Pepperl+Fuchs KCD2-STC-Ex1.ES SMART Transmitter Supply, SIL 3
Description
Pepperl+Fuchs KCD2-STC-Ex1.ES overview
The Pepperl+Fuchs KCD2-STC-Ex1.ES is a one-channel, 12.5 mm wide isolated barrier from Pepperl+Fuchs that supplies 2-wire transmitters in a hazardous area and can also be used with current sources. It transfers the analog input signal to the safe area as an isolated current value and supports bi-directional communication for SMART transmitters that use current modulation to send data and voltage modulation to receive data. HART is the protocol listed in the datasheet.
Compared with the standard KCD2-STC-Ex1, the .ES version is stated for SIL 3 with systematic capability SC 3, adds line fault detection with downscaling to 3 mA or less and upscaling to 22 mA or more, and signals faults with LEDs and a collective error message through the fault bus. The output can again be configured by DIP switches as a current source, a current sink or a voltage source. The datasheet was released on 1 June 2023.
Key features of the Pepperl+Fuchs KCD2-STC-Ex1.ES
- Slim 12.5 mm housing type A2 for dense marshalling cabinets
- SIL 3 with systematic capability SC 3 according to IEC/EN 61508
- Line fault detection with downscale to 3 mA or less and upscale to 22 mA or more
- Fault bus output (open collector transistor) for the collective error message
- Output selectable as current source, current sink or voltage source via DIP switches
- Reverse polarity protected input limited to approx. 27 mA
- Test sockets for HART communicators
- Supply 19 to 30 V DC from Power Rail or terminals 9 and 10; ambient range minus 20 to 70 degrees C
KCD2-STC-Ex1.ES technical specifications
The values below are taken from the manufacturer datasheet of the KCD2-STC-Ex1.ES, release date 2023-06-01. Always confirm the current datasheet and the certificates before final engineering.
| Parameter | Value |
|---|---|
| Model | KCD2-STC-Ex1.ES, SMART Transmitter Power Supply, 1-channel isolated barrier |
| Signal type | Analog input |
| Safety Integrity Level / systematic capability | SIL 3 / SC 3 |
| Rated supply voltage | 19 to 30 V DC, ripple up to 10 percent (Power Rail or terminals 9+, 10-) |
| Rated current | Up to 50 mA |
| Power dissipation / consumption | Up to 800 mW / up to 1.2 W |
| Input | 4 to 20 mA limited to approx. 27 mA, reverse polarity protected; terminals 1+, 2-; 3+, 4- |
| Line fault detection | Downscaling 3 mA or less; upscaling 22 mA or more |
| Available voltage (terminals 1+, 2-) | At least 15 V at 20 mA |
| Output, source mode | 4 to 20 mA or 1 to 5 V (internal resistor 250 ohm, 0.1 percent); load 0 to 300 ohm; terminals 5-, 6+ |
| Output, sink mode | 4 to 20 mA, operating voltage 16 to 28 V |
| Ripple | Up to 20 mV rms |
| Fault indication output | Fault bus signal, open collector transistor |
| Deviation at 20 degrees C | Up to plus or minus 20 microamperes (4 to 20 mA modes); up to 10 mV (1 to 5 V) |
| Hazardous-area marking | (1)G [Ex ia Ga] IIC; certificate CESI 10 ATEX 071 |
| Field terminals 1+, 2- | Uo 25.2 V, Io 100 mA, Po 630 mW, Ci 5.7 nF, Li negligible |
| Zone 2 certificate | CESI 19 ATEX 005 X, marking Ex ec IIC T4 Gc |
| Approvals listed | UL approval E106378; IECEx CES 11.0001X |
| Ambient temperature | Minus 20 to 70 degrees C |
| Dimensions / mass | 12.5 x 119 x 114 mm (W x H x D), housing type A2 / approx. 100 g |
| Degree of protection / mounting | IP20, screw terminals / 35 mm DIN rail |
The datasheet states the output voltage drop for the 250 ohm internal resistor as 5 V at 20 mA. Include that figure in the loop load calculation when the resistor is used.
Typical applications in oil and gas, utilities, water and manufacturing
Loop-powered SMART transmitters for pressure, differential pressure, level and temperature are everywhere in refineries, gas gathering stations and desalination plants in Oman, and every one of them that sits in a hazardous area needs an interface to the control room. The KCD2-STC-Ex1.ES fills that role in marshalling cabinets that feed DCS and PLC analog input cards, while letting HART communication pass through for configuration and diagnostics.
In utilities, water and wastewater works, and in manufacturing sites across the GCC, the same module is used where a transmitter is installed near a fuel store, a chemical dosing area or a biogas digester. Maintenance teams value the integrated test sockets because a handheld communicator can be connected without opening the loop, which shortens routine calibration and loop-check work on the KCD2-STC-Ex1.ES channel.
Selection and compatibility notes for KCD2-STC-Ex1.ES
Start with the transmitter. Confirm that its supply voltage requirement, its maximum current and its entity parameters match the field-side data of the KCD2-STC-Ex1.ES, and confirm that the control system input accepts the output type of the module. The loop must also offer enough load resistance for HART communication, which is why the datasheet describes an internal 250 ohm resistor that can be used when the loop resistance is too low.
Next consider the cabinet. Devices of this family snap onto a Power Rail or are supplied through dedicated terminals, so decide early whether power will be distributed by rail or wired point to point. If your plant standard calls for a different housing width, channel count or SIL level, tell us before ordering so that we can compare neighbouring variants of the KCD2-STC-Ex1.ES against your loop list.
Installation and commissioning of the KCD2-STC-Ex1.ES
Before mounting the KCD2-STC-Ex1.ES, confirm the field device and cable parameters against the entity values in the datasheet and the certificate, and decide whether the module will be powered from a Power Rail or from its own supply terminals. Mount it on a 35 mm DIN rail in a clean, ventilated cabinet in the safe area, keep hazardous-area and safe-area wiring physically separated and labelled, and respect the spacing and marking required by your site rules for intrinsically safe circuits. Use the Power Rail if you want the fault bus collective message to reach your monitoring system, and set the DIP switches for the required output mode of the KCD2-STC-Ex1.ES before powering up.
Wire the KCD2-STC-Ex1.ES only to the terminal assignment printed in the wiring diagram, tighten the screws and check that no strands are left outside the clamp. After applying the supply, check the power indication, then simulate the field signal and prove the complete loop from field to control system before the plant is handed over. Record the as-found readings so that later loop checks of the KCD2-STC-Ex1.ES can be compared with the commissioning values.
Maintenance and service life
The KCD2-STC-Ex1.ES has no serviceable parts, so maintenance is mostly inspection. During planned shutdowns, check terminals for looseness and corrosion, verify the supply voltage at the module, and repeat the loop check that was recorded at commissioning. In coastal and humid locations such as Muscat, Sohar and Duqm, a clean, dry and sealed cabinet greatly extends the life of any electronic interface. Alarm values of 3 mA or less and 22 mA or more indicate line faults, so make sure your control system treats these values as diagnostic alarms when you test the KCD2-STC-Ex1.ES.
If a loop drifts out of tolerance or the unit shows no power indication with a healthy supply, replace the module instead of attempting a repair, and keep the replacement documentation in the loop folder. Certified intrinsically safe equipment must not be modified, and any change to cabling, load or field device should be re-assessed against the KCD2-STC-Ex1.ES entity parameters before it returns to service.
Related products and ordering notes
Customers who ask for the KCD2-STC-Ex1.ES often need neighbouring models or accessories from the same system, such as the standard KCD2-STC-Ex1, other KCD2 slim isolated barriers and the Power Rail with its fault bus. If you are standardising a cabinet on one family, send us the loop list and we can quote the matching modules together.
When you send an enquiry for the KCD2-STC-Ex1.ES, quote the full part number exactly as printed on the nameplate, the quantity and the intended application. If you are replacing an installed unit, a photograph of the nameplate helps us confirm the exact variant you need. We can arrange a quotation with delivery to Oman and across the GCC.
Frequently asked questions about KCD2-STC-Ex1.ES
The KCD2-STC-Ex1.ES is a slim SIL 3 barrier for 2-wire transmitters with configurable source, sink or voltage output, line fault detection and a fault bus output.
Documents and quotation
A copy of the manufacturer datasheet for the KCD2-STC-Ex1.ES is attached to this page for your engineering review. To request a quotation, send the RFQ with the part number KCD2-STC-Ex1.ES, the quantity, the delivery location and any certification or documentation requirements, and we will reply with availability and lead time. Please check the specification against your loop or system requirements before ordering.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with Pepperl+Fuchs. Product names and part numbers are used only to identify the item you ask for.
Other Models in the K System Range
Seven Star LLC supplies models from the K System range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Pepperl+Fuchs KFD2-STC4-Ex1 SMART Transmitter Power Supply | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-STC4-Ex1.2O SMART Transmitter Supply, 2 Outputs | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-CD-Ex1.32 Current Driver for I/P Converters | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-CD-Ex1.32-13 Voltage Driver, 4-20 mA to 0-10 V | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-UT2-Ex1-1 Universal Temperature Converter | Isolator & Barrier | View details |
| Pepperl+Fuchs KCD2-STC-Ex1.ES SMART Transmitter Supply, SIL 3 | Isolator & Barrier | You are viewing this model |
Datasheets & Documents
- Datasheet KCD2-STC-Ex1.ES Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs KCD2-STC-Ex1.ES SMART Transmitter
Answers from our engineering team on installation, compatibility and integration.
01What is different about the KCD2-STC-Ex1.ES?
It is stated for SIL 3, adds line fault detection with downscale and upscale values, and provides a fault bus collective error output.
02What does the line fault detection signal?
The datasheet gives downscaling of 3 mA or less and upscaling of 22 mA or more.
03Is the output configurable?
Yes. DIP switches select current source, current sink or voltage source, with source mode giving 4 to 20 mA or 1 to 5 V.
04What is the temperature range of the KCD2-STC-Ex1.ES?
The ambient temperature range is minus 20 to 70 degrees C.
05How do I order the KCD2-STC-Ex1.ES?
Send an RFQ with the part number KCD2-STC-Ex1.ES, the quantity and the delivery location, and Seven Star LLC will reply with availability and lead time.