Schneider Electric A9Z61425 Acti9 iID 4P 25 A 30 mA B-SI RCCB
Description
A9Z61425: Acti9 iID 4P 25 A 30 mA type B-SI RCCB
The A9Z61425 is a Schneider Electric Acti9 iID residual current circuit breaker with 4 poles, a rated current of 25 A, a sensitivity of 30 mA and an earth-leakage protection class of type B-SI (Super Immunised). Type B covers smooth DC residual current as well as the waveforms of types A and AC, which is why this reference is listed by the datasheet for photovoltaic, three-phase speed drive and lift applications. Seven Star LLC supplies the A9Z61425 in Oman and the GCC as an independent supplier based in Muscat.
The reference is not decoded by the datasheet, so rely on the parameters on this page: 4P, 25 A, 30 mA, 400 V AC at 50 Hz and type B-SI. It is wider than the single-phase A9R devices, at 72 mm for 8 modules of 9 mm, and deeper at 73 mm.
Indicators and operation of the A9Z61425
The front carries the toggle with ON/OFF indication, a contact position indicator, a green LED showing that voltage is present and a trip indicator. The LED matters because a type B device needs supply to monitor smooth DC leakage in its electronics, while the tripping itself is listed as voltage independent. The datasheet does not describe the exact behaviour on loss of supply, so consult the manufacturer instructions for that.
The front also has a regular-test button. Press it after commissioning and then at the interval your maintenance plan sets; the toggle must be reset by hand after a trip.
Why type B-SI matters for the A9Z61425
Standard RCCBs of type AC and type A do not reliably detect smooth DC residual current. Equipment such as three-phase variable speed drives, photovoltaic inverters and lift controllers can produce that kind of fault current, and a DC component can also magnetise the core of a lower-class device and blind it to ordinary AC faults. The datasheet therefore lists this unit for photovoltaic, 3P speed drive and lift use, with type B-SI protection.
The SI marking means Super Immunised. The datasheet lists an 8/20 µs impulse withstand of 3 kA, tested to EN/IEC 61008-1, and an overvoltage category of IV. Those values relate to resistance against surge-induced nuisance tripping, though the manufacturer’s own test report is the place to confirm anything beyond what the datasheet states.
Technical specifications of the A9Z61425
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / A9Z61425 |
| Range / product name | Acti9 / Acti9 iID |
| Product type | Residual current circuit breaker (RCCB) |
| Poles | 4P |
| Rated current [In] | 25 A |
| Earth-leakage sensitivity | 30 mA |
| Earth-leakage protection class | Type B-SI (Super Immunised) |
| Time delay | Instantaneous |
| Device application | Photovoltaic / 3P speed drive / Lift |
| Residual current tripping | Voltage independent |
| Network type / frequency | AC / 50 Hz |
| Rated operational voltage [Ue] | 400 V AC 50 Hz |
| Rated insulation voltage [Ui] | 500 V |
| Rated impulse withstand [Uimp] | 6 kV |
| Rated breaking and making capacity | Idm 1500 A / Im 1500 A |
| Rated conditional short-circuit current | 10 kA |
| Impulse withstand 8/20 µs | 3 kA (EN/IEC 61008-1) |
| Neutral position | Left |
| Device location in system | Outgoer; group incomer |
| Control / signalling | Toggle; contact position indicator; ON/OFF indication; green LED for voltage presence; trip indicator |
| Mounting | Clip-on, 35 mm DIN rail |
| Width | 72 mm (8 × 9 mm pitches) |
| Height / depth | 88 mm / 73 mm |
| Net weight | 415 g |
| Colour | White (RAL 9003) |
| Terminals | Front, double terminal: 1–35 mm² rigid; 1–25 mm² flexible and with ferrule. Back, double terminal: 1–25 mm² rigid; 1–16 mm² flexible and with ferrule |
| Wire stripping / torque | 14 mm / 3.5 N.m, top or bottom |
| Locking | Padlocking device |
| Mechanical / electrical durability | 20000 / 15000 cycles |
| Standards | EN/IEC 61008-1, EN/IEC 61008-2-1, IEC/EN 62423, VDE 0664 |
| Quality labels | VDE, NF, IMQ, KEMA |
| Product certifications | CCC |
| Degree of protection | IP20; IP40 in modular enclosure (IEC 60529); IK05 |
| Pollution degree / overvoltage category | 3 / IV |
| Operating altitude | 0–2000 m |
| Operating temperature | -25 to 60 °C |
| Storage temperature | -40 to 85 °C |
| Packing | 1 piece, 440.000 g; carton of 27 |
| Warranty | 18 months |
Selection checklist for the A9Z61425
- Supply: 400 V AC, 50 Hz, three phases and neutral.
- Load current: not above 25 A through the device, with a short-circuit device upstream.
- Fault waveform: type B-SI for loads that can generate smooth DC residual current, such as drives and PV inverters.
- Sensitivity: 30 mA for the role of the stage, personal, fire-risk or upstream discrimination.
- Space: 8 modules, 72 mm of rail, 73 mm deep.
- Terminals: double terminals, with a screw shield supplied.
Ratings and environment of the A9Z61425
The datasheet lists 25 A rated current, 500 V insulation voltage, 6 kV impulse withstand, pollution degree 3 and 20000 mechanical and 15000 electrical cycles. Operating temperature is -25 to 60 °C and storage is -40 to 85 °C, with operation up to 2000 m altitude. Protection is IP20 on the device, IP40 in a modular enclosure and IK05 against impact.
Photovoltaic and drive panels in Oman often run hot, so allow spacing from inverters, chokes and large contactors. The listed 60 °C is an ambient figure for the device, and the air inside a closed board can be well above room temperature.
Typical uses of the A9Z61425 in Oman and the GCC
In the region this unit is a candidate for desalination auxiliaries, workshop machinery boards and variable speed drives on pumps and fans, where plain type A protection may not cover the DC content of the fault. Solar plants, pumping stations and buildings with lifts are the obvious fits. The final choice of RCD type is normally set by the equipment manufacturer and the project specification, so confirm it before ordering.
Sensitivity and discrimination: 30 mA on the A9Z61425
With 30 mA and no delay, the A9Z61425 acts as a final-stage device for personal protection.
The table below places the A9Z61425 among the seven type B-SI references in this range. The 30 mA devices suit the protection of people, the 300 mA instantaneous devices suit fire-risk protection, and the 300 mA S devices are the upstream partners that allow discrimination.
| Part number | Rating | Sensitivity | Delay | Impulse withstand 8/20 µs | Width |
|---|---|---|---|---|---|
| A9Z61425 (this page) | 25 A | 30 mA | Instantaneous | 3 kA | 72 mm |
| A9Z61440 | 40 A | 30 mA | Instantaneous | 3 kA | 72 mm |
| A9Z63440 | 40 A | 300 mA | Instantaneous | 3 kA | 72 mm |
| A9Z64425 | 25 A | 300 mA | Instantaneous | 3 kA | 72 mm |
| A9Z64440 | 40 A | 300 mA | Instantaneous | 3 kA | 72 mm |
| A9Z65440 | 40 A | 300 mA | Selective | 5 kA | 72 mm |
| A9Z65463 | 63 A | 300 mA | Selective | 5 kA | 72 mm |
Information to send with an RFQ for the A9Z61425
- Exact reference A9Z61425 and the quantity needed.
- Application, for example PV, drive or lift, and the equipment manufacturer’s RCD requirement.
- Supply voltage and earthing system.
- Upstream protective device and its rating.
- Whether discrimination with 30 mA stages below is required.
- Delivery location and timeline.
Before ordering, check that the board enclosure, busbar arrangement and neighbouring devices leave enough room for heat to escape, since crowded boards in hot rooms run closer to their limits than the rated ambient suggests.
Keep a record of the installed ratings on the board schedule and note the supply voltage at commissioning, because later extensions and fault investigations depend on knowing exactly what protects each circuit.
Documents and quotation
The Schneider Electric datasheet for the A9Z61425 is attached on this page and holds the full specification summarised above. It is dated 8 Nov 2026 as printed on the manufacturer’s document.
Send us the reference A9Z61425, quantity and delivery location and Seven Star LLC will reply to your request. We supply as an independent supplier based in Muscat and do not act for the manufacturer.
Datasheets & Documents
- Datasheet Schneider Electric A9Z61425 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric A9Z61425 Acti9 iID 4P 25 A 30 mA
Answers from our engineering team on installation, compatibility and integration.
01What does the A9Z61425 protect against?
It is a 4P RCCB with 30 mA sensitivity and type B-SI protection, covering AC, pulsating DC and smooth DC residual current. It gives no overload or short-circuit protection, so a device of no more than 25 A is needed upstream.
02Which applications does the datasheet list for the A9Z61425?
The datasheet lists photovoltaic, 3P speed drive and lift applications for this reference.
03What supply is the A9Z61425 rated for?
400 V AC at 50 Hz, 4 poles, 25 A, with a 500 V insulation voltage and a 6 kV impulse withstand.
04What size does the A9Z61425 have?
It is 72 mm wide, 88 mm high and 73 mm deep (8 modules of 9 mm), weighs 415 g and clips onto a 35 mm DIN rail.
05What operating temperature is listed for the A9Z61425?
The datasheet lists -25 to 60 degrees C for operation and -40 to 85 degrees C for storage, with IP20 protection and IP40 in a modular enclosure.