Schneider Electric Acti9 iC60H Miniature Circuit Breaker

Description

Overview

The Schneider Electric Acti9 iC60H is a DIN-rail mounted miniature circuit breaker (MCB) that extends the Acti9 iC60 platform to higher fault levels, offering a rated breaking capacity of 10kA across its B, C, and D curve variants up to 63A. Mechanically and dimensionally identical to the standard iC60N, the iC60H is specified wherever a short-circuit study shows prospective fault current at the final-distribution level exceeding the 6kA capacity of a standard-duty MCB, without requiring a change in panel layout or DIN-rail spacing. Compliant with IEC/EN 60898-1 and IEC/EN 60947-2, the iC60H is a common upgrade specification for distribution boards fed from larger transformers or located close to the main incomer, where prospective fault current is inherently higher.

Working closely with plant engineers in the region, Seven Star LLC proudly supplies the Schneider Electric Acti9 iC60H to electrical contractors, panel builders, and consulting engineers throughout the Sultanate of Oman and the wider GCC. Facilities in Muscat, Sohar, and Salalah requiring a formally documented 10kA breaking capacity for compliance with a short-circuit study can source genuine iC60H stock from Seven Star LLC, with full manufacturer test certificates and local technical support.

Operating Principle of the Schneider Electric Acti9 iC60H

The Schneider Electric Acti9 iC60H uses the same combined thermal-magnetic tripping principle as the rest of the iC60 family: a bimetallic thermal element trips on sustained overload current with an inverse-time characteristic, while a magnetic element trips near-instantaneously on the rapid current rise of a short circuit. The distinction of the H-duty variant lies in its internal contact and arc-quenching chamber design, engineered with a higher-rated arc chute and contact system to safely interrupt fault currents up to 10kA without contact welding or case rupture — a meaningful margin over the 6kA capacity typical of a standard-duty MCB in the same physical footprint.

Because the higher breaking capacity is achieved without increasing the physical envelope of the device, the iC60H can be substituted directly for an iC60N on the same DIN rail and busbar comb system wherever a fault-level review determines the additional interrupting margin is required, without redesigning the distribution board. As with the rest of the range, the iC60H is a self-contained electromechanical device requiring no external power, with a red mechanical trip indicator and trip-free operating mechanism that prevents the breaker from being held closed against a persistent fault.

Engineering Design of the Schneider Electric Acti9 iC60H

The Schneider Electric Acti9 iC60H retains the compact modular Acti9 case, with each pole occupying approximately 18mm of standard 35mm DIN-rail width, and is available in 1, 2, 3, and 4-pole configurations to match single-phase and three-phase final circuits. Screw terminals are sized for typical final-circuit cable cross-sections, and IP20-rated terminal shrouding protects against accidental contact once the breaker is installed behind a panel fascia. The toggle handle provides the same clear ON/OFF/tripped indication as the rest of the Acti9 family, and the device snaps directly onto standard DIN rail alongside busbar comb systems for fast multi-way panel assembly.

Because the iC60H shares its mounting footprint, terminal layout, and accessory compatibility with the iC60N and the rest of the Acti9 modular range — including RCDs, isolators, and surge protection devices — panel builders can mix standard and high-breaking-capacity MCBs within the same board without introducing additional part families, simplifying both design and future maintenance stock.

Key Features

The Schneider Electric Acti9 iC60H delivers extra fault-current margin without compromising the space efficiency of the standard Acti9 platform. Its principal characteristics include:

  • Rated breaking capacity of 10kA, roughly 65% higher than the standard-duty iC60N in the same case size.
  • Current ratings up to 63A, available in B, C, and D tripping curves for resistive, general, and inductive/inrush loads.
  • 1, 2, 3, and 4-pole configurations for single-phase and three-phase circuit protection.
  • Mechanically and dimensionally interchangeable with the iC60N, requiring no panel redesign to upgrade fault-current rating.
  • Compact 18mm-per-pole modular design compatible with standard 35mm DIN rail and busbar comb systems.
  • Red mechanical trip indicator and trip-free operating mechanism for clear fault status and safe manual operation.
  • IP20-rated terminal protection against accidental contact behind the panel fascia.
  • Compliant with IEC/EN 60898-1 and IEC/EN 60947-2, supported by full manufacturer test documentation.

Industrial Applications

The Schneider Electric Acti9 iC60H is specified wherever a short-circuit study identifies prospective fault current at the final-distribution level above the 6kA capacity of a standard MCB: sub-distribution boards close to a main incomer, panels fed from higher-capacity transformers, and industrial facilities with dense parallel motor loads. In Muscat’s commercial towers, Oman’s district cooling plants, and light industrial facilities across the Sohar and Salalah economic zones, the iC60H is the standard upgrade path when a consulting engineer’s fault-level calculation calls for additional interrupting margin at the final-circuit level.

With fast quotation turnaround and technical support, Seven Star LLC distributes the iC60H to electrical contractors and panel builders across Oman and the GCC who need documented 10kA breaking capacity to satisfy project specifications and consulting engineer sign-off. Manufacturer test certification documents are available on request to support fault-level compliance requirements on active site programs.

Technical Specifications

The table below summarizes the key technical parameters of the Schneider Electric Acti9 iC60H for specification and procurement purposes.

Parameter Specification
Model Acti9 iC60H
Rated Current Range 1A – 63A
Tripping Curves B, C, D
Poles 1P, 2P, 3P, 4P
Breaking Capacity 10kA (IEC/EN 60898-1 / 60947-2)
Mounting 35mm DIN rail, 18mm per pole
Terminal Protection IP20
Indication Red mechanical trip indicator
Standards IEC/EN 60898-1, IEC/EN 60947-2

Also available: Schneider Electric Prisma iPM Modular Switchboard

Request a Quote for Schneider Electric Acti9 iC60H Miniature Circuit Breaker

Seven Star LLC supports formal RFQ submissions, technical datasheet requests, and availability and lead-time checks for the Schneider Electric Acti9 iC60H across Oman and the GCC. With engineering support in Muscat, our low-voltage distribution division can advise on breaking-capacity selection and coordinated Acti9 board design for your project. Contact Seven Star LLC today to request a formal quotation, download the technical datasheet, or speak with our engineering team about sourcing the iC60H for your next fault-level-critical panelboard build in Muscat, Sohar, Salalah, or anywhere across the Sultanate of Oman.

Other Models in the Schneider Electric Acti9 Modular Devices Range

Seven Star LLC supplies models from the Schneider Electric Acti9 Modular Devices range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric Acti9 iC60N Miniature Circuit BreakerCircuit BreakersView details
Schneider Electric Acti9 iC60H Miniature Circuit BreakerCircuit BreakersYou are viewing this model
Schneider Electric Acti9 C120N MCB 80-125A Main IncomerCircuit BreakersView details
Schneider Electric Acti9 Vigi iC60 RCD Add-On ModuleCircuit BreakersView details
Schneider Electric Acti9 iSW Modular Switch DisconnectorCircuit BreakersView details
Schneider Electric Acti9 iATL Automatic Transfer SwitchCircuit BreakersView details
Schneider Electric Acti9 Smartlink Energy Management ModuleMetering SystemsView details
Schneider Electric Acti9 Active Communicating Circuit Breaker SystemCircuit BreakersView details

Related Products

Datasheets & Documents
  • PDF Datasheet Schneider Electric Acti9 iC60H Miniature Circuit Breaker Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand
Circuit breakers make up the largest part of our Schneider Electric listing, from Acti9 modular devices through ComPacT NSX molded case breakers to MasterPact air circuit breakers. Schneider Electric, which dates from 1836 and is headquartered in Rueil-Malmaison, France, is equally established in drives, PLCs and power metering. Seven Star LLC is an independent supplier of Schneider Electric circuit breakers, Altivar drives, Modicon I/O, power meters, soft starters and dry-type transformers to panel builders and plants in Oman and the GCC.

Schneider Electric product families on this page

Low voltage protection covers Acti9 miniature breakers and their communicating system, ComPacT NSX and PowerPacT H-frame molded case breakers and MasterPact NW air circuit breakers. Altivar 320 variable speed drives appear in several ratings, for example the ATV320U22N4C at 2.2 kW and the ATV320U75N4B at 7.5 kW. Automation is represented by Modicon TM3 expansion modules such as the TM3TM thermocouple input module. Metering includes the EasyLogic PM2000 power meter and iEM2000 modular energy meters. Trihal cast resin transformers and Spacial enclosure accessories complete the electrical distribution side.

Where Schneider Electric equipment is used

Main and distribution switchboards in buildings, utilities and industrial plants carry the breakers and meters. Altivar drives run pumps, fans, conveyors and packaging machines. Modicon controllers with TM3 I/O are common in machine builders' panels, and Trihal transformers serve indoor substations where a dry-type unit is specified.

Ordering Schneider Electric parts: what we need

The commercial reference printed on the product or its carton is the fastest route. For breakers without a reference send rated current, breaking capacity, number of poles, trip unit type, fixed or drawout construction and the accessories fitted, such as shunt trip, auxiliary contacts or motor mechanism. For drives give motor power, supply voltage and the communication option. For transformers send rated power, primary and secondary voltage, vector group and enclosure rating.

Frequently Asked Questions

How does the Schneider Electric Acti9 iC60H differ from the iC60N?
The iC60H offers a higher rated breaking capacity of 10kA compared with the 6kA typical of the standard-duty iC60N, while remaining mechanically and dimensionally interchangeable within the same Acti9 panel layout.
When should the iC60H be specified instead of a standard MCB?
The iC60H should be specified when a short-circuit or fault-level study shows prospective fault current at the final-distribution level exceeds the capacity of a standard-duty MCB, such as boards close to a main incomer or fed by larger transformers.
What tripping curves are available for the iC60H?
The iC60H is available in B, C, and D tripping curves across ratings up to 63A, allowing the correct curve to be matched to resistive, general, or high-inrush inductive loads.
Can the iC60H be mixed with standard Acti9 devices in the same board?
Yes, the iC60H shares its modular footprint, DIN-rail mounting, and terminal layout with the wider Acti9 range, allowing standard and high-breaking-capacity MCBs to be combined within the same distribution board.
Is Seven Star LLC an experienced supply partner for Schneider Electric products?
Yes, Seven Star LLC is an experienced supply partner for Schneider Electric in Oman and the GCC, supplying genuine Acti9 products with full manufacturer test certification and local technical support.