Brand: MICHELL Instruments
Condumax II CD2PSS-AT-HW-MC Transportable Dew-Point Analyzer
Description
Michell CD2PSS-AT-HW-MC overview: transportable hydrocarbon and water dew-point analyzer system with built-in sample system
Michell CD2PSS-AT-HW-MC is the ATEX version of the Condumax II Transportable, a self-contained field system for spot-check measurement of hydrocarbon and water dew point in natural gas. The order sheet describes a 230 VAC unit with built-in sample system, chilled mirror 0.5 °C hydrocarbon dew-point accuracy, capacitive touch screen, pressure reading, flow alarm, Modbus RTU and two 4 to 20 mA outputs.
This page repeats the facts published by the manufacturer for Michell CD2PSS-AT-HW-MC so that engineers, maintenance planners and buyers can confirm the code before sending an enquiry. The photograph shows the Michell product line that the CD2PSS-AT-HW-MC code belongs to, taken from the manufacturer product page.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list CD2PSS-AT-HW-MC so that procurement teams can quote the exact code that appears in the manufacturer documentation.
Key features of CD2PSS-AT-HW-MC
- Self-contained transportable analyzer with sample handling, conditioning and analysis
- Simultaneous hydrocarbon and water dew-point measurement in one analyzer
- 0.5 °C hydrocarbon dew-point accuracy with the fundamental cooled-mirror principle
- Suitable for IEC Zone 1 or 2 hazardous areas and NEC Class I, Division 1, Groups B, C, D
- Maximum 100 barg with 0.06 m3 per hour (1 L/min) flow rate per the order sheet
- 150 data logs stored for operator review
CD2PSS-AT-HW-MC technical specifications
| Parameter | Value |
|---|---|
| Order code | CD2PSS-AT-HW-MC |
| Version | ATEX certified, 230 VAC, hydrocarbon and water dew point (ISO 18453) |
| HC dew-point accuracy | ±0.5 °C (±0.9 °F) |
| Maximum measurement depression | Up to 55 °C (131 °F) from main unit operating temperature |
| Sample flow | 0.03 to 0.06 m3/h (0.5 to 1.0 Nl/min), low-flow alarm |
| Measurement frequency | 6 cycles per hour recommended, 12 maximum |
| Water dew-point range | Calibrated -100 to +20 °C |
| Outputs | Modbus RTU RS485; two 4 to 20 mA outputs |
| Power supply | 110 or 230 V AC, 50/60 Hz, 300 W |
| Operating environment | 0 to +40 °C, maximum 95 % relative humidity |
| Weight | Approximately 60 kg (132 lb) |
| Maximum pressure | 100 barg |
Values above are taken from the manufacturer datasheet and order-code sheet listed on this page. The manufacturer states that specifications can change as part of continuous development, so confirm the current revision when the CD2PSS-AT-HW-MC is part of a tender or a certified installation.
Typical applications of CD2PSS-AT-HW-MC in Oman and the GCC
Spot-check measurements of hydrocarbon and water dew point, field verification of installed online analyzers, periodic measurement at any gas source and process-stage profiling are the uses given by the manufacturer. A transportable unit suits operators with several wellhead or terminal sites across Oman.
- Oil and gas: gas processing plants, wellsites, export pipelines and metering stations
- Utilities and power: turbine fuel gas, instrument air and compressed air systems
- Water and desalination: process air, gas generation and laboratory support
- Manufacturing and laboratories: calibration, electronics, pharmaceutical and industrial gas production
Dew point is the temperature at which water vapour in a gas begins to condense at a given pressure, so a lower dew point means drier gas. Pressure dew point is the value at line pressure and is the figure that matters for compressed air and process gas, while atmospheric dew point refers to the same gas expanded to ambient pressure and reads much lower. Moisture can also be expressed in ppmV, a pressure-corrected volume fraction, so always confirm the unit and the reference pressure on a specification.
Good sample handling decides the quality of any moisture or dew-point reading. Use stainless steel tubing, keep lines short, avoid dead legs and filter out particles and liquids before the sensor. Plastic or rubber tubing absorbs and releases water vapour and slows the response, particularly at low dew points, and ambient moisture can enter through poorly made fittings, so check for leaks after commissioning.
Selection and compatibility notes for CD2PSS-AT-HW-MC
The order sheet lists ATEX and CSA versions and different supply voltages; CD2PSS-AT-HW-MC is the ATEX 230 VAC unit with ISO 18453 water calculation. Check that the certification and moisture calculation method suit your site before ordering.
Many Michell codes are built from a parent code followed by option letters. When you ask for a quotation for CD2PSS-AT-HW-MC, copy the complete code from the instrument label or from your purchase specification, including every letter after the parent code, and state the serial number if the unit replaces an installed one.
Before ordering, collect the data that avoids mistakes: the complete code and option letters, the serial number and year of any installed unit, the supply voltage, the hazardous-area certificate required by the site, the process pressure and temperature, the gas composition and the connection type. For spares from older installations, a photograph of the nameplate helps confirm the match, and it is useful to say whether the item replaces a failed device or is for a new installation.
Ask for the calibration certificate type your quality system needs, such as a traceable factory certificate or an accredited laboratory certificate where the manufacturer offers it, and keep it with the asset record so the next calibration date is visible during audits.
Installation and commissioning of CD2PSS-AT-HW-MC
Place the unit at the sample point, connect the sample and vent lines, set the flow within the stated range and use the touch-glass HMI described in the manual. An external junction box is needed for the outputs, as stated by the manufacturer.
Always read the current manufacturer manual before commissioning, check the hazardous-area certificate where one applies, verify the supply and signal wiring, and record the as-found settings so that the next service visit has a reference.
Gulf installations add heat, dust and humidity. Instruments mounted outdoors need shade or a suitable enclosure, cable glands that match the enclosure rating and sample lines that avoid condensation on cold desert nights. Compare the ambient temperature range in the table with the highest site temperature before choosing a mounting position.
Maintenance and calibration of CD2PSS-AT-HW-MC
Follow the manual for mirror cleaning, filter checks and calibration, and download the stored logs for review as required.
Moisture and dew-point measurements drift only slowly when the sample is clean, so most problems seen on installations of this kind come from contaminated sample lines, leaking fittings, wrong flow or damaged cables rather than from the instrument itself. A planned calibration interval agreed with your quality system keeps the measurement traceable.
Related products and ordering notes for CD2PSS-AT-HW-MC
The same manufacturer family includes sensors, transmitters, online hygrometers, chilled-mirror reference instruments, hydrocarbon dew-point analyzers, sampling systems and calibration equipment. Other Michell codes already listed on this site, such as the Easidew transmitters, the Promet EExd analyzer and the Condumax II, can be quoted together in a single RFQ.
CD2PSS-AT-HW-MC FAQ summary
Typical questions concern what the code means, which options apply and what to send with an enquiry. In short, it is a transportable hydrocarbon and water dew-point analyzer system with built-in sample system, and the figures in the table above come from the manufacturer documents. Questions that are not answered here can be sent with the RFQ.
Documents and quotation
The manufacturer datasheet for CD2PSS-AT-HW-MC is attached to this page where available. To request a quotation, send an RFQ with the part number CD2PSS-AT-HW-MC, the quantity and your delivery location in Oman or the GCC, and we will reply with availability and lead time.
Datasheets & Documents
- Datasheet Condumax II CD2PSS-AT-HW-MC Transportable Dew-Point Analyzer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the Condumax II CD2PSS-AT-HW-MC Transportable Dew-Point
Answers from our engineering team on installation, compatibility and integration.
01What is CD2PSS-AT-HW-MC?
CD2PSS-AT-HW-MC is a transportable hydrocarbon and water dew-point analyzer system with built-in sample system, as described in the manufacturer datasheet and order-code sheet.
02Is CD2PSS-AT-HW-MC portable by one person?
The datasheet gives a weight of about 60 kg, so it is transportable as a field system rather than hand-held; the CDP301 is the portable hand-carried tester.
03Does CD2PSS-AT-HW-MC measure water dew point?
Yes. It measures hydrocarbon and water dew point, with the water value calculated to ISO 18453 in this ATEX version.
04Can Seven Star LLC supply CD2PSS-AT-HW-MC in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for CD2PSS-AT-HW-MC?
Send the part number CD2PSS-AT-HW-MC, the quantity, the full option string or instrument serial number, any certificate needs and the delivery location so we can prepare an accurate quotation.