Metrohm 6.0258.010 Unitrode pH Electrode with Pt1000
Description
Overview
Where a titrator or meter needs both the pH signal and the sample temperature from one probe, the Metrohm 6.0258.010 is the electrode Metrohm lists for the job. It is a Unitrode with an integrated Pt1000 temperature sensor and a fixed cable of 1.2 m ending in a plug F for the pH signal and 2 mm banana plugs for the temperature sensor. Metrohm describes it as particularly suitable for pH measurements and titrations in difficult, viscous or alkaline samples at elevated temperatures, and for long-term measurements. Seven Star LLC is an independent supplier serving Oman and the GCC.
In practice this means one cable, one immersion, and automatic temperature compensation without a second sensor hanging in the beaker.
Specification of Metrohm 6.0258.010
| Characteristic | Metrohm data |
|---|---|
| Order number | Metrohm 6.0258.010, Unitrode with Pt1000 |
| Cable | Fixed, 1.2 m, plug F and 2 mm banana plugs |
| Temperature sensor | Pt1000, 2 mm connection |
| pH range | 0 to 14 |
| Temperature range | 0 to 80 degrees C long-term, 0 to 100 degrees C short-term |
| Membrane glass | Type U, cylinder |
| Membrane resistance | 150 to 500 MOhm |
| Electrode resistance | 5 kOhm |
| Zero point and slope | plus or minus 15 mV, above 0.97 |
| Diaphragm | Fixed ground joint |
| Reference electrolyte | KCl 3 mol/L, LL system |
| Flow rate | 5 to 30 microlitres per hour |
| Installation length | 113 mm maximum |
| Immersion depth | 25 mm minimum |
| Shaft | Glass, 12 mm |
Why a built-in Pt1000 helps
A pH electrode’s slope changes with temperature, and a titration that starts at 25 degrees C and warms during dosing will drift if the instrument assumes a fixed value. The Pt1000 inside the shaft of this electrode follows the actual temperature at the glass membrane, which keeps compensation accurate. The leaflet gives a specific wiring instruction: plug the B plugs of the built-in sensor into the temperature sockets of the pH meter, and if the meter has only one temperature socket, plug one of them into the reference electrode socket. Unconnected plugs of a temperature sensor can cause interfering signals, so never leave them dangling.
How Metrohm 6.0258.010 differs from its siblings
The 6.0259.100 has identical glass and diaphragm data, but a plug-in head and no temperature sensor. The Solitrode 6.0228.000 also has a Pt1000 and 1.2 m cable, but it uses a polypropylene shaft and glass type T with a ceramic diaphragm, and it is limited to 80 degrees C in all conditions. The 6.0233.100 is a plain combined electrode with no sensor. Select the Metrohm 6.0258.010 when samples are hot, viscous or alkaline and temperature must be measured with the same probe.
Long-term measurements
The data sheet text singles out long-term measurement as a use case. A fixed cable removes one potential leak point at the plug-in head, which is helpful when the electrode stays in a stirred tank, a sample loop or a rinse bath for days. For such use, check the electrolyte level at regular intervals because 5 to 30 microlitres per hour adds up to a noticeable volume over weeks.
Applications in Oman and the GCC
Hot alkaline process streams are common in desalination cleaning chemicals, power plant water chemistry and detergent or soap production. Oil and gas labs use pH titrations to check amine solutions and caustic washes, where temperatures are rarely close to 25 degrees C. The Unitrode with Pt1000 gives them reliable compensation without special calibration steps.
Electrolyte and storage choices
KCl at 3 mol/L is standard and the electrode is stored in Metrohm storage solution. For measurements above 80 degrees C, Metrohm names Idrolyte as the alternative electrolyte, and the electrode must then be stored in Idrolyte. Keep the diaphragm covered and never allow the electrode to dry out.
Connection and commissioning
Connect the plug F to the pH input and the two banana plugs to the temperature sockets of your meter or titrator. Verify the temperature reading against a calibrated thermometer, calibrate the pH function with two buffers, and store the slope result. Immerse at least 25 mm so that both membrane and diaphragm are covered by the sample.
Care and troubleshooting
Rinse after each use, do not use ultrasonic cleaning, and treat sulfide deposits with the thiourea solution mentioned in the Metrohm leaflet. Air bubbles in the electrolyte can be removed by flinging the electrode lightly downward. If the slope falls below about 96 percent, treat the diaphragm as the leaflet describes, and replace the electrode if no improvement follows. Because the cable is fixed, avoid tight bending and do not pull the electrode by its cable.
What the figures mean for method development
Titration methods for alkaline or viscous samples usually specify a stop criterion in millivolts or pH units and a dosing speed. A cylindrical type U membrane with a resistance of 150 to 500 megaohm tolerates the slower signal changes that arise in viscous media, so the dosing algorithm of the titrator can be set to wait for a stable potential without hunting. The zero point of plus or minus 15 mV and the slope above 0.97 define the quality of a new electrode, and any method validation report should list the slope found at commissioning so that later checks have a baseline.
The minimum immersion depth of 25 mm and the maximum installation length of 113 mm decide which beakers and stands fit. In a narrow sample vessel, check that the glass membrane, the diaphragm and the Pt1000 position are all below the liquid surface while the stirrer still has room to turn.
Handling the fixed cable
Route the 1.2 m cable so that it cannot be caught by the stirrer or the dosing tip, and keep the plugs clean and dry. Where the meter sits further away than the cable allows, use a Metrohm extension rather than strain the connection. Label both the pH plug and the temperature plugs on the instrument side if several electrodes share a bench, since a swapped temperature plug leads to an obviously wrong reading or an unstable one.
Related items you may also need: Metrohm 905 Titrando Potentiometric Titrator | Metrohm 916 Ti-Touch Compact Potentiometric Titrator | Metrohm 888 Titrando Potentiometric Titrator | All Metrohm products.
Metrohm 6.0258.010 ordering checklist
- When the Metrohm 6.0258.010 replaces an installed unit, check the existing nameplate against the code on this page before ordering.
- Every enquiry for the Metrohm 6.0258.010 is answered with a written confirmation of the code, condition and expected lead time.
- Use the attached datasheet to check the Metrohm 6.0258.010 ratings, dimensions and connection details against your drawings.
- We supply the Metrohm 6.0258.010 as part of our liquid analysis sensors range to plants in Oman and the GCC.
- For critical duty, keeping one Metrohm 6.0258.010 as a site spare shortens downtime after a failure.
Documents and quotation
The Metrohm leaflet on pH glass and gel electrodes is supplied with this page. Please send an RFQ with Metrohm 6.0258.010, the quantity and your delivery location in Oman or the GCC, and state the type of titrator or meter so the plug configuration can be confirmed.
Other Models in the PH Electrodes Range
Seven Star LLC supplies models from the PH Electrodes range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Metrohm 6.0233.100 Combined pH Glass Electrode SGJ 14/15 | Liquid Analysis Sensors | View details |
| Metrohm 6.0259.100 Unitrode Combined pH Electrode | Liquid Analysis Sensors | View details |
| Metrohm 6.0258.010 Unitrode pH Electrode with Pt1000 | Liquid Analysis Sensors | You are viewing this model |
Datasheets & Documents
- Datasheet Metrohm 6.0258.010 Unitrode pH Electrode with Pt1000 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Metrohm is a Swiss maker of instruments for chemical analysis, founded in 1943 by Bertold Suhner in Herisau, where it is still headquartered. It is best known for titration and also makes ion chromatography, electrochemistry, spectroscopy and process analysers. Metrohm is owned by a foundation.
Seven Star LLC lists the Metrohm 905 Titrando, the 916 Ti-Touch and the 2035 Process Analyzer, and supplies Metrohm instruments and accessories to laboratories and plants in Oman and the GCC.
Metrohm company profile
| Founded | 1943, Herisau, Switzerland |
|---|---|
| Founder | Bertold Suhner |
| Headquarters | Herisau, Switzerland |
| Ownership | Metrohm Foundation |
| Product families | Titrando and Ti-Touch titrators, ion chromatography systems, 2035 and 2060 process analysers, electrodes |
Metrohm instruments listed here
The 905 Titrando is a high-end potentiometric titrator for use with Dosino dosing units. It runs dynamic (DET), monotonic (MET) and set endpoint (SET) titrations, takes up to four 800 Dosino units, recognizes intelligent iTrode electrodes, and is operated from tiamo or OMNIS software or a Touch Control. The 2035 Process Analyzer is an online wet-chemistry analyzer for automatic analysis of samples drawn from the process.
Metrohm products we list
| Family | Examples |
|---|---|
| Liquid Analytical Systems | 2035 Process Analyzer, 905 Titrando Potentiometric Titrator, 916 Ti-Touch Compact Potentiometric Titr… |
Ordering Metrohm equipment: what we need
Metrohm article numbers follow a fixed pattern (the 905 Titrando is 2.905.0010), and that number is the best reference for instruments, electrodes and accessories. For a new application, tell us the sample, the parameter and its concentration range, the method or standard you follow, and for a process analyzer the number of sample streams and the signals your control system needs.
Facts checked against Metrohm's published company history, October 2026.
Browse Metrohm products by category: Liquid Analytical Systems.
FAQ
Questions about the Metrohm 6.0258.010 Unitrode pH Electrode with Pt1000
Answers from our engineering team on installation, compatibility and integration.
01What temperature sensor is built into the Metrohm 6.0258.010?
It contains an integrated Pt1000 sensor with 2 mm connectors, mounted in the shaft so that the sample temperature is measured at the electrode itself.
02How long is the cable on the Metrohm 6.0258.010?
The fixed cable is 1.2 m long and ends in a plug F for the pH signal plus 2 mm banana plugs for the temperature sensor.
03Can the Metrohm 6.0258.010 be used above 80 degrees C?
Short-term use up to 100 degrees C is listed; for measurements above 80 degrees C Metrohm suggests Idrolyte as reference electrolyte with storage in Idrolyte.
04How does the Metrohm 6.0258.010 differ from the 6.0259.100?
The glass, diaphragm and ranges are the same, but the 6.0258.010 has a fixed cable and Pt1000 while the 6.0259.100 has a plug-in head and no sensor.
05How should the temperature plugs of the Metrohm 6.0258.010 be connected?
The leaflet says to plug the B plugs into the temperature sockets of the meter, or one into the reference socket if only one temperature socket exists.