Schneider Electric LV430631 ComPact NSX160F 125 A Circuit
Description
LV430631 a 125 A ComPact NSX160F thermal-magnetic breaker
The LV430631 is a Schneider Electric product listed in the datasheet as: Circuit breaker, ComPact NSX160F, 36kA/415VAC, TMD trip unit 125A, 3 poles 3d. The LV430631 is a ComPact NSX160F with a 125 A TM-D thermal-magnetic trip unit, three poles and 36 kA breaking capacity at 415 V. The frame is larger than the current, so there is room for growth if the trip unit is later changed within the same frame. Seven Star LLC supplies the LV430631 in Oman and the GCC as an independent supplier based in Muscat.
Decoding the reference: NSX160F is the 160 A frame with performance level F, TMD indicates the thermal-magnetic trip unit, and 125 A is the trip rating at 40 degrees Celsius. This differs from the 250 A unit LV431630, which sits on the 250 A frame.
Technical specifications of the LV430631
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / LV430631 |
| Description | Circuit breaker, ComPact NSX160F, 36kA/415VAC, TMD trip unit 125A, 3 poles 3d |
| Range | ComPact |
| Product name | ComPact NSX |
| Range of Product | ComPact NSX100 to 250 |
| Device short name | NSX160F |
| Product or Component Type | Circuit breaker |
| Device Application | Distribution |
| Number of poles | 3P |
| Protected poles description | 3t |
| Line Rated Current | 125 A 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network Frequency | 50/60 Hz |
| Suitability for isolation | Yes EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit | 10 kA 600 V AC 50/60 Hz UL 508 |
| breaking capacity | 36 kA 380/415 V AC 50/60 Hz IEC 60947-2; 85 kA 220/240 V AC 50/60 Hz IEC 60947-2; 22 kA 525 V AC 50/60 Hz IEC 60947-2 |
| Performance level | F 36 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control Type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
| [Uimp] rated impulse withstand | 8 kV |
| [Ics] rated service short-circuit | 35 kA 440 V AC 50/60 Hz IEC 60947-2 |
| Mechanical durability | 40000 cycles |
| Electrical durability | 7500 cycles 690 V In; 15000 cycles 690 V In/2; 20000 cycles 440 V In; 40000 cycles 440 V In/2 |
| Mounting Support | Backplate |
| Upside connection | Front |
| Downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (thermal); I : for short-circuit protection (magnetic) |
| Trip unit rating | 125 A 40 °C |
| Long-time pick-up adjustment | Adjustable |
| [Ir] long-time protection pick-up | 0.7 to 1 x In |
| Long-time protection delay | Fixed |
| [tr] long-time protection delay | 120 to 400 s 1.5 x In |
| adjustment range | 15 s 6 x Ir |
| Short-time protection pick-up | Fixed |
| [Isd] Short-time protection pick- | 1250 A |
Ratings and endurance of the LV430631
Network frequency: 50/60 Hz. Rated operational voltage: 690 V AC 50/60 Hz. Utilisation categories: Category A. Trip unit technology: Thermal-magnetic. Breaking capacity: 36 kA 380/415 V AC 50/60 Hz IEC 60947-2; 85 kA 220/240 V AC 50/60 Hz IEC 60947-2; 22 kA 525 V AC 50/60 Hz IEC 60947-2. Mechanical durability: 40000 cycles. Electrical durability: 7500 cycles 690 V In; 15000 cycles 690 V In/2; 20000 cycles 440 V In; 40000 cycles 440 V In/2.
Voltage ratings are the same as the larger frame: 690 V AC operational, 800 V insulation and 8 kV impulse, with 36 kA at 380/415 V and 85 kA at 220/240 V. Where the datasheet lists a UL value it is 10 kA at 600 V AC, which is different from the IEC figure, so use the correct standard for the project.
Endurance is better than the 250 A unit: mechanical durability is 40000 cycles and electrical durability is 7500 cycles at 690 V In, with higher values at lower voltages. That suits feeders that are switched regularly.
Selecting between 125 A and 250 A NSX breakers
The two references use identical TM-D logic. The main differences are the frame size, the number of operations, and the available trip unit currents. If a board is designed around 125 A feeders, the LV430631 saves cost and space compared with the LV431630.
For motor circuits the NSX with thermal-magnetic protection is not the best match; a magnetic-only or electronic trip unit is typical. This breaker is meant for cables and distribution.
The datasheet downloaded for this page carries lifecycle notices: Discontinued on: Jun 15, 2023. For a plant that already runs this reference that makes the LV430631 a spare-and-replacement item, and it is worth fixing the stock level and the long-term successor plan at the same time. We can discuss compatible alternatives once we know the installation.
Selection checklist for the LV430631
- Rating: 125 A at 40 degrees Celsius.
- Frame: NSX160, three poles protected.
- Breaking: 36 kA at 415 V, F level.
- Trip: TM-D, long-time 0.7 to 1 x In.
- Connection: front, 35 mm pitch, backplate fixing.
- Lifecycle: discontinued; confirm whether an identical spare is required.
Maintenance of the LV430631
Retorque terminals after the first weeks of operation, because cable relaxation can raise contact temperature. A thermal camera survey of the board identifies loose connections before they cause a trip.
Keep a label with the breaker rating and the protected circuit. When the breaker has interrupted a fault, inspect it per the manual and replace if the contacts or case are damaged.
Typical applications of the LV430631 in Oman and the GCC
In Oman and the GCC, the 125 A rating is common on sub-distribution feeders, air handling units, pump panels and workshop supplies. Because many boards are 10 to 20 years old, the NSX is often replaced like for like to avoid redesigning the busbar.
Dimensions, environment and approvals of the LV430631
For the LV430631, plan the mounting space from the datasheet: 105 mm (W) x 161 mm (H) x 86 mm (D). The LV430631 weighs 2.2 kg. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.
Ambient temperature limits in the datasheet: -50 to 85 °C. Relative humidity: 0 to 95 %. Ingress protection: IP40 conforming to IEC 60529. Operating altitude: 0 to 2000 m without derating; 2000 m–5000 m with derating. Standards listed: EN/IEC 60947. Certifications listed for this reference: CCC; EAC; Marine.
Information to send with an RFQ for the LV430631
- Full reference and quantity required
- Existing equipment, panel or rack it must fit
- Supply voltage, load or signal details of the application
- Required delivery location and timing
- Whether a spare, a replacement or a new installation
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.
Other Models in the Se Nsx Range
Seven Star LLC supplies models from the Se Nsx range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric LV429630 ComPact NSX100F 100 A 36 kA Breaker | Circuit Breakers | View details |
| Schneider Electric LV430630 ComPact NSX160F 160 A 36 kA Breaker | Circuit Breakers | View details |
| Schneider Electric LV431630 ComPact NSX250F 250 A Circuit | Circuit Breakers | View details |
| Schneider Electric LV430631 ComPact NSX160F 125 A Circuit | Circuit Breakers | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric LV430631 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric LV430631 ComPact NSX160F 125 A
Answers from our engineering team on installation, compatibility and integration.
01What rated current does the LV430631 have?
The datasheet gives 125 A 40 °C.
02What is the mechanical durability of the LV430631?
The datasheet gives 40000 cycles.
03What insulation voltage does the LV430631 list?
The datasheet gives 800 V AC 50/60 Hz.
04What trip technology does the LV430631 use?
The datasheet gives Thermal-magnetic.
05What is the net weight of the LV430631?
The datasheet gives 2.2 kg.