Brand: Kentec
Kentec Sigma CP K11040M2 4-Zone Conventional Fire Alarm Panel
Description
The Kentec Sigma CP K11040M2 is a four-zone, four-wire conventional fire alarm control panel from the Sigma CP range. The datasheet DS37 lists it with a 3 A power supply, two monitored sounder outputs and certification to BS EN54-2 and BS EN54-4. It is built on a single board and supplied in a 385 x 310 x 90 mm steel enclosure, so it suits small and medium premises that use conventional detectors, call points and sounders.
Product overview
Kentec positions the Sigma CP range for conventional fire detection and alarm systems, and as a replacement for panels on older systems. The range is available with two, four or eight zones, in standard four-wire or installation-saving two-wire versions. Configuration data is stored in non-volatile memory and is viewed and changed through a menu-driven user interface on the panel. The panels are compatible with most standard conventional detectors, call points and sounders, and with two-wire detector bases from Apollo and Hochiki.
Functions and configuration
- Fully certified to BS EN54-2 and BS EN54-4.
- Described as compatible for use on BS 5839 Part 1: 2017 installations.
- Two monitored sounder outputs, a three amp power supply and an auxiliary power output.
- Adjustable sounder delay time and sounder configuration options.
- Zonal sounder delay for detectors only or call points only, coincidence input selection and zone input delay.
- I.S. barrier selection by zone, short circuit fire by zone, non-latching zones and silent zones.
- Two-wire repeaters and ancillary boards on a serial connection.
Technical specification
Models in the range, from DS37 (K11040M2 is the four-zone, four-wire model without the LCMU):
| Product code | Description | LCMU | Standby current | Alarm current |
|---|---|---|---|---|
| K11020M2 | 2 zone, 4 wire | No | 0.065 A | 0.1 A |
| K11040M2 | 4 zone, 4 wire | No | 0.075 A | 0.21 A |
| K11080M2 | 8 zone, 4 wire | No | 0.093 A | 0.55 A |
| KL11020M2 / KL11040M2 / KL11080M2 | 2 / 4 / 8 zone, 4 wire | Yes | 0.065 / 0.075 / 0.093 A | 0.1 / 0.21 / 0.55 A |
| T11020M2 / T11040M2 / T11080M2 | 2 / 4 / 8 zone, 2 wire | N/A | 0.065 / 0.075 / 0.093 A | 0.15 / 0.3 / 0.63 A |
| Parameter | Specification |
|---|---|
| Size | 385 x 310 x 90 mm; weight 6 kg |
| Construction | 1.2 mm mild sheet steel, epoxy powder coated; IP30 |
| Supply voltage | 230 V AC (+10 percent / -15 percent); mains fuse 1.6 A 250 V |
| Power supply DC rating | 24 V, 3 A |
| Maximum battery size | 7 Ah 12 V, two per panel |
| Sounder output rating | 0.5 A per output, maximum 1.6 A over all outputs |
| Relay contact ratings | Fault, local fire and fire: 30 V DC, 1 A each |
| Detection zone current | 1.6 mA; end of line resistor 6k8 5 percent; optional active end of line K14606K |
| Sounder end of line | 10k 5 percent |
| Cable capacity | 2.5 mm2 per terminal |
| Operating temperature | -5 to +40 degrees C |
| Operating humidity | Below 95 percent, non-condensing |
| Optional accessory | K18002 tamper-resistant vision window |
Choosing a model
Choose the number of zones first, then four-wire (K) or two-wire (T) construction. The KL versions add the LCMU. K11040M2 is the standard four-wire panel with four zones and no LCMU. Repeater panels and ancillary boards for the same range are listed separately in datasheet DS39.
Installation notes
The datasheet specifies a detection zone end of line of 6k8 and a sounder end of line of 10k, and the manual Man-1078 covers wiring, configuration and operation of the panel. Because sounder outputs are rated 0.5 A each with a combined limit of 1.6 A, add up the connected sounder load before finalising the circuit design.
Typical applications
Small to medium commercial buildings, schools, hotels, workshops and warehouses where conventional zones are enough and a simple zone chart on the front fascia helps occupants and fire fighters.
Selection and installation notes
A fire alarm control panel is selected from the number of loops or zones, the devices to be connected, the standby battery duration and the standard the project requires. It must be designed, installed, programmed and commissioned by competent fire system engineers to the code and authority rules for the project, with a cause and effect plan, correct battery sizing, cable of the specified type and a full test of every device and output before handover. Confirm the certification needed for the project with the authority before purchase.
Conventional panels need the right end-of-line devices and cable on each zone, and the number of devices per zone must stay within the data sheet limits.
Information needed for a quotation
Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Documents and quotation
Both documents are available from this page. We supply from Muscat as an independent supplier, with no manufacturer relationship implied. See more in the fire alarm panels in the Logic Controllers category and ask for a quote with your zone count and wiring type.
Datasheets & Documents
Reviews (0)
How would you rate this product? Cancel reply
About brand
Kentec Electronics is a British manufacturer of fire alarm and extinguishant control panels, founded in 1985 in Kent and headquartered in Dartford. It began by assembling its first panel in a converted shed to give independent installers an alternative to the large manufacturers. Kentec exports to more than 80 countries and received the King's Award for Enterprise in International Trade in 2026.
Seven Star LLC is an independent supplier in Muscat. We list Kentec panels with the manufacturer datasheet and manual on each page, for fire alarm contractors and facilities in Oman and the GCC.
Kentec company profile
| Founded | 1985, Kent, England |
|---|---|
| Headquarters | Dartford, Kent |
| Exports | More than 80 countries |
| Approvals | EN 54 and UL/FM listed panels |
| Product families | Sigma conventional fire panels, Sigma XT and ZXT extinguishant release panels, Syncro AS addressable fire panels, Syncro XT+ extinguishant panels, UL864 panels, repeaters and marine panels |
Milestones
- 1985: Kentec builds its first panel in Kent.
- 2026: Kentec receives the King's Award for International Trade.
Kentec product series
Fire alarm panels include the Syncro AS two-loop addressable panel, the Syncro ASM marine version, the Sigma CP four-zone conventional panel with the Sigma CP-R repeater, and the UL864 listed Sigma A-CP conventional panel.
Extinguishant control panels include the Sigma XT+ four-zone two-area panel, the Syncro XT+, the single-area Sigma ZXT and the UL/FM Sigma A-XT releasing panel, and the Sigma Si is a six-lamp extinguishant status unit for doors of protected rooms. Datasheets state the standards by model, such as EN 54-2, EN 54-4, EN 12094-1 and UL864.
Where Kentec panels are used
Fire alarm systems in commercial and industrial buildings, and gas suppression release for server rooms, control rooms, switchgear rooms and archives, as well as marine installations.
Kentec products we list
Ordering Kentec panels: what we need
Send the Kentec part number, the number of loops or zones, the detector protocol for addressable panels, the extinguishing agent and number of areas for release panels, and the standard (EN or UL) required.
Facts checked against Kentec's catalogues and the 2026 King's Awards profile, October 2026.
Browse Kentec products by category: Logic Controllers.
Related products
Frequently Asked Questions
The datasheet states full certification to BS EN54-2 and BS EN54-4.
K is a four-wire panel without LCMU, KL is a four-wire panel with LCMU, and T is the two-wire version, per the DS37 table.
The maximum battery size is 7 Ah 12 V, with two batteries per panel.
0.5 A per output, with a maximum of 1.6 A over all outputs.
Yes. The range supports two-wire repeaters and ancillary boards; the repeater datasheet DS39 lists the Sigma CP-R.