Brand:

SMC VQ1100-51 Single Solenoid Valve, 24 VDC, Metal Seal

Description

SMC VQ1100-51 5-port solenoid valve overview

The SMC VQ1100-51 is a 2-position single solenoid valve from the VQ1000 family of plug-in, base mounted five-port valves. It is built with a metal seal spool and is ordered as the valve only: it plugs into a VV5Q11 series manifold base, which supplies the air, the exhaust and the electrical connection for every station. The ordering code reads as follows: VQ is the series, the first digit selects the VQ1000 body size, the next digit sets the actuation, the digit after that selects the seal, the code -5 means a 24 VDC coil, and the blank positions for function, light and surge voltage suppressor and manual override are left empty in the standard model, which gives the standard 0.4 W coil, the built-in light and surge voltage suppressor and the non-locking push type manual override.

In practice the SMC VQ1100-51 is chosen when a machine builder or maintenance team needs a compact valve island that can control double acting cylinders and small grippers from a single manifold. The valve uses a single solenoid with spring return, so the valve returns to its home position when the coil is de-energised. The metal seal construction keeps sliding resistance low, which is why the response time and the minimum operating pressure are better than on the rubber seal version of the same series.

This page summarises the data printed in the manufacturer catalog for the VQ1100-51, so that buyers in Oman and the GCC can check the main limits before sending a request. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Key features of the VQ1100-51

The catalog describes the VQ1000 range as a space-saving, thin and compact design with high flow capacity. For the VQ1100-51 the points that matter most on site are listed below.

  • Plug-in unit construction: the VQ1100-51 is removed and replaced from the top of the manifold without disturbing the piping, using the one-clamp, non-bias structure described in the catalog.
  • Manifold pitch and flow: the VQ1000 manifold pitch is 10.5 mm and the catalog quotes a sonic conductance of 0.70 dm3/(s bar) from the supply side to the cylinder ports for this model.
  • Low power: the standard coil draws 0.4 W on 24 VDC (17 mA), and a high-speed response coil rated 0.95 W is available under a different function code.
  • Manual override: the standard push type override needs a tool, and locking and slide-locking overrides are offered as options on the same family.
  • Wiring choices at manifold level: the VV5Q11 base accepts D-sub, flat ribbon, terminal block, lead wire and serial transmission kits, so the same VQ1100-51 valve can be used in a hard-wired or a fieldbus architecture.
  • Built-in one-touch fittings on the manifold shorten piping time compared with threaded ports.

Because the VQ1100-51 is only the valve, the manifold base, end plates, blanking plates and fittings are ordered with their own part numbers. This keeps stock flexible, since a spare VQ1100-51 fits any free station of the matching base.

VQ1100-51 technical specifications

The table below lists the values that the manufacturer publishes for the VQ1100-51. Flow figures are given for port size C6 without a back pressure check valve, and the response times follow the catalog test method at a supply pressure of 0.5 MPa with clean air and a light and surge suppressor fitted.

Parameter Value
Model VQ1100-51
Series VQ1000
Valve type 2-position single solenoid, 5-port
Seal Metal seal
Fluid Air (clean air; use dry air to prevent condensation at low temperature)
Maximum operating pressure 0.7 MPa
Minimum operating pressure 0.1 MPa
Ambient and fluid temperature minus 10 to 50 degC (no freezing)
Lubrication Not required
Coil rated voltage (code -5) 24 VDC
Allowable voltage fluctuation plus or minus 10 percent
Power consumption, standard coil 0.4 W DC (17 mA)
Sonic conductance, supply to cylinder (1 to 2/4) 0.70 dm3/(s bar), b = 0.15, Cv = 0.16
Sonic conductance, cylinder to exhaust (2/4 to 3/5) 0.72 dm3/(s bar), b = 0.25, Cv = 0.18
Response time, standard 0.4 W coil 15 ms or less
Response time, high-speed 0.95 W coil 12 ms or less
Response time, AC types 29 ms or less
Impact / vibration resistance 150 / 30 m/s2
Enclosure Dust-protected
Valve weight 67 g
Applicable manifold base VV5Q11-series plug-in manifold

Mounting information is as follows. The catalog also lists a high-pressure metal seal type rated to 1.0 MPa, which is selected with a different function code, not with this model. The cylinder ports of a VV5Q11 base come as C3 (3.2 mm), C4 (4 mm), C6 (6 mm) one-touch fittings or M5 thread, and the supply port is C8 (8 mm one-touch fitting). Exhaust can be piped away or released through the optional direct exhaust outlet with built-in silencer. Always read the exact wording in the datasheet when a value drives a safety decision.

Typical applications in Oman and the GCC

A compact manifold valve such as the VQ1100-51 suits equipment where many small actuators sit close together. In Oman and the wider Gulf region that includes packaging and filling lines in food and beverage plants, bottling and palletising machines, assembly stations in light manufacturing, and the automated test and handling rigs found in workshops and fabrication yards.

In oil and gas facilities, pneumatic manifolds of this size are often used inside skid-mounted packages and local control cabinets to drive small process actuators, sample handling cylinders and clamp mechanisms, while larger process valves use heavier solenoids. In water and wastewater works and in utilities, the VQ1100-51 can operate small gates, dosing devices and sampling mechanisms where clean instrument air is available.

Heat and dust are the two conditions that most often limit service life in the region. The VQ1100-51 is rated for ambient and fluid temperatures of minus 10 to 50 degC without freezing and carries a dust-protected enclosure rating, so cabinet ventilation, shading and clean, dry air supply remain the responsibility of the system designer.

Selection and compatibility notes for the VQ1100-51

Start from the actuator. The VQ1100-51 offers 0.72 dm3/(s bar) on the cylinder side exhaust path, so check the cylinder bore and the required speed against the flow data before choosing between VQ1000 and the neighbouring body size. The catalog includes a cylinder speed chart that links valve size, tube size and cylinder bore.

Check the electrical side next. The VQ1100-51 uses a 24 VDC coil, which is the voltage that carries the CE-compliant variants of the family. Other voltages exist in the family, with 12 VDC, 100 VAC, 110 VAC, 200 VAC and 220 VAC listed in the catalog, but they use different part numbers.

The catalog warns that the standard DC specification should be used when a coil is energised continuously for long periods. If a station will stay on for hours, tell us so that the correct coil can be offered. A double solenoid or 3-position valve such as the VQ1100-51 also needs both coils wired and controlled so that they are never driven on together.

  • Base: VV5Q11 plug-in manifold of the VQ1000 family, with F, P, T, L and S wiring kits as described in the catalog.
  • Fluid: air only, filtered and preferably dried; lubrication is not required.
  • Minimum operating pressure for this model: 0.1 MPa; maximum 0.7 MPa for the standard model.
  • Manual override: standard push type needs a tool; other styles are separate options.

Installation and commissioning of the VQ1100-51

Mount the manifold base first, with the supply and exhaust ports piped and the end plates secured. Blanking plates must close any empty stations. Fit the VQ1100-51 on its station and clamp it with the one-clamp fixing, tightening evenly so that the valve sits flat on the base.

Before applying pressure, confirm that the coil voltage on the manifold wiring matches the 24 VDC rating of the VQ1100-51. With the supply raised slowly to the working pressure, operate the manual override on each station to check the direction of motion of the cylinder, then confirm the electrical signal from the controller. If the valve is of the double type, make sure that the last commanded position is the safe one on power-up.

Set cylinder speed with speed controllers, never by throttling the supply to the manifold, and fit silencers or the direct exhaust option where noise matters. Keep tubing runs short and free of sharp bends.

Maintenance and service life

A plug-in valve is easy to maintain because the VQ1100-51 can be swapped without opening the pipework. Keep a spare of the same part number on the shelf for critical lines and replace the unit as a whole if a cylinder is slow, a station leaks air from the exhaust, or the coil indicator no longer responds.

Drain filters and air dryers regularly. Condensate, oil mist and rust particles are the most common causes of sticking spools in hot and humid sites. Check one-touch fittings and tubing for cracks every few months, because ultraviolet light and heat age plastic tubing outdoors.

Do not disassemble the pilot or spool of the VQ1100-51 in the field unless the catalog procedure is followed. Spare pilot parts and port blocks are listed under their own part numbers in the manufacturer documentation.

Related products and ordering notes

Typical items ordered together with the VQ1100-51 are the VV5Q11 manifold base with the chosen station count and kit, blanking plates, individual supply or exhaust spacers, regulator units, silencers and one-touch fittings. When several valves share one base the full manifold can be specified with the part number of every station.

When you send a request, list the VQ1100-51 quantity, the station count of the base, the kit type, the cylinder port code, and whether a different voltage, a manual override style or a made-to-order feature is required. If the VQ1100-51 is only a replacement for an installed valve, send the nameplate details instead so that the exact variant can be matched.

Frequently asked questions about the VQ1100-51

The questions below cover what buyers ask most often about the VQ1100-51: the voltage code, the manifold it fits, the response time and the way it is ordered. Short answers are repeated in the question list that accompanies this page.

Documents and quotation

A datasheet extract covering the VQ1100-51, with the ordering code, the standard specifications and the model table, is attached to this page. To receive a quotation, send the RFQ with the part number VQ1100-51, the quantity, the delivery location and any wiring or manifold requirements, and we will confirm availability and lead time for Oman and the GCC.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

SMC is the Japanese specialist in pneumatic automation: air preparation units, solenoid valves, cylinders, fittings, process valves and sensors. Yoshiyuki Takada founded the company in Tokyo on 27 April 1959 as Shoketsu Kinzoku Kogyo, which means Sintered Metal Corporation, and its first products were sintered metal filters. SMC Corporation is headquartered in Tokyo and listed on the Tokyo Stock Exchange, and its products are used on machines and instrument air lines across the world.

Seven Star LLC, an independent supplier in Oman, lists SMC AW series filter regulators (AW20 and AW40) and the VX2 series direct-operated 2-port solenoid valve, and sources other SMC parts by full part number.

SMC company profile

Founded 27 April 1959, Tokyo, Japan, as Shoketsu Kinzoku Kogyo (Sintered Metal Corporation)
Founder Yoshiyuki Takada (1928–2024)
First products Sintered metal filters; pneumatic air line equipment from 1961
Headquarters Tokyo, Japan
Ownership SMC Corporation, a public company listed on the Tokyo Stock Exchange
Product families AF/AR/AW modular air preparation, VT/VQ/SY solenoid valves, VX/VXZ 2-port valves, air cylinders and rotary actuators, fittings and tubing, pressure and flow switches, vacuum equipment

Milestones

  • 1959: Shoketsu Kinzoku Kogyo is founded in Tokyo on 27 April and starts making sintered metal filters.
  • 1961: Pneumatic air line equipment is added.
  • 1964: Automatic control equipment becomes part of the business.
  • 1967: The first overseas operation starts, with a stake in an Australian company.
  • 1970: SMC begins making air cylinders.

SMC series listed on this page

The AW is a combined filter and pressure regulator in SMC's modular air preparation line. The body size is in the name: AW20 is the smaller unit and AW40 the larger, and the digits after the dash give the port size. A part number such as AW40-04-A therefore describes body size, port and options in one string. The VX2 is a direct-operated two-port solenoid valve for shutting off air, water, oil or steam, depending on the body and seal materials chosen.

SMC products we list

Family Examples
Pneumatic Cylinders CA2B50-100 Tie Rod Air Cylinder 50 mm Bore, CP96SDB63-100C ISO 15552 Cylinder 63 mm Bore, CRQ2BS20-90 Compact Rotary Actuator Size 20, CY1S20-300Z Magnetically Coupled Rodless, CY3B25-300Z Magnetically Coupled Rodless, MB1B40-100Z Square Tube Air Cylinder 40 mm, MGPM40-25Z Compact Guide Cylinder 40 mm Bore, MHC2-16D Angular Air Gripper 16 mm Bore and 6 more
Solenoid Valves SY3120-5LZD-M5 Compact 5-Port Solenoid Valve, SY5120-5LZD-01 5-Port Solenoid Valve SY5000, SY7120-5LZD-02 5-Port Solenoid Valve SY7000, VK3120-5G-M5 Direct Operated 5-Port Solenoid, VQC1101-5 Plug-in 5-Port Solenoid Valve, VQC4101-5 Plug-in 5-Port Solenoid Valve, VT307-5G1-01 3-Port Direct Operated Solenoid, VX2 Series Direct-Operated 2-Port Solenoid and 1 more
Regulators AF30-03 Modular Air Filter 3/8 Rc, AR30-03 Modular Pressure Regulator 3/8 Rc, AW20 Air Filter & Pressure Regulator, AW40 Series Modular Filter Regulator

Ordering SMC parts: what we need

Give the complete SMC part number from the label, including thread prefix, options and the final suffix letter. For AW units state gauge, drain type and bracket if you need them. For VX2 valves send coil voltage, port size, orifice, body and seal material, and the fluid. Buyers in the GCC often have NPT or G threads on site, so say which thread standard the piping uses.

Facts checked against SMC's published corporate history, October 2026.

FAQ

Questions about the SMC VQ1100-51 Single Solenoid Valve, 24 VDC, Metal

Answers from our engineering team on installation, compatibility and integration.

01What does the code -51 mean in VQ1100-51?
In the manufacturer ordering code, -5 stands for a 24 VDC coil, the trailing 1 is a fixed digit of the base mounted plug-in code, and the empty option positions mean the standard light and surge voltage suppressor and the non-locking push type manual override, so VQ1100-51 is a standard 24 VDC valve.
02Which manifold does the VQ1100-51 fit?
The VQ1100-51 is a plug-in valve for the VV5Q11 series manifold base of the VQ1000 family. The base is ordered separately with the station count, the cylinder port size and the wiring kit.
03What is the response time of the VQ1100-51?
The catalog lists 15 ms or less for the standard 0.4 W coil and 12 ms or less for the high-speed 0.95 W coil, measured at 0.5 MPa with clean air and a suppressor fitted.
04What air pressure can the VQ1100-51 use?
Maximum operating pressure for the standard model is 0.7 MPa. The minimum operating pressure for this model is 0.1 MPa, and the ambient and fluid temperature range is minus 10 to 50 degC without freezing.
05How do I request a quotation for the VQ1100-51?
Send an RFQ with the part number VQ1100-51, the quantity and the delivery location. Seven Star LLC will reply with availability and lead time; no price is shown on this page.