ALSTOM 64/07104909/4 Solenoid Valve
Overview:
The ALSTOM 64/07104909/4 Solenoid Valve is a mission-critical electromechanical component engineered for heavy-industrial process control. Designed to handle the rapid switching of pneumatic lines and fluid circuits, this valve acts as the primary interface between electronic control logic and mechanical actuation. In the high-stakes environments of Oman and the wider Middle East, process reliability in power generation and large-scale automation is an absolute necessity. Seven Star LLC supplies the ALSTOM 64/07104909/4 as a specialized replacement and upgrade component for facilities that depend on instantaneous fluid control. By integrating this highly responsive solenoid valve into an automation network, plant operators ensure that safety interlocks, pneumatic actuators, and pilot-operated systems function with microsecond precision.
Operational Logic and Electromagnetic Control
The operational logic of the ALSTOM 64/07104909/4 is based on highly efficient electromagnetism. When the control system (such as a PLC or DCS) sends an electrical current to the valve’s coil, a strong magnetic field is instantly generated. This magnetic force lifts the internal ferromagnetic plunger against a return spring, thereby opening or closing the fluid orifice depending on whether the valve is configured as normally open (NO) or normally closed (NC). This electromagnetic actuation guarantees extremely fast response times, which is critical for emergency shutdown sequences and high-speed pneumatic tooling. When the power is removed, the mechanical spring safely returns the plunger to its resting position. This fail-safe operational logic ensures that industrial pipelines and air circuits behave predictably during sudden power outages.
Engineering Design and Mechanical Resilience
Engineering durability is deeply embedded in the physical construction of the ALSTOM 64/07104909/4. The valve body is machined from high-grade industrial materials—typically hardened brass or stainless steel—to withstand the abrasive and corrosive nature of continuous industrial flows. The internal sealing mechanisms are composed of resilient elastomers that maintain a leak-proof barrier even after hundreds of thousands of switching cycles. Furthermore, the electrical coil is hermetically sealed within a robust epoxy or specialized resin casing, providing a high Ingress Protection (IP) rating against the fine dust, humidity, and chemical vapors frequently encountered in Middle Eastern industrial zones. This enclosed design protects the sensitive copper windings from environmental degradation and electrical short circuits.
Key Features and Technical Advantages
The ALSTOM 64/07104909/4 offers a comprehensive suite of technical advantages tailored for B2B industrial infrastructure. Its primary feature is its continuous duty rating; the coil is designed to remain energized for extended periods without overheating or suffering thermal failure. The valve also supports a wide operating pressure range, making it suitable for both low-pressure instrument air and high-pressure fluid transfer lines. Its compact physical footprint allows it to be easily integrated into crowded pneumatic manifolds and tight control cabinets. Additionally, the ALSTOM Solenoid Valve features high resistance to mechanical vibration, a crucial advantage when mounted directly onto large compressors, turbines, or heavy moving machinery where resonant frequencies often destroy commercial-grade valves.
Industrial Applications across the Middle East
Seven Star LLC facilitates the supply of the ALSTOM 64/07104909/4 for several critical industrial sectors across the region:
-
Power Generation Facilities: Controlling pneumatic actuators for turbine bypass systems and boiler feed processes in large-scale power plants.
-
Oil and Gas Automation: Managing instrument air for safety shutdown valves and directional flow control in refineries.
-
Heavy Manufacturing: Regulating compressed air in automated assembly lines, robotic welding stations, and material handling systems.
-
Water and Wastewater: Acting as pilot valves for larger hydraulic gate valves in municipal water treatment facilities in Oman.
-
Railway and Transportation: Serving in pneumatic braking and suspension leveling systems where ALSTOM’s legacy of transport engineering is prominent.
Technical Specifications Table
| Specification | Technical Data |
| Model Number | 64/07104909/4 |
| Manufacturer | ALSTOM |
| Component Type | Electromechanical Solenoid Valve |
| Actuation Method | Electromagnetic (Direct / Pilot Operated) |
| Fluid Compatibility | Compressed Air, Inert Gases, Light Industrial Fluids |
| Coil Duty Rating | Continuous Duty Rated |
| Body Material | Industrial Grade Brass / Stainless Steel |
| Protection Class | IP65 / NEMA 4 (Dust and Water Resistant) |
| Operating Temperature | -20°C to +80°C (Typical Industrial Range) |
| Connection Standard | Standard Industrial Threaded / Flanged |
Request a Quote for ALSTOM 64/07104909/4 Solenoid Valve
Seven Star LLC is a reliable supplier of industrial automation and pneumatic control components in Oman and the GCC. For a formal B2B quotation, technical support, or to request the official datasheet for the ALSTOM 64/07104909/4 Solenoid Valve, contact our engineering sales department today.
Identifying the Valve Before Ordering
ALSTOM part numbers such as 64/07104909/4 are typically plant or equipment references, and the valve itself may carry a separate manufacturer marking on the body or coil. To avoid a mismatch, collect the following from the installed valve before ordering:
- the complete ALSTOM reference and any equipment tag or drawing number where the valve appears;
- all markings on the valve body and coil, including coil voltage (AC or DC), power and connector type;
- port size, thread type and the number of ports, which shows whether it is a 2-way or 3-way valve;
- whether the valve is normally open or normally closed in its current duty;
- the medium and working pressure of the circuit.
Clear photos of the nameplate, coil label and pipe connections normally allow the valve to be confirmed.
Installation and Commissioning
- Isolate and vent the circuit under permit; on turbine or safety systems, coordinate with operations before removing the valve.
- Flush lines and fit the new valve with the flow direction arrow correct; instrument air should be clean and dry.
- Confirm coil voltage at the terminals and make sure cable glands and connectors are sealed to keep out dust and moisture.
- Function-test the valve with the associated actuator or interlock and confirm the fail position on loss of power.
Maintenance and Troubleshooting
Most solenoid valve problems come from the supply side. Wet or dirty instrument air causes sticking plungers and leaking seats, so check filters and dryers when valves begin to fail. If the valve does not change over, check that voltage reaches the coil, then measure coil resistance. A humming AC coil often means dirt preventing the plunger from seating fully. Where seats or seals have worn, replacing the complete valve is usually faster than rebuilding it in the field.
Applications in Oman and the GCC
ALSTOM equipment is installed in power generation and industrial plants across the region, and legacy turbine and auxiliary systems often rely on original-reference spare parts. Holding identified spare solenoid valves for critical actuators and trip circuits reduces the risk of long outages while a replacement is sourced.
Sourcing Through Seven Star LLC
Send us the part reference, photos of the valve and the equipment it serves. Our team will work to identify the valve, confirm a suitable original or equivalent option with you, and provide availability and lead time.
Related Products
ALSTOM solenoid valve 64/07104909/4
One item is listed: a solenoid valve under ALSTOM part number 64/07104909/4. The number is a spare parts reference, not a catalog type code, so it does not tell an outsider the port size, coil voltage or body material. Those details come from the spare parts list of the machine or from the label of the valve itself. This page therefore gives no technical figures for it.Ordering ALSTOM spare parts: what we need
Send the complete part number exactly as written, including the slashes. Add a photo of the valve and of any maker's label on the coil or body, since solenoid valves on larger machines often carry the valve manufacturer's own type code. Tell us the equipment the valve belongs to, the serial number of that equipment, and the coil voltage and medium if you know them.Browse ALSTOM products by category: Solenoid Valve.

Reviews
There are no reviews yet.