Brand:

Pepperl+Fuchs KFD2-VR-Ex1.19 Voltage Repeater, -10 to 10 V

Description

Pepperl+Fuchs KFD2-VR-Ex1.19 overview

The Pepperl+Fuchs KFD2-VR-Ex1.19 is a one-channel isolated voltage repeater from the K-System of Pepperl+Fuchs. It transfers voltage signals from a hazardous area to the safe area: the input voltage at terminals 4 and 5 is repeated at terminals 7 and 8, with terminals 4 and 8 sharing the same polarity. The datasheet states that it repeats voltage signals from magnetic pickups, transducers and flow meters between minus 10 V and 10 V with signal frequencies up to 1.2 kHz.

The input resistance is at least 10 megohm and the offset voltage is below 2 mV, so the module barely loads the signal source. The output resistance is up to 20 ohm, the supply is 20 to 35 V DC from the Power Rail or terminals 11 and 12, and the housing is the 20 mm wide type B1. The datasheet was released on 25 November 2021, and the module is listed for hazardous areas with marking [Ex ia Ga] IIC, [Ex ia Da] IIIC and [Ex ia Ma] I.

Key features of the Pepperl+Fuchs KFD2-VR-Ex1.19

  • One-channel isolated voltage repeater for hazardous-area signals
  • Transmission range minus 10 V to 10 V, input resistance at least 10 megohm
  • Cut-off frequency 1.2 kHz at minus 3 dB; rise time up to 0.4 ms
  • Deviation after calibration plus or minus 5 mV at 20 degrees C
  • Offset voltage below 2 mV and below 7 nA
  • Supply 20 to 35 V DC through Power Rail or terminals 11 and 12, current below 25 mA
  • Marking [Ex ia Ga] IIC, [Ex ia Da] IIIC and [Ex ia Ma] I
  • Housing type B1, 20 mm wide, IP20, minus 20 to 60 degrees C

KFD2-VR-Ex1.19 technical specifications

The values below are taken from the manufacturer datasheet of the KFD2-VR-Ex1.19, release date 2021-11-25. Always confirm the current datasheet and the certificates before final engineering.

Parameter Value
Model KFD2-VR-Ex1.19, Voltage Repeater, 1-channel isolated barrier
Signal type Analog input
Rated supply voltage 20 to 35 V DC (Power Rail or terminals 11+, 12-)
Rated current Below 25 mA
Input (field side) Terminals 4+, 5-; transmission range minus 10 V to 10 V
Input resistance At least 10 megohm
Offset voltage / current Below 2 mV / below 7 nA
Output (control side) Terminals 7-, 8+; voltage minus 10 V to 10 V
Output resistance Up to 20 ohm
Cut-off frequency 1.2 kHz (-3 dB)
Deviation after calibration Plus or minus 5 mV at 20 degrees C
Influence of ambient temperature Below 0.005 percent of range per K
Rise time Up to 0.4 ms
Isolation Output to supply: functional insulation, 50 V AC
Hazardous-area marking (1)GD, (M1) [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I; certificate BAS 01 ATEX 7262
Input Ex ia values Uo 18 V, Io 4.2 mA, Po 19 mW
Zone 2 certificate BASEEFA 10 ATEX 0079X, marking Ex ec IIC T4 Gc
IECEx IECEx BAS 10.0040X
Ambient temperature Minus 20 to 60 degrees C
Dimensions / mass 20 x 107 x 115 mm (W x H x D), housing type B1 / approx. 100 g
Degree of protection / mounting IP20, screw terminals / 35 mm DIN rail

Check the Ex ia input values against the pickup or transducer you connect. Passive magnetic pickups are normally simple apparatus, but powered transducers must be assessed against the entity parameters.

Typical applications in oil and gas, utilities, water and manufacturing

Signals from magnetic pickups, transducers and flow meters sometimes need to cross from a hazardous area to the safe area without being converted to current. The KFD2-VR-Ex1.19 repeats such voltage signals in the range of minus 10 V to 10 V with galvanic isolation, so instruments such as turbine meters and speed pickups can be read by controllers in the safe area.

Typical uses in the Middle East include turbine flow metering on pipelines and metering skids, speed pickup circuits on machines in gas compression and power stations, and special transducer signals in laboratory and test facilities. Because the signal frequency can reach 1.2 kHz, the module is suitable for many pulse-type signals as well as slowly varying DC levels.

Selection and compatibility notes for KFD2-VR-Ex1.19

Check that the source really produces a voltage signal within minus 10 V to 10 V and that its output can tolerate the 10 megohm minimum input resistance of the KFD2-VR-Ex1.19. Then check that the control system input expects a voltage, since the output resistance is up to 20 ohm and the module repeats the input at its output with the same polarity relationship defined on terminals 4 and 8.

For pulse signals, verify that the frequency stays within the cut-off frequency of 1.2 kHz at minus 3 dB, because higher frequencies will be attenuated. If your signal uses current rather than voltage, send us the loop data and we will suggest another K-System module.

Installation and commissioning of the KFD2-VR-Ex1.19

Before mounting the KFD2-VR-Ex1.19, confirm the field device and cable parameters against the entity values in the datasheet and the certificate, and decide whether the module will be powered from a Power Rail or from its own supply terminals. Mount it on a 35 mm DIN rail in a clean, ventilated cabinet in the safe area, keep hazardous-area and safe-area wiring physically separated and labelled, and respect the spacing and marking required by your site rules for intrinsically safe circuits. Observe the polarity relation between terminals 4 and 8 of the KFD2-VR-Ex1.19 so that the repeated signal keeps its sign at the control system input.

Wire the KFD2-VR-Ex1.19 only to the terminal assignment printed in the wiring diagram, tighten the screws and check that no strands are left outside the clamp. After applying the supply, check the power indication, then simulate the field signal and prove the complete loop from field to control system before the plant is handed over. Record the as-found readings so that later loop checks of the KFD2-VR-Ex1.19 can be compared with the commissioning values.

Maintenance and service life

The KFD2-VR-Ex1.19 has no serviceable parts, so maintenance is mostly inspection. During planned shutdowns, check terminals for looseness and corrosion, verify the supply voltage at the module, and repeat the loop check that was recorded at commissioning. In coastal and humid locations such as Muscat, Sohar and Duqm, a clean, dry and sealed cabinet greatly extends the life of any electronic interface. Because the KFD2-VR-Ex1.19 repeats the input faithfully, a noisy output normally indicates a problem with pickup wiring, shielding or grounding, so check those first.

If a loop drifts out of tolerance or the unit shows no power indication with a healthy supply, replace the module instead of attempting a repair, and keep the replacement documentation in the loop folder. Certified intrinsically safe equipment must not be modified, and any change to cabling, load or field device should be re-assessed against the KFD2-VR-Ex1.19 entity parameters before it returns to service.

Related products and ordering notes

Customers who ask for the KFD2-VR-Ex1.19 often need neighbouring models or accessories from the same system, such as other KFD2 voltage repeaters, KFD2-VR4 and KFD2-VC types, the Power Rail and the power feed modules. If you are standardising a cabinet on one family, send us the loop list and we can quote the matching modules together.

When you send an enquiry for the KFD2-VR-Ex1.19, quote the full part number exactly as printed on the nameplate, the quantity and the intended application. If you are replacing an installed unit, a photograph of the nameplate helps us confirm the exact variant you need. We can arrange a quotation with delivery to Oman and across the GCC.

Frequently asked questions about KFD2-VR-Ex1.19

The KFD2-VR-Ex1.19 is a one-channel voltage repeater for minus 10 V to 10 V signals up to 1.2 kHz, with 10 megohm input resistance, 20 ohm output resistance and a 20 to 35 V DC supply.

Documents and quotation

A copy of the manufacturer datasheet for the KFD2-VR-Ex1.19 is attached to this page for your engineering review. To request a quotation, send the RFQ with the part number KFD2-VR-Ex1.19, the quantity, the delivery location and any certification or documentation requirements, and we will reply with availability and lead time. Please check the specification against your loop or system requirements before ordering.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with Pepperl+Fuchs. Product names and part numbers are used only to identify the item you ask for.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.

Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.

Pepperl+Fuchs company profile

Founded 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs
Headquarters Mannheim, Germany
Ownership Privately owned (Pepperl+Fuchs SE)
Origins Radio repair workshop that began making replacement transformers
Product families Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures

Milestones

  • 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
  • 1958: The first proximity switch is developed (some company sources say 1959).

Pepperl+Fuchs product families on this page

On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.

Where Pepperl+Fuchs equipment is used

Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.

Pepperl+Fuchs products we list

Family Examples
Isolator & Barrier HiD2030 SMART Transmitter Power Supply w…, KFD2-SR2-Ex2.W K-System Isolated Switch…, KFD2-UT2-Ex2 Universal Temperature Conve…
Industrial Computers Tab-Ex 05 DZ1 WWAN Hazardous Area Tablet, Smart-Ex® 03 DZ2 smartphone for Zone 2/2…
Inductive Proximity Sensors NJ2-12GK-SN NAMUR Inductive Sensor
Power Modules PS1000-A6-24.20 Power Supply 24 VDC 20 A
Photoelectric Sensors R101 Retro-Reflective Photoelectric Sensor
Laser Distance, LiDAR & Radar Sensors R2000 2-D LiDAR Laser Scanner

Ordering Pepperl+Fuchs parts: what we need

Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.

Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.

FAQ

Questions about the Pepperl+Fuchs KFD2-VR-Ex1.19 Voltage Repeater, -10

Answers from our engineering team on installation, compatibility and integration.

01What does the KFD2-VR-Ex1.19 repeat?
It repeats voltage signals from magnetic pickups, transducers and flow meters between minus 10 V and 10 V from a hazardous area to a safe area.
02What is the frequency limit?
The datasheet gives a cut-off frequency of 1.2 kHz at minus 3 dB.
03What is the input resistance?
The input resistance is at least 10 megohm, so the source is hardly loaded.
04What supply does the KFD2-VR-Ex1.19 need?
It needs 20 to 35 V DC from the Power Rail or terminals 11+ and 12-, with a current below 25 mA.
05How do I order the KFD2-VR-Ex1.19?
Send an RFQ with the part number KFD2-VR-Ex1.19, the quantity and the delivery location in Oman or the GCC, and Seven Star LLC will reply with availability and lead time.