Schneider Electric LC1D50AF7 50 A TeSys Deca Contactor

Description

LC1D50AF7: 50 A TeSys Deca contactor with 110 V AC coil

The LC1D50AF7 is a Schneider Electric TeSys Deca contactor that the datasheet describes as TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 50 A – 110 V AC 50/60 Hz coil. The 50 A reference uses the same 122 x 55 x 120 mm housing as the 40 A and 65 A versions, with a net weight of 0.855 kg, and is rated 50 A in AC-3 and 80 A in AC-1. Seven Star LLC supplies the LC1D50AF7 in Oman and the GCC as an independent supplier based in Muscat.

Reading the reference: LC1D is the TeSys Deca three-pole contactor family, the figure 50 is the frame and current class, and the final letters F7 point to the coil. The datasheet confirms the coil as 110 V AC 50/60 Hz, so no further ordering table is needed to see what is fitted.

Rated at 22 kW at 380/400 V, it is the mid-point of the three medium-frame ratings. Its AC-1 rating of 80 A equals that of the 65 A reference, so for pure resistive duty the choice between them is a matter of availability rather than capability.

Technical specifications of the LC1D50AF7

Parameter Specification
Manufacturer / part number Schneider Electric / LC1D50AF7
Description TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 50 A – 110 V AC 50/60 Hz coil
Range TeSys Deca Advanced
Device short name LC1D
Poles / contact composition 3P / 3 NO
Contactor application Motor control; Resistive load
Utilisation categories AC-3; AC-3e; AC-1; AC-4
Rated operational voltage Power circuit: <= 690 V AC 25 to 400 Hz; Power circuit: <= 300 V DC
Rated operational current AC-3 (≤440 V) 50 A (below 60 °C)
Rated operational current AC-1 80 A at up to 440 V AC (below 60 °C)
Control circuit voltage 110 V AC 50/60 Hz
Rated breaking capacity 900 A at 440 V for power circuit
Associated gG fuse, coordination type 1 / type 2 100 A / 100 A
Rated insulation voltage Ui / impulse Uimp 690 V / 6 kV
Mechanical durability 6 Mcycles
Electrical durability 1.45 million cycles at 50 A in AC-3 and 1.1 million cycles at 80 A in AC-1 (Ue up to 440 V)
Coil technology Without built-in suppressor module
Inrush / hold-in power (50 Hz) 160 VA / 15 VA
Operating time 4 to 19 ms opening; 12 to 26 ms closing
Auxiliary contacts 1 NO + 1 NC
Mounting Rail; Plate
Ingress protection IP20 front face conforming to IEC 60529
Ambient temperature around the device -40 to 60 °C
Dimensions H x W x D 122 mm x 55 mm x 120 mm
Net weight 0.855 kg
Certifications listed CCC; UL; CB Scheme; CSA; CE; UKCA; Marine; EAC

Motor ratings of the LC1D50AF7 at each supply voltage

Supply voltage (AC, 50/60 Hz) Motor power in AC-3 (kW)
220/230 V 15 kW
380/400 V 22 kW
415 V 25 kW
440 V 30 kW
500 V 30 kW
660/690 V 33 kW

AC-3 is the category for squirrel-cage motors started and stopped while running; the datasheet converts the 50 A rating into the motor powers above for each supply voltage. At 380/400 V the LC1D50AF7 is listed for 22 kW. For heavier duty such as inching or plugging the AC-4 category applies and the datasheet lists 11 kW at 400 V, which is lower because those duties wear the contacts faster. The same device is rated 80 A in AC-1, the category for resistive loads such as heaters, so it can switch a higher current when the load is not a motor.

Coil and control supply of the LC1D50AF7

The coil of the LC1D50AF7 is rated 110 V AC at 50/60 Hz. That fits machine-control circuits fed from a 110 V transformer, a voltage seen on equipment built to some other markets; a lower coil current than 24 V and a lower hazard to maintenance staff than line voltage.

According to the datasheet the contactor operates between 0.8 and 1.1 times Uc at 50 Hz, which for this coil is about 88 V to 121 V, and between 0.85 and 1.1 times Uc at 60 Hz (93.5 V to 121 V). Drop-out occurs between 0.3 and 0.6 times Uc, about 33 V to 66 V, which is the range to remember when a weak control supply makes the contactor chatter instead of opening cleanly.

Inrush is 160 VA at 50 Hz (140 VA at 60 Hz) and hold-in is 15 VA (13 VA at 60 Hz). Dividing by the coil voltage gives roughly 1.45 A on closing and 0.14 A when held; these are calculated approximations for sizing the control transformer or PLC interposing relay, not datasheet figures. The datasheet gives closing in 12 to 26 ms and opening in 4 to 19 ms.

The coil is described as without built-in suppressor module, so inductive switching of the coil can disturb sensitive electronics on the same control circuit unless a suppressor is added separately; check accessory compatibility with the supplier before ordering one.

Protection, coordination and service life of the LC1D50AF7

For short-circuit protection the datasheet pairs the LC1D50AF7 with a 100 A gG fuse at up to 690 V for coordination type 1 and 100 A gG for type 2. Type 2 is the stricter level: the contactor must remain usable after a fault, with at most light welds that can be separated. The rated breaking capacity is 900 A at 440 V for power circuit and the short-time withstand current is listed as 400 A 40 °C – 10 s for the power circuit.

Contact life is stated as 6 Mcycles mechanically and, electrically, 1.45 million cycles at 50 A in AC-3 and 1.1 million cycles at 80 A in AC-1 (Ue up to 440 V). The maximum operating rate is 3600 cyc/h at 60 °C. For functional-safety calculations the datasheet gives a B10d of 1,369,863 cycles at nominal load and 20,000,000 cycles at mechanical load, per EN/ISO 13849-1.

The auxiliary block built into the LC1D50AF7 is 1 NO + 1 NC; the datasheet notes the contacts are mechanically linked and that the NC is a mirror contact to IEC 60947-4-1, so it can be used in a safety circuit to prove that the main contacts have opened. The signalling circuit is specified for a minimum of 17 V and 5 mA.

Where the LC1D50AF7 sits among the LC1D frames

Because the dimensions match the neighbouring ratings, an uprate from 50 A to 65 A inside the same cabinet normally needs no mounting changes, but the power terminals and overload relay must be rechecked. Other coil versions of the same frame that we handle are LC1D50AB7, LC1D50AP7, LC1D50AU7; they carry the same power circuit and differ only in the coil voltage.

Frame AC-3 current AC-3 kW at 380/400 V AC-1 current Body H x W x D Net weight Mechanical life
LC1D40A.. 40 A 18.5 kW 60 A 122 x 55 x 120 mm 0.85 kg 6 Mcycles
LC1D50A (this frame) 50 A 22 kW 80 A 122 x 55 x 120 mm 0.855 kg 6 Mcycles
LC1D65A.. 65 A 30 kW 80 A 122 x 55 x 120 mm 0.86 kg 6 Mcycles

Typical loads are 22 kW pumps, medium compressors, cooling-tower fans and conveyor drives.

Selecting and ordering the LC1D50AF7

  • Motor power or load current at your supply voltage, and the duty category: AC-3 for starting, AC-4 for plugging and inching, AC-1 for resistive loads. This LC1D50AF7 is rated 50 A AC-3 and 80 A AC-1.
  • Coil voltage: this reference is 110 V AC; any other control voltage needs a different suffix, so state the control supply before quoting.
  • Panel space: 122 mm x 55 mm x 120 mm and 0.855 kg for this body, mounted on rail or plate.
  • Overload protection and the fuse or breaker that will be paired with the contactor, using the coordination values above.
  • Any auxiliary or mechanical interlock accessories, the quantity, and whether the unit is for new work or a replacement of an existing LC1D device.

Mounting, wiring and commissioning of the LC1D50AF7

Mount the LC1D50AF7 on a 35 mm rail or screw it to a plate with the clearances of the installation sheet. The datasheet lists a flexible power conductor range of 1 to 35 mm² on connector 1 and 1 to 25 mm² on the second connector (without cable end), with a power-terminal torque of 2.5, 5, 8 N.m; the control terminals take 1.7 N.m on this frame except where the datasheet states otherwise. Keep control cabling apart from the power cables and fit the protective cover.

Typical applications of the LC1D50AF7 in Oman and the GCC

In Oman and the GCC the LC1D50AF7 is typically found in MCC buckets and local starter panels for water and desalination pumps, HVAC fans and cooling-water circuits. Summer panel temperatures make the ambient limit in the datasheet relevant: operation is listed from -40 to 60 °C, with derating between 60 and 70 °C. The 22 kW class matches the pump and fan motors found on utility and building services.

On construction and industrial sites around Muscat, Sohar and Salalah the LC1D50AF7 replaces or extends starters on conveyors, crushers, compressors and washdown pumps. Dust and humidity make enclosure ratings and regular cleaning important. The datasheet lists a protective treatment of TH conforming to IEC 60068-2-30, which is relevant for damp heat.

Documents and quotation

A datasheet for the LC1D50AF7 is attached on this page, listing the electrical, mechanical and environmental data used above. Send us the part number, quantity and application and we will confirm availability and a quotation.

Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Other Models in the Se Lc1d 50 Range

Seven Star LLC supplies models from the Se Lc1d 50 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric LC1D50AB7 50 A TeSys Deca ContactorContactors & Overload RelaysView details
Schneider Electric LC1D50AF7 50 A TeSys Deca ContactorContactors & Overload RelaysYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Schneider Electric LC1D50AF7 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric LC1D50AF7 50 A TeSys Deca

Answers from our engineering team on installation, compatibility and integration.

01What is the rated current of the LC1D50AF7?
The datasheet lists 50 A in AC-3 and 80 A in AC-1 at up to 440 V AC, both for operation below 60 °C.
02What coil does the LC1D50AF7 use?
The control circuit voltage is 110 V AC 50/60 Hz. It is an AC coil for 50/60 Hz without a built-in suppressor module.
03Does the LC1D50AF7 have auxiliary contacts?
The datasheet lists 1 NO + 1 NC, mechanically linked, with the NC acting as a mirror contact to IEC 60947-4-1.
04What ambient temperature is allowed for the LC1D50AF7?
The permissible ambient around the device is -40 to 60 °C. Operating altitude is 0 to 3000 m.
05Which certifications does the LC1D50AF7 list?
The datasheet lists CCC; UL; CB Scheme; CSA; CE; UKCA; Marine; EAC. Always confirm the approval needed by your project against the exact reference.