail gas, air demand and H2S in sulfur pits on Claus units |
| 931, 933, 9900RM/WM | UV gas analysers | H2S in natural gas and multi-component process streams |
| 5000, 3050-OLV, 5100HD, 5100P | Moisture analysers | Water content in natural gas and process gases; the 5100 models use TDLAS |
| 241CE II, Chanscope II / Model 13 | Dew point analysers and testers | Hydrocarbon and water dew point of natural gas |
| WDG 1200/1210, WDG-V, TM2000 | Thermox oxygen analysers | Combustion control on heaters and boilers, and trace oxygen |
| SPOT+, Cyclops L | Land pyrometers | Non-contact temperature of furnaces, kilns, tubes and hot metal |
| 120HD, Ranarex, Drexelbrook RCT-1210 | Portable analysers and level | Hydrogen purity in generators, gas specific gravity, RF level measurement |
Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.
Where AMETEK instruments are used
In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.
Ordering AMETEK products: what we need
Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.
Facts checked against AMETEK company history, October 2026.
Browse AMETEK products by category: Gas Analyzer Accessories, Gas Analyzer Systems, Liquid Analytical Accessories, Level Transmitter.
FAQ
Questions about the AMETEK Thermox WDG-V Flue Gas Oxygen Analyzer
Answers from our engineering team on installation, compatibility and integration.
01Can the AMETEK WDG-V be used in a safety instrumented system?
Yes. The AMETEK WDG-V is SIL 2 capable for excess oxygen measurement and can be used in SIS combustion safety systems. Onboard diagnostics give a low probability of undetected faults, and Modbus or Ethernet communication reports diagnostics and calibration status to the safety system.
02What flue gas temperatures can the AMETEK WDG-V handle?
Probe choice sets the limit: 316 stainless steel probes for up to 704 C, 310 stainless probes for up to 1024 C, and Hexoloy silicon carbide probes for up to 1648 C. Probe lengths range from 600 to 2740 mm depending on material.
03How fast and accurate is the AMETEK WDG-V oxygen reading?
Accuracy is plus or minus 0.75 percent of measured value or 0.05 percent O2, whichever is greater. The analyzer reaches 90 percent of a step change in under 11 seconds even with flame arrestors fitted, thanks to its close-coupled extractive design.
04What outputs and communications does the AMETEK WDG-V provide?
It has three isolated, scalable current outputs, five alarm relays and two-wire Modbus RTU, with HART available as an option. The optional AMEVision HMI adds a colour display, hosts up to eight analyzers and connects to plant networks via Ethernet TCP/IP.
05Does Seven Star LLC supply the AMETEK WDG-V in Oman and the GCC?
Yes. Seven Star LLC supplies the AMETEK WDG-V, probes, calibration units and spare parts to refineries, gas plants, power stations and industrial users in Oman and the GCC. As a trusted supplier we provide engineering support in Muscat.


















Reviews