Parker SCP-015-74-02 SCP Pressure Sensor, -1 to 15 bar
Description
SCP-015-74-02 pressure sensor for low-pressure and vacuum work
The Parker SCP-015-74-02 is a analogue pressure sensor from the SCP (SensoControl) range, built as a diagnostic sensor for Parker hand-held and portable measuring instruments. This is the lowest-range member of the analogue SCP family, covering -1 to 15 bar. That window reaches slightly below atmospheric pressure, so the sensor can read vacuum and suction conditions as well as positive pressure. It is made of stainless steel, uses a strain-gauge measuring element and is delivered with a diagnostic adapter installed, so it can be connected to a measuring point in seconds.
How to read the part number SCP-015-74-02
| Element | Meaning |
|---|---|
| SCP | Pressure sensor from the SCP series |
| 015 | Measuring range code: -1 to 15 bar |
| 74 | Analogue output for Parker hand meters |
| 02 | Analogue 5-pin electrical connection |
Parker also lists a PD-adapter version of most analogue ranges, with the suffix -PD, and a calibration-certificate version with the prefix K-. This page covers the standard version SCP-015-74-02.
SCP-015-74-02 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Parker / SCP-015-74-02 |
| Product | Pressure sensor, SCP series (SensoControl) |
| Measuring range | -1…15 bar (-14.5…218 psi) |
| Output type | analogue signal for hand meters |
| Technology | Strain gauge (DMS) |
| Accuracy (full scale) | ± 0.5 % + 0.2 %/year |
| Electrical connection | 5-pin plug-in connection |
| Process connection | 1/4" BSPP, supplied with a diagnostic adapter (M16x2) fitted |
| Housing / seal | Stainless steel / FKM |
| Body diameter | 22 mm |
| Weight | approx. 200 g |
| Ambient temperature | -25…+85 °C |
| Media temperature | -25…+105 °C |
| Storage temperature | -20…+85 °C |
| Shock / vibration | 50 g / 11 ms (IEC 60068-2-27); 20 g (IEC 60068-2-6) |
| Load cycles | 100 million |
| Protection class | IP54 (EN 60529) |
| Specifications met | CE |
How the SCP-015-74-02 measures pressure
Inside the stainless-steel body a strain-gauge sensing element converts the pressure acting on it into an electrical signal. The signal is delivered as an analogue value through the 5-pin plug-in connector to a compatible Parker hand meter. Because the sensing element is small and stiff, the sensor follows fast pressure changes and can record short peaks that a mechanical gauge would miss.
The sensor is intended to be used with a measuring hose and a test-point coupling rather than being threaded permanently into a line. The diagnostic adapter that is already installed on the 1/4" BSPP port ends in an M16x2 female thread, which matches the EMA-3 measuring connection used on Parker test points. This keeps the connect-and-disconnect time short and avoids the use of loose fittings.
Instruments and accessories that work with SCP-015-74-02
The analogue SCP sensors work with the Parker Serviceman Plus SCM-155-0-02 and with the Service Master CONNECT SCM-600 when it is fitted with an analogue input module SCMI-600-01 or SCMI-600-03. The sensor connects to the meter through SCK-102 cables, which Parker lists as SCK-102-03-02 (3 m), SCK-102-05-02 (5 m) and SCK-102-05-12 (5 m extension, with a female end). Related sensors from the same catalogue include the other analogue ranges (SCP-015-74-02, SCP-060-74-02, SCP-150-74-02, SCP-400-74-02, SCP-600-74-02 and SCP-1000-74-02) and the combined pressure and temperature sensors SCPT-xxx-02-02.
The measuring chain also includes the measuring hose (SMA3 series), the adapter SCA-EMA-3/3 and the measuring connection EMA-3 on the system side. Check that each element is rated for the pressure you intend to measure.
Choosing the SCP-015-74-02 range
Choose the 015 range when the highest pressure you expect is a few bar. Low-pressure circuits such as pump inlet lines, boost and charge circuits, return lines, lube circuits and compressed air branches fit well, and so does any suction line where the pressure drops below atmosphere. For anything that can see hydraulic working pressure or a pressure spike, step up to the 060 or higher range instead, because the narrow span of this version is chosen for resolution at low pressure, not for survivability at high pressure. The catalogue shows a modest overload rating for this range, so confirm the figure in the current Parker catalogue before using it where surges are possible.
- Pump inlet and suction-line checks that dip below atmospheric pressure
- Charge and boost circuits of closed-loop hydrostatic drives
- Return-line back pressure on filtered circuits
- Instrument air and nitrogen branch verification
Selection and ordering checklist for SCP-015-74-02
- Confirm the highest working pressure and the highest expected peak, and compare both with the -1 to 15 bar range and the overload rating.
- Confirm that your hand meter or data logger has a matching analogue sensor input.
- Decide whether you need the standard adapter, the PD adapter variant or a calibration certificate (K- prefix).
- Check the process connection: 1/4" BSPP male on the sensor, with an M16x2 female diagnostic adapter.
- Check the media: the sensor housing is stainless steel and the seal is FKM, with a media temperature of -25 to +105 °C.
- Plan the cables and, for CAN, the terminating resistor.
Use, care and maintenance of the SCP-015-74-02
Always depressurise the circuit before connecting or removing the sensor, and use a measuring hose with a rating at or above the highest pressure. Connect the sensor to the test point, then the cable to the meter, and only then pressurise the system. Remove the sensor when the measurement is complete rather than leaving it on the machine, as it is a diagnostic tool and not a permanent transmitter.
Accuracy is stated as ± 0.5 % of full scale plus 0.2 % per year, which means a periodic check or recalibration is part of normal use. Store the sensor in a clean, dry place between jobs, keep the connector clean and dry, and replace the cable when the insulation or the plug shows wear. The sensor is rated IP54, so it should be kept away from jets of water and from heavy contamination when in use.
Where the SCP-015-74-02 is used in Oman and the GCC
Typical use in the region is checking the suction side of lube-oil and hydraulic power packs, verifying charge pressure on closed-loop pumps in mobile and workshop equipment, commissioning instrument air and nitrogen branches on skids, and watching return-line back pressure on filtered circuits. In hot, dusty sites the sensor is normally fitted only for the duration of the test and removed afterwards, which suits its IP54 rating.
Heat is a factor on exposed equipment in the Gulf. The ambient range is -25 to +85 °C and the media range reaches +105 °C, so a sensor left on a sun-heated line should be checked against those limits. Fine dust and humidity are also constant concerns, which makes it wise to cap the connector and the diagnostic adapter when the sensor is stored.
Information to send with an RFQ for SCP-015-74-02
- Part number SCP-015-74-02 and quantity
- Standard, PD adapter or calibration-certificate version
- Meter model or logger that the sensor will connect to
- Cable lengths and accessories needed
- Project name, site and delivery location
Documents and quotation
Send us the part number SCP-015-74-02 and the required quantity, and we will confirm the available documents and the lead time.
Seven Star LLC supplies Parker pressure sensors and other hydraulic and pneumatic products in Oman and the GCC from Muscat.
Reviews (0)
How would you rate this product? Cancel reply
About brand
Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.
Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.
Parker company profile
| Founded | 1917, Cleveland, Ohio, USA, by Arthur L. Parker |
|---|---|
| Headquarters | Cleveland area, Ohio, USA |
| Ownership | Public company, New York Stock Exchange (PH), listed since 1964 |
| First product | Pneumatic brake system for trucks and buses |
| Product families | Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings |
Milestones
- 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
- 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
- 1957: Parker acquires Hannifin and becomes Parker Hannifin.
- 1964: The shares are listed on the New York Stock Exchange.
Parker product lines listed here
Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.
Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.
Where Parker components are used
Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.
Parker products we list
Ordering Parker parts: what we need
Parker part numbers are long and every character counts. Please send:
- Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
- Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
- Filter elements: element number and the housing model it fits
A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.
Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.
Browse Parker products by category: Solenoid Valve, Filtration Elements, Pumps.
FAQ
Questions about the Parker SCP-015-74-02 SCP Pressure Sensor, -1 to 15
Answers from our engineering team on installation, compatibility and integration.
01What is the Parker SCP-015-74-02 used for?
It is a diagnostic pressure sensor for Parker hand-held measuring instruments, used for low-pressure and vacuum work. It is connected through a test point and a measuring hose and is not meant to stay permanently in the line.
02What pressure range does the SCP-015-74-02 cover?
The measuring range is -1 to 15 bar (-14.5 to 218 psi). Check the overload and burst ratings in the current Parker catalogue before using it where pressure surges can occur.
03Which instruments does the SCP-015-74-02 connect to?
It connects to the Parker Serviceman Plus SCM-155-0-02 and to the Service Master CONNECT SCM-600 with an analogue input module, through SCK-102 cables.
04What are the process and electrical connections of the SCP-015-74-02?
The process connection is 1/4" BSPP male, supplied with a diagnostic adapter that has an M16x2 female thread. The electrical connection is a 5-pin plug-in connector with protection class IP54.
05How accurate is the SCP-015-74-02?
The stated accuracy is ± 0.5 % of full scale plus 0.2 % per year, so periodic recalibration or a replacement is advisable. A version with a calibration certificate per ISO 9001 is listed with the prefix K-.