Schneider Electric R9F12110 Resi9 1P 10 A C-curve MCB
Description
R9F12110: Resi9 1P 10 A C-curve miniature circuit breaker
The R9F12110 is a Schneider Electric Resi9 miniature circuit breaker (single-pole, 10 A, C curve) with thermal-magnetic tripping and a 6000 A breaking capacity at 230 V AC. It clips onto a DIN rail, carries ON/OFF indication on the toggle and is finished in white (RAL 9003), the colour that distinguishes the Resi9 range from the grey Easy9 range. Seven Star LLC supplies the R9F12110 in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference: across the references in this lane the digit after R9F12 follows the pole count and the last two digits follow the rated current, so R9F12110 reads as 1P and 10 A. This is our reading of the pattern and the product title, not a published ordering table, so always confirm the full reference. With one protected pole it breaks the phase conductor only and is intended for a single-phase branch where the neutral runs separately. The datasheet quotes 230 V AC as the operating voltage.
Durability and environment for the R9F12110
The Resi9 datasheet lists 20000 cycles mechanical and 10000 cycles electrical operating cycles, which are higher than the 10000 and 4000 cycles that the Easy9 datasheets in the same lane quote. For a board that is switched often, for example circuits that are isolated at every maintenance visit, that margin is worth noting. Protection is IP20, pollution degree 2 and tropicalisation level 2.
Operating ambient is -25 to 60 °C and storage -40 to 60 °C, with humidity up to 95 % at 55 °C. In a Gulf building, enclosure temperature can be much higher than room temperature, and a breaker carrying its full rating in a closed board will run hotter than one lightly loaded, so allow for derating margin and ventilation. This unit itself is not a weatherproof device; the enclosure must keep dust and water away.
Technical specifications of the R9F12110
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / R9F12110 |
| Range / product name | Resi9 / Resi9 MCB |
| Product type | Miniature circuit-breaker |
| Device application | Protection |
| Poles / protected poles | 1P / 1 |
| Rated current [In] | 10 A |
| Network type / frequency | AC / 50/60 Hz |
| Trip unit | Thermal-magnetic |
| Curve code | C |
| Magnetic tripping limit | 5–10 × In (calculated 50–100 A) |
| Rated operational voltage [Ue] | 230 V AC |
| Breaking capacity | 6000 A Icn at 230 V AC 50/60 Hz |
| Limitation class | 3 |
| Rated insulation voltage [Ui] | 440 V AC |
| Rated impulse withstand [Uimp] | 4 kV |
| Overvoltage category | III |
| Control / signalling | Toggle; ON/OFF indication |
| Mounting | Clip-on, DIN rail |
| Width | 18 mm (2 × 9 mm pitches) |
| Height / depth / embedding depth | 81 mm / 72 mm / 44 mm |
| Net weight | 120 g |
| Colour | White (RAL 9003) |
| Terminals | 1–25 mm² – rigid; 1–16 mm² – flexible with ferrule; 1–16 mm² – flexible |
| Wire stripping length | 14 mm |
| Tightening torque | 2 N.m |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Standard | EN/IEC 60898-1 |
| Quality label | EAC |
| Degree of protection | IP20 |
| Pollution degree / tropicalisation | 2 / 2 (IEC 60068-1) |
| Ambient temperature | Operation -25 to 60 °C; storage -40 to 60 °C |
| Relative humidity | 95 % at 55 °C |
| Packing | 1 piece, 92 g; carton of 12 |
| Warranty | 18 months |
Typical uses of the R9F12110 in Oman and the GCC
Resi9 is aimed at residential and small commercial boards, so this unit is most often specified for shop fit-outs and retail units, warehouse lighting and socket groups and site offices and camp accommodation. Long summer peaks mean cooling circuits run near their rating for months, which makes the choice of 10 A and the board ventilation more important than in cooler climates. Dust and humidity near the coast reinforce the need for a closed, well-sealed enclosure because the breaker body is IP20.
Where the R9F12110 sits among Resi9 references
The table compares nearby Resi9 C-curve references with the same 6000 A class. Pole count drives width and voltage, while the amp rating changes the magnetic trip band and sometimes the terminal size.
| Part number | Poles | Rated current | Width | Rated voltage | Net weight |
|---|---|---|---|---|---|
| R9F12106 | 1P | 6 A | 18 mm | 230 V AC | 120 g |
| R9F12110 (this page) | 1P | 10 A | 18 mm | 230 V AC | 120 g |
| R9F12116 | 1P | 16 A | 18 mm | 230 V AC | 120 g |
| R9F12120 | 1P | 20 A | 18 mm | 230 V AC | 120 g |
| R9F12125 | 1P | 25 A | 18 mm | 230 V AC | 120 g |
| R9F12132 | 1P | 32 A | 18 mm | 230 V AC | 120 g |
| R9F12140 | 1P | 40 A | 18 mm | 230 V AC | 120 g |
Installation and upkeep of the R9F12110
De-energise and prove dead, then clip the R9F12110 onto the rail and check that the toggle moves freely. Insert stripped conductors fully, tighten to 2 N.m with a calibrated driver, and fit ferrules where the datasheet lists flexible cable with ferrule. After switching on, confirm that the ON/OFF indication matches the toggle position and label the circuit.
Re-torque terminals during scheduled inspections, especially in boards that are warm or that carry vibration, and look for discoloured plastic that signals heat at a termination. If a breaker trips on a short circuit, find the cause before resetting; if it trips repeatedly on a normal load, the rating or the load is wrong rather than the device.
Dimensions, terminals and wiring of the R9F12110
The R9F12110 measures 18 mm wide by 81 mm high and 72 mm deep, with an embedding depth of 44 mm, and weighs 120 g net. That is 2 modules of 9 mm, so it occupies 1 standard pole width of 18 mm on the rail. Terminals are tunnel type at the top and bottom and accept 1–25 mm² – rigid; 1–16 mm² – flexible with ferrule; 1–16 mm² – flexible. Strip conductors to 14 mm and tighten to 2 N.m.
At 18 mm this is the slimmest device in the lane, the choice when many single-phase circuits have to share one small consumer unit.
Information to send with an RFQ for the R9F12110
- Exact reference R9F12110 and the quantity needed.
- Supply voltage, system type and earthing arrangement.
- Prospective short-circuit current at the board, if known.
- Load description and cable size for the circuit.
- Other poles or ratings needed in the same order.
- Delivery location and timeline.
Before ordering, also check that the board enclosure, busbar arrangement and neighbouring breakers leave enough spacing for heat to dissipate, since crowded boards in hot rooms run closer to their limits than the rated ambient suggests.
Keep a record of the installed ratings on the board schedule and note the supply voltage at commissioning, because later extensions and fault investigations depend on knowing exactly what protects each circuit and what the upstream device allows through.
Spare breakers and matching ratings are worth planning for sites that run continuously, since a replacement of the same rating, pole count and curve keeps the original protection design intact when a unit has to be changed after a trip or a fault.
If the board will be extended later, leave spare rail length and consider how added circuits will change the total load and heat inside the enclosure, which affects how close each breaker will run to its rating in summer.
Documents and quotation
The manufacturer datasheet for the R9F12110 is attached on this page and holds the full specification summarised above.
Send us the reference R9F12110, quantity and delivery location and Seven Star LLC will reply to your request. We supply as an independent supplier based in Muscat.
Other Models in the Se Resi9 Mcb C Range
Seven Star LLC supplies models from the Se Resi9 Mcb C range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric R9F12106 Resi9 1P 6 A C-curve MCB | Circuit Breakers | View details |
| Schneider Electric R9F12110 Resi9 1P 10 A C-curve MCB | Circuit Breakers | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric R9F12110 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric R9F12110 Resi9 1P 10 A C-curve
Answers from our engineering team on installation, compatibility and integration.
01What is the rating of the R9F12110?
The datasheet lists 10 A rated current, 1P, C curve, thermal-magnetic trip unit, with 6000 A Icn at 230 V AC 50/60 Hz.
02What is the magnetic trip range of the R9F12110?
The magnetic tripping limit is 5 to 10 times In, about 50 to 100 A for a 10 A device. This is calculated from the datasheet value.
03What size is the R9F12110 and how is it mounted?
It is 18 mm wide, 81 mm high and 72 mm deep (2 modules of 9 mm) and clips onto a DIN rail.
04What conductors fit the R9F12110 terminals?
Tunnel type terminals, top or bottom: 1-25 mm2 - rigid; 1-16 mm2 - flexible with ferrule; 1-16 mm2 - flexible. Strip 14 mm and tighten to 2 N.m.
05What durability and standard are listed for the R9F12110?
The datasheet lists 20000 cycles mechanical and 10000 cycles electrical cycles, standard EN/IEC 60898-1, limitation class 3, IP20 and an 18-month warranty.