Brand: Speakman
Speakman Eyesaver SEF-1000 Laboratory Faucet with Eyewash
Description
The Speakman Eyesaver SEF-1000 combines a fully working laboratory faucet spout with an independently operated emergency eyewash in a single deck-mounted fitting. The patented body has two separate water channels, one for the faucet and one for the eyewash, so the emergency water arrives at a tepid temperature when the eyewash is supplied from a tempered source. The spout swivels, the brass body is finished in polished chrome, and a lift-activated eyewash handle is large enough to be found quickly.
It is the type of fitting installed on laboratory benches, sinks in water testing laboratories, workshops and first-aid rooms, where a full eyewash station would take too much space but flushing equipment is still needed beside the work area.
Technical specification
| Parameter | Specification |
|---|---|
| Model / order code | SEF-1000 (Eyesaver Classic eyewash faucet spout) |
| Installation type | Counter mounted, single hole, integral swivel |
| Water channels | Two independent supplies: faucet and eyewash |
| Faucet flow | 1.2 gpm (4.54 L/min) |
| Eyewash flow | Page: 2.4 gpm at 30 psi (spec block) and 2.0 gpm at 30 psi (feature bullet) |
| Eyewash heads | Dual aerated spray heads with flip-top dust covers |
| Eyewash activation | Lift-activated handle |
| Connection | 3/8 in compression for faucet and eyewash; hoses supplied (12 in) |
| Spout dimensions (page) | Height 9.26 in; length 8.35 in; reach 5.44 in |
| Maximum deck thickness | 2 in |
| Operating pressure range (sheet) | 20 to 80 psi; eyewash minimum 30 psi flowing |
| Finish / material | Polished chrome; low lead brass |
| Certifications (page) | ANSI/ISEA Z358.1; ASME A112.18.1/CSA B125.1; IGC 272; NSF/ANSI 61; NSF/ANSI 372 |
| Warranty (page) | 3 year limited (commercial) |
| Aerator spare | 1.2 gpm Slim Air aerator repair group RPG05-111352 |
Selection and ordering guide
The sheet covers several Eyesaver models, so confirm the exact code and the faucet center (the page lists 6 to 6 centers and a single hole). A tepid water supply is expected for the eyewash; Speakman recommends its STW-370 thermostatic mixing valve, which is not included, and says to flush the tepid supply into a bucket for one minute before connecting. If shut-off valves are installed in the eyewash supply, the sheet says provision must be made to prevent unauthorized shut off. Inlet supplies are not included.
Installation notes
Shut off the water, remove any existing faucet spout, clean the mounting surface, check the rubber gasket and lower the spout into position, feeding the hoses one at a time through the hole. From below fit the rubber washer, metal washer and nut, verify the swivel sweep and tighten the mounting nut screws. Assemble the tee to the faucet inlet, connect the flex hoses to the existing valve bodies, and connect the tepid water to the eyewash inlet. The valve bodies and handles are not included. Clean with a soft cloth only: harsh chemicals and abrasives can damage the finish and void the warranty. ANSI Z358.1 requires weekly testing and annual inspection, per the sheet.
Applications in GCC industry
This faucet fits laboratory benches in refinery QC and petrochemical labs, desalination and wastewater test laboratories, university and hospital labs, and workshops with a sink. Because the eyewash is plumbed from the building water line, the water temperature in hot climates needs control; the tepid-water recommendation in the sheet and a mixing valve address that, and the site HSE team should define the limits.
Before ordering, confirm the deck thickness, which the page limits to a maximum of 2 in, and the supply pressure of 20 to 80 psi given on the sheet. Keep the 1.2 gpm Slim Air aerator repair group RPG05-111352 in mind as the listed spare for the faucet side of the fitting.
Installation and selection notes
Deck-mount the fitting on a bench or sink with the two water supplies connected correctly, one for the faucet and one for the eyewash, as shown in the installation drawing. Test the eyewash regularly, record the test and keep the area around it clear. Where tepid water is required by the site standard, plan a tempered supply.
Information needed for a quotation
Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any hoses, couplings or accessories needed, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification before a purchase is confirmed. Ratings, flows, pressures and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Related Speakman products: Speakman Optimus SE-1200 Emergency Shower with Eye/Face Wash, Speakman GravityFlo SE-4000 21-Gallon Portable Eyewash, Speakman Optimus SE-1050 Wall-Mount Eye and Face Wash, Speakman Lifesaver SE-220 Vertical Emergency Deluge Shower, Speakman GravityFlo SE-8000 528-Gallon Emergency Tank Shower and Speakman SE-590 10-Gallon Portable Eyewash with Drench Hose.
Documents and quotation
The Speakman installation sheet 92-SEF-1000-07 for the Eyesaver SEF-1000 is attached to this page. Browse more products in Safety & PPE. Seven Star LLC is an independent supplier in Muscat; send the exact part number and quantity for a quotation, and confirm all ratings and approvals against the current manufacturer documents before ordering.
Datasheets & Documents
- Manual Eyesaver SEF-1000 Installation Instructions (92-SEF-1000-07) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Speakman is an American maker of showers, faucets and emergency safety equipment, founded in 1869 when the brothers Allen and Joseph Speakman opened a plumbing workshop in Wilmington, Delaware. The company is credited with the first adjustable shower head, received its first single-handle faucet patent in 1906, and began expanding into emergency showers and eyewash units in 1960. Speakman is headquartered in New Castle, Delaware.
Seven Star LLC is an independent supplier in Muscat. We list Speakman emergency equipment for plants, laboratories and workshops in Oman and the GCC.
Speakman company profile
| Founded | 1869, Wilmington, Delaware |
|---|---|
| Founders | Allen and Joseph Speakman |
| Headquarters | New Castle, Delaware |
| Safety line | Emergency showers and eyewash, since 1960 |
| Product families | Traditional, Select and Optimus combination emergency showers and eye/face washes, Lifesaver deluge showers, GravityFlo self-contained tank showers and portable eyewash units, tempered water systems |
Milestones
- 1869: Allen and Joseph Speakman open their workshop.
- 1906: Speakman receives its first single-handle faucet patent.
- 1960: Speakman expands into emergency showers and eyewash.
Speakman product series
Plumbed units include the Lifesaver SE-220 vertical deluge shower, the Select SE-603 and Traditional SE-626-SS combination showers with eye/face wash, the Optimus SE-1200 shower with eye/face wash and the Optimus SE-1050 wall-mounted eye and face wash. The Eyesaver SEF-1000 is a laboratory faucet with eyewash.
Self-contained units include the GravityFlo SE-4000 21-gallon portable eyewash, the SE-590 10-gallon portable eyewash with drench hose and the GravityFlo SE-8000 528-gallon tank shower for sites without plumbed water.
Where Speakman equipment is used
Chemical handling and battery charging areas, laboratories, water treatment chemical stores, workshops and remote sites where workers may be exposed to hazardous substances.
Speakman products we list
Ordering Speakman equipment: what we need
Send the model, water supply type, connection size and any tempered water or freeze or heat protection needs. Selection should follow ANSI Z358.1 or the site safety standard.
Facts checked against Speakman's own company timeline (speakman.com), October 2026.
Browse Speakman products by category: Emergency Showers & Eyewash.
FAQ
Questions about the Speakman Eyesaver SEF-1000 Laboratory Faucet with
Answers from our engineering team on installation, compatibility and integration.
01What is special about the Eyesaver SEF-1000?
It is a laboratory faucet with a separate, independently operated emergency eyewash in the same body, fed by two separate water channels.
02What are its flows?
The faucet flows 1.2 gpm (4.54 L/min); the page lists the eyewash at 2.4 gpm at 30 psi in the specification block and 2.0 gpm in the feature list.
03What water temperature is intended for the eyewash?
Tepid water; the sheet recommends a thermostatic mixing valve such as the Speakman STW-370, not included.
04How is the eyewash activated?
By lifting the large handle, which opens the independent eyewash supply to the dual aerated spray heads.
05What should I confirm before ordering?
Confirm the deck hole, the supplies and the tepid water source, then request a quotation with the part number SEF-1000.