Brand:

Festo VUVG-L14-M52-M-G18-P1 Solenoid Valve

Description

VUVG-L14-M52-M-G18-P1: 5/2-way, monostable solenoid valve, 14 mm wide

The Festo VUVG-L14-M52-M-G18-P1 (article 8033530) is a 5/2-way, monostable piloted solenoid valve of the piston-gate design with soft sealing. Seven Star LLC supplies VUVG-L14-M52-M-G18-P1 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer. This page summarises the datasheet values, how the valve is selected and what we need for a quotation.

What the datasheet states about this variant:

  • VUVG prefix: the 14 mm valve size with G-thread ports on the datasheet.
  • Valve function stated on the sheet: 5/2-way, monostable.
  • Working ports: G1/8; flow 700 l/min to 780 l/min (normalised to DIN 1343).
  • Pilot air supply: Internal.
  • Reset method: Mechanical spring.

VUVG-L14-M52-M-G18-P1 technical specifications

Data from the manufacturer data sheet for article 8033530.

Parameter Specification
Manufacturer / part number Festo / VUVG-L14-M52-M-G18-P1
Article number 8033530
Valve function 5/2-way, monostable
Valve size / width 14 mm
Normal nominal flow rate (DIN 1343) 700 l/min to 780 l/min
Nominal width 5.6 mm
Pneumatic working ports G1/8
Operating voltage via electric pilot valve
Operating pressure 3 to 8 bar
Pilot air supply port Internal
Degree of protection IP65, With electrical pilot valve and plug socket
Switching time on 12 ms
Switching time off / changeover 26 ms
Duty cycle 100%
Ambient and media temperature -5 °C to 60 °C
Electrical connection Via electric pilot valve
Mounting On terminal strip, With through-hole
Product weight 58 g
Housing material Wrought aluminum alloy
Seals material HNBR, NBR
Certification listed c UL us – recognized (OL)
Pilot interface As per ISO 15218

How the VUVG-L14-M52-M-G18-P1 works: pilot control and switching

In a 5/2 monostable valve one coil shifts the spool to one position and a mechanical spring or pneumatic spring returns it when power is removed, so the valve has one stable state. The valve is pilot-operated: the solenoid coil switches a small pilot stage and the pilot air then moves the main piston gate, which is why a coil rated about 1 W can control 700 l/min to 780 l/min of flow.

Pilot air is internal, with a pilot pressure window as stated in the table. Switching times of 12 ms on and 26 ms off or changeover set the upper limit for the cycle rate. Do not rely on the manual override for normal production; use it for commissioning and fault finding.

Where VUVG-L14-M52-M-G18-P1 fits: compatible and related parts

A valve like VUVG-L14-M52-M-G18-P1 drives one double-acting cylinder or actuator: ports 2 and 4 go to the two chambers, port 1 takes supply and 3 and 5 exhaust. Silencers or exhaust flow controls on 3 and 5 allow speed adjustment. Electrical plugs, coils and mounting or terminal strips are ordered as accessories according to the mounting options shown in the table.

Related valves handled by us include CPE14-M1BH-5LS-QS-6, CPE14-M1BH-5/3B-1/8, CPE14-M1BH-5J-1/8, VUVG-L14-M52-MT-G18-1H2L-F1A, VUVG-L14-P53E-T-G18-1R8L. They differ in valve function, flow, ports and approvals, so a replacement must be matched to the function and pressure range.

Selection and ordering checklist for VUVG-L14-M52-M-G18-P1

  • Function needed: 5/2-way, monostable.
  • Flow: 700 l/min to 780 l/min normal nominal flow, check it against actuator volume and speed.
  • Operating voltage: electric pilot valve voltage to be confirmed; permitted fluctuation as stated on the datasheet.
  • Pressure window 3 to 8 bar and pilot pressure as in the table.
  • Port type G1/8 and mounting method.
  • Ambient and media temperature: -5 °C to 60 °C.
  • The electrical connection is listed as via an electric pilot valve, so verify the pilot valve and plug side before assuming a direct 24 V coil connection.

Installation, commissioning and maintenance of VUVG-L14-M52-M-G18-P1

Mount the valve in any position using the through-hole or the terminal strip option listed; connect clean, dried air and keep ports 3 and 5 free to exhaust through silencers. Check the polarity and voltage of the coil plug and the degree of protection IP65 of the plug socket before powering.

At commissioning, actuate the valve with the manual override or a low pressure first, then set speed with flow controls on the cylinder. Common faults are low pilot pressure, dirty air that sticks the piston gate, and loose plugs. A spare coil or a spare valve is worth keeping for critical machines.

Typical applications of VUVG-L14-M52-M-G18-P1 in Oman and the GCC

Oman and the wider GCC put pneumatic equipment under demanding conditions: ambient heat in summer, fine desert dust, high humidity in coastal plants and compressed-air systems that are not always perfectly dried. This version is listed with a pilot interface as per ISO 15218 and its electrical connection is made via an electric pilot valve, with IP65 protection and a 26 ms off-switching time.

Valves of this size are usually found inside machine cabinets and on skid-mounted pneumatic panels, where the IP65 rating and the -5 °C to 60 °C ambient range are normally comfortable but should be checked in sun-exposed enclosures.

VUVG-L14-M52-M-G18-P1 compared with other solenoid valves in this range

Function, flow and ports of VUVG-L14-M52-M-G18-P1 against the other valves listed from datasheets.

Part number Function Flow (normal) Working ports
CPE14-M1BH-5LS-QS-6 5/2-way, monostable 400 l/min QS-6
CPE14-M1BH-5/3B-1/8 5/3-way, pressurized 750 l/min G1/8
CPE14-M1BH-5J-1/8 5/2-way, bistable 800 l/min G1/8
VUVG-L14-M52-MT-G18-1H2L-F1A 5/2-way, monostable 730 l/min G1/8
VUVG-L14-M52-M-G18-P1 5/2-way, monostable 700 l/min to 780 l/min G1/8
VUVG-L14-P53E-T-G18-1R8L 5/3 exhausted 560 l/min G1/8

Information to send with your VUVG-L14-M52-M-G18-P1 RFQ

  • Full part number VUVG-L14-M52-M-G18-P1 and quantity.
  • Supply voltage and whether a plug with cable or LED is needed.
  • Operating pressure and the actuator it will drive.
  • Fitting thread or tube size.
  • Mounting: single valve or on terminal strip.
  • Environment and delivery location in Oman or the GCC.

Documents and quotation

The manufacturer data sheet for VUVG-L14-M52-M-G18-P1 is attached on this page for download.

Send the part number VUVG-L14-M52-M-G18-P1 with quantity and delivery location and we will confirm availability and a quotation. Seven Star LLC is an independent supplier and is not affiliated with the manufacturer.

Other Models in the Festo Vuvg L14 Solenoid Valve Range

Seven Star LLC supplies models from the Festo Vuvg L14 Solenoid Valve range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Festo VUVG-L14-M52-MT-G18-1H2L-F1A Solenoid ValveSolenoid ValvesView details
Festo VUVG-L14-M52-M-G18-P1 Solenoid ValveSolenoid ValvesYou are viewing this model
Festo VUVG-L14-P53E-T-G18-1R8L Solenoid ValveSolenoid ValvesView details
Datasheets & Documents
  • PDF Datasheet Festo VUVG-L14-M52-M-G18-P1 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Festo is a German maker of pneumatic and electric automation technology, founded in 1925 in Esslingen am Neckar by Albert Fezer and Gottlieb Stoll; the name comes from their surnames. It first made woodworking machines and power tools before moving into pneumatics in the 1950s. Festo is family-owned and still headquartered in Esslingen.

Seven Star LLC sources and supplies Festo cylinders, valves and valve terminals for machine maintenance and projects in Oman and the GCC.

Festo company profile

Founded 1925, Esslingen am Neckar, Germany
Founders Albert Fezer and Gottlieb Stoll
Name From FEzer and STOll
Headquarters Esslingen am Neckar
Ownership Family-owned
Product families DSBC and ADN pneumatic cylinders, VUVG and VTUG solenoid valves and valve terminals, MS series air preparation units, CPX-AP remote I/O, EMMT servo motors and CMMT servo drives, electric axes and grippers

Milestones

  • 1925: Fezer and Stoll found the company in Esslingen.
  • 1950s: Festo begins making pneumatic components.

Festo products listed

Two items show the two halves of a pneumatic circuit. The VTUG is a valve terminal: a manifold that carries a row of directional valves with common air supply and a shared electrical connection. The DSBC-32-100-PPVA-N3 is an ISO standard cylinder. Its type code reads as 32 mm piston diameter and 100 mm stroke, with adjustable end-position cushioning and a piston magnet for position sensing.

Festo products we list

Family Examples
Automation Accessories KMP3-9P-08-5 Connecting Cable, KMPYE-AIF-1-GS-GD-2 Cable
Pneumatic Cylinders ADN-100-30-A-P-A Compact Cylinder
Valve Actuators DSBC-32-100-PPVA-N3 ISO Cylinder
Pressure Instrumentation VPEV-1/8 Pressure Switch
Solenoid Valves VTUG Valve Terminal

Ordering Festo parts: what we need

Festo parts carry both a type code and a numeric part number on the label. Send both when you can; the part number is the shortest route to an exact match. For a cylinder give the full type code as on the listed DSBC example, plus mounting parts and proximity switches if required. For a VTUG valve terminal send the configuration code or a label photo: number of valve positions, valve functions, coil voltage and the electrical connection type all vary from one terminal to the next.

Facts checked against Festo's corporate history pages, October 2026.

FAQ

Questions about the Festo VUVG-L14-M52-M-G18-P1 Solenoid Valve

Answers from our engineering team on installation, compatibility and integration.

01What does the VUVG-L14-M52-M-G18-P1 do?
It is a 5/2-way, monostable solenoid valve with G1/8 working ports and a normal nominal flow of 700 l/min...780 l/min according to the datasheet.
02What operating pressure does the VUVG-L14-M52-M-G18-P1 need?
The datasheet lists an operating pressure of 3 to 8 bar, with pilot air internal and a pilot pressure window as stated in the specification table.
03How fast does the VUVG-L14-M52-M-G18-P1 switch?
The datasheet gives 12 ms for switching on and 26 ms for switching off or changeover, which limits the achievable cycle rate.
04What electrical connection and protection does the VUVG-L14-M52-M-G18-P1 have?
Electrical connection: Via electric pilot valve. Degree of protection: IP65, With electrical pilot valve and plug socket.
05Can the VUVG-L14-M52-M-G18-P1 be used with vacuum or oil-lubricated air?
Operating medium is compressed air per ISO 8573-1:2010 [7:4:4]. Lubricated operation is possible but must then be continued. The datasheet states the valve is not suitable for vacuum.