Brand:

Parker Lucifer E131K03 Solenoid Valve

Description

Overview

The Parker Lucifer E131K03 solenoid valve is a direct acting valve from the Lucifer K-series, supplied here as the 3/2-way normally closed version identified in the original listing. The valve has a G1/4 female threaded connection and a brass body, and the original listing identifies the configuration as 24 V dc, IP65, orifice 2.5 mm, working pressure 0-7 bar and flow factor 3.5 L/min.

Direct acting solenoid valves are used where the valve must operate reliably at zero differential pressure, since the solenoid moves the valve directly without relying on the line pressure. The K-series E131K03 is a compact brass valve suitable for air, gas and liquid media in control circuits.

Engineering & Design

In a direct acting valve the solenoid armature is coupled directly to the valve seat, so the valve opens and closes on the solenoid force alone. The E131K03 solenoid valve is a 3/2-way normally closed valve: when the coil is energised the valve switches, and when the coil is de-energised a spring returns it to the closed position.

The valve body is brass with FKM (Viton) seals, and the working temperature range is -10 °C to +100 °C for the fluid, with a maximum operating pressure differential of 7 bar as stated in the original listing. The assembly reference of this example follows the E131K03-492453 configuration with the C2H coil code per the original listing.

Key Features

  • Direct acting E131K03 solenoid valve, 3/2-way, normally closed
  • G1/4 female threaded connection, brass body
  • FKM (Viton) seals, working temperature -10 °C to +100 °C
  • Operating pressure differential 0-7 bar (per original listing)
  • 24 V dc coil, IP65 protection class
  • Compact and lightweight design

Applications

  • The E131K03 solenoid valve is used in pilot and control circuits for air, gas and liquids
  • Zero differential pressure applications
  • General machine and process control
  • Replacement duty for existing E131K03 valves

Specifications

Manufacturer Parker Lucifer (Parker Hannifin)
Model E131K03
Type Direct acting solenoid valve, 3/2-way, normally closed
Connection G1/4 female thread
Orifice 2.5 mm (per original listing)
Pressure range 0-7 bar differential (per original listing)
Body / seals Brass; FKM (Viton)
Coil 24 V dc, IP65 (per original listing)
Temperature -10 °C to +100 °C (fluid)

Compatibility & Integration

The E131K03 solenoid valve connects into the fluid circuit with its G1/4 female threads and to the control circuit with the solenoid coil, which for this example is a 24 V dc coil directly compatible with PLC and relay outputs. The direct acting design means the valve works even with no pressure differential, which is important for vent and drain applications.

Before installation, confirm the media, temperature and pressure of the circuit against the valve rating, and check the compatibility of the FKM seals with the media used. Our team can confirm the configuration against your application before dispatch.

Ordering Information

To order the Parker Lucifer E131K03 solenoid valve from Seven Star LLC, quote the model number and the coil voltage. We confirm availability and delivery to your site in Oman or anywhere in the GCC, and we verify the configuration against your application before dispatch.

Why Seven Star LLC

Seven Star LLC supplies solenoid valves and fluid control components to industrial customers across Oman and the wider GCC region. Every Parker Lucifer E131K03 valve we supply is checked against the model number and configuration before dispatch, and our team confirms the valve matches your application before you order.

FAQ

What is the Parker Lucifer E131K03?

The E131K03 solenoid valve is a direct acting valve from the Lucifer K-series, supplied as a 3/2-way normally closed valve with a G1/4 brass body.

What is the pressure rating of the E131K03?

The operating pressure differential is 0 to 7 bar, per the original listing, and the direct acting design allows operation at zero differential pressure.

Which media can the E131K03 handle?

The valve is suitable for air, gas and liquid media within the rating of the brass body and FKM seals, at fluid temperatures of -10 °C to +100 °C.

What coil voltage does this valve have?

Per the original listing, the coil is 24 V dc with IP65 protection class.

Is the E131K03 normally closed?

Yes, the valve is 3/2-way normally closed: it returns to the closed position by spring when the coil is de-energised.

Identifying the Valve from the Nameplate

Lucifer valves carry the valve type on the body or label, and the coil has its own code and voltage marking. When replacing an installed E131K03 solenoid valve, record both the valve code (including any assembly suffix such as -492453) and the coil label, then confirm:

  • Valve function – 3/2-way normally closed – and the port marking used in the circuit
  • Coil voltage and type (AC or DC) and the connector style
  • Media, pressure and temperature of the application against the valve rating
  • Seal material compatibility with the medium

Valve Installation and Commissioning

Flush the pipework before installation, since particles are the most common cause of leaking seats in small-orifice direct acting valves, and fit a strainer upstream where the medium is not clean. Connect the ports according to the body markings, use suitable thread sealing on the G1/4 connections without letting sealant enter the valve, and never use the coil as a lever when tightening. Wire the coil for the correct voltage and make sure the connector gasket is in place to keep the IP65 rating. On commissioning, cycle the valve several times and check for leakage at the exhaust port in the de-energised state.

Maintenance and Troubleshooting

  • Valve does not switch – check coil voltage at the connector, coil continuity, and whether the pressure differential exceeds the rating
  • Leakage through the exhaust – dirt on the seat or worn seals
  • Coil overheating – wrong voltage, or a continuously energised coil in high ambient temperature
  • Humming or slow response – usually an AC coil issue; check that the correct coil is fitted

Applications in Oman and the GCC

Direct acting 3/2-way valves are used in pneumatic pilot circuits for actuators, instrument air control and small machine functions across the region’s oil and gas, water and manufacturing plants. Seven Star LLC supplies Parker Lucifer valves and coils as complete units or spares, checked against your nameplate data before dispatch.

Related Products

Datasheets & Documents
  • PDF Instruction Manual Parker Lucifer E131K03 Solenoid Valve Manual Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Parker's catalog spans almost everything that moves or controls a fluid, from hydraulic pumps to instrument fittings. The company was founded in 1917 and is based in Cleveland, USA. For process plants in Oman, Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.

Parker product lines listed here

Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.

Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.

Where Parker components are used

Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.

Ordering Parker parts: what we need

Parker part numbers are long and every character counts. Please send:

  • Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
  • Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
  • Filter elements: element number and the housing model it fits

A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.

Frequently Asked Questions

What is the Parker Lucifer E131K03?
The E131K03 solenoid valve is a direct acting valve from the Lucifer K-series, supplied as a 3/2-way normally closed valve with a G1/4 brass body.
What is the pressure rating of the E131K03?
The operating pressure differential is 0 to 7 bar, per the original listing, and the direct acting design allows operation at zero differential pressure.
Which media can the E131K03 handle?
The valve is suitable for air, gas and liquid media within the rating of the brass body and FKM seals, at fluid temperatures of -10 °C to +100 °C.
What coil voltage does this valve have?
Per the original listing, the coil is 24 V dc with IP65 protection class.
Is the E131K03 normally closed?
Yes, the valve is 3/2-way normally closed: it returns to the closed position by spring when the coil is de-energised.