Brand:

ION Science MiniPID 2 PPM WR Wide-Range PID Gas Sensor

Description

Overview

The ION Science MiniPID 2 PPM WR stretches the ppm-level PID further, to a range above 10,000 ppm, which equals more than one percent by volume of vapour. The datasheet gives a minimum detection limit of 500 ppb, a T90 response of less than 3 seconds and a sensitivity of more than 0.4 mV per ppm. Seven Star LLC is an independent supplier serving Oman and the GCC. It is the model that ION SENSE lists for LEL measurement, leak detection and repair, and EPA Method 21 work.

What a wide range allows

Fugitive emission programmes and refinery turnarounds produce readings that jump from background to tens of thousands of ppm at the surface of a leaking flange. A sensor that saturates at 4,000 ppm would report the same number for a small leak and a large one. With a range above 10,000 ppm the WR keeps reporting a meaningful figure, which is what an inspector needs to rank leaks and to check a repair. The price is a higher detection limit of 500 ppb and lower sensitivity, so it is not the sensor for ambient air quality.

Datasheet figures for ION Science MiniPID 2 PPM WR

Item Value
Electrode stack colour blue
Minimum detection limit 500 ppb
Range more than 10,000 ppm
T90 response time less than 3 seconds
Sensitivity more than 0.4 mV/ppm
Lamp-out diagnostic yes
Lamp 10.6 eV
Supply voltage, internal regulator 3.6 to 18 V (10 to 18 V when not intrinsically safe)
Supply voltage, regulated supply 3 to 3.6 V
Current 20 to 32 mA, 130 mA for 100 ms at start-up
Power consumption 100 mW at 3.3 V
Output signal 0 to rail voltage minus 0.1 V
Temperature range minus 40 to plus 65 degrees C
Humidity range 0 to 99 percent RH, non-condensing
Sensor body life more than 5 years
Lamp life 10,000 hours
Package Series 4/A
Order codes MP3SWMLLAU2 (3.0 to 3.2 V), MP3SWMLLBU2 (3.2 to 3.6 V), MP3SWMLLCU2 (3.6 to 10.0 V), MP3SWMLLNU2 (3.6 to 18 V)
Hazardous area approvals ATEX II 1G Ex ia IIC Ga and IECEx Ex ia IIC Ga, minus 40 to plus 55 degrees C ambient at 1.1 W; UL913 Class I, II, III Division 1; EAC

Use of the ION Science MiniPID 2 PPM WR in leak programmes

  • LEL measurement
  • Leak detection and repair, usually shortened to LDAR
  • EPA Method 21 style screening of equipment components
  • Process control
  • Industrial health and safety and confined space entry

Refineries, gas plants and tank terminals in Oman and the GCC run LDAR programmes to reduce losses and meet environmental rules. An instrument built around this sensor can screen thousands of components per shift. The 3-second T90 makes it practical to hold the probe at each seal only briefly before moving on.

How MiniPID 2 PPM WR differs from the PPM sensor

The PPM and the PPM WR share the housing, the blue stack and the response time. The PPM reads from 100 ppb up to above 4,000 ppm with sensitivity above 0.65 mV per ppm at 100 ppm, while the WR reads from 500 ppb up to above 10,000 ppm with more than 0.4 mV per ppm. A design that must find small leaks and also measure large ones will normally choose the WR, while one that works at low ppm only will give better resolution with the PPM. Neither has the sub-ppb capability of the PPB or HS sensors.

Electrical data

Supply is 3.6 to 18 V through the internal regulator, 10 to 18 V if the part is not used in an intrinsically safe circuit, or 3 to 3.6 V on a regulated rail. Current is 20 to 32 mA with a 130 mA start-up peak lasting 100 ms; power consumption is 100 mW at 3.3 V; output is a voltage reaching the rail minus 0.1 V. Operating range is minus 40 to plus 65 degrees C and 0 to 99 percent relative humidity without condensation. The approvals are ATEX II 1G Ex ia IIC Ga, IECEx, UL913 Class I, II, III Division 1 and Eurasian customs certification.

Calibration and response factors

Calibrate on isobutylene at a concentration well above the lowest alarm point, for instance 500 or 1,000 ppm, and check a second point near the top of the range. Because the output is linear only approximately over such a wide span, a multi-point correction improves accuracy. Response factors for the compounds you screen, such as hexane, toluene or propylene, convert the isobutylene scale to real concentration. ION PC software, used with the ION CONNECT kit, stores these factors and alarm thresholds.

Selecting the sensor for LDAR

Check the leak definition used by your programme. Many regimes define a leak at a few hundred or a thousand ppm above background, and others at ten thousand ppm. If the threshold is 500 ppm or lower, the PPM version has the better resolution; if the programme includes a 10,000 ppm definition, or if repaired components must be shown to fall below an upper limit, the WR is the one whose range reaches it. Also review the response factor of the dominant process vapour, because compounds with a poor PID response, such as methane or ethane, will not be seen at all by a 10.6 eV lamp.

Care of the sensor

High concentrations load the lamp window and chamber with deposits faster than trace work does, so plan cleaning more often than for the PPB family. Keep a spare electrode stack and lamp in the field kit. After exposure to very high concentrations, allow the sensor to clear in clean air before taking another reading. The warranty on the 10.6 eV lamp and sensor body is 12 months according to the datasheet.

Integration kits

ION CONNECT with UART and I2C gives quick access to data, and ION TRANSMIT supplies RS-485 Modbus RTU and 4 to 20 mA outputs for fixed installations. The ION GAS HOOD is available where impressed flow is needed.

Related items you may also need: ION Science Tiger XT Handheld VOC Detector | ION Science Titan 2 Fixed Benzene Monitor | General Monitors FL4000H Multi-Spectrum IR Flame Detector | All ION Science products.

ION Science MiniPID 2 PPM WR ordering checklist

  • When the ION Science MiniPID 2 PPM WR replaces an installed unit, check the existing nameplate against the code on this page before ordering.
  • Every enquiry for the ION Science MiniPID 2 PPM WR is answered with a written confirmation of the code and expected lead time.
  • Use the attached datasheet to check the ION Science MiniPID 2 PPM WR ratings, dimensions and connection details against your drawings.
  • We supply the ION Science MiniPID 2 PPM WR as part of our fire & gas detectors range to plants in Oman and the GCC.
  • For critical duty, keeping one ION Science MiniPID 2 PPM WR as a site spare shortens downtime after a failure.

Documents and quotation

The ION Science MiniPID 2 PPM WR datasheet from the manufacturer lists the specifications and order codes. We include the sensor datasheet with this page; it shows the drawings and the order codes. Send your RFQ stating the model, the order code that matches your supply voltage, the quantity, and your delivery location in Oman or the GCC.

Other Models in the MiniPID2 Range

Seven Star LLC supplies models from the MiniPID2 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
ION Science MiniPID 2 PPB VOC PID Gas SensorFire & Gas DetectorsView details
ION Science MiniPID 2 PPB WR Wide-Range PID Gas SensorFire & Gas DetectorsView details
ION Science MiniPID 2 PPB XF Long-Life PID Gas SensorFire & Gas DetectorsView details
ION Science MiniPID 2 HS High-Sensitivity PID Gas SensorFire & Gas DetectorsView details
ION Science MiniPID 2 10.0 eV BTEX Benzene PID Gas SensorFire & Gas DetectorsView details
ION Science MiniPID 2 11.7 eV High-Energy PID Gas SensorFire & Gas DetectorsView details
ION Science MiniPID 2 PPM Fast-Response PID Gas SensorFire & Gas DetectorsView details
ION Science MiniPID 2 PPM WR Wide-Range PID Gas SensorFire & Gas DetectorsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet ION Science MiniPID 2 PPM WR Wide-Range PID Gas Sensor Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ION Science is a British maker of gas detection instruments, based in Fowlmere, Cambridgeshire. It has been active since 1989 and is best known for photoionisation detectors (PIDs) that measure volatile organic compounds at low concentrations. Its portable and fixed instruments are used for worker exposure monitoring, leak detection and environmental surveys.

Seven Star LLC is an independent supplier in Muscat. We list ION Science detectors for oil and gas, petrochemical and environmental users in Oman and the GCC.

ION Science company profile

Active since 1989, United Kingdom
Head office Fowlmere, Cambridgeshire
Core technology Photoionisation detection (PID) with patented Fence Electrode design
Product families Tiger XT and Cub portable PIDs, Titan benzene monitor, Falco fixed detectors

Milestones

  • 1989: ION Science begins operating.
  • 1998: Patents its PID sensor.
  • 2002: Patents the Fence Electrode for humidity-resistant PIDs.
  • 2017: Opens its head office in Fowlmere.

ION Science product series

The Tiger XT is a handheld VOC detector for hazardous areas, and the Titan 2 is a fixed benzene monitor.

A PID uses ultraviolet light to ionise volatile organic compounds and measures the resulting current, which allows detection down to ppb levels. Response factors convert the reading for each specific compound. General VOC detectors measure the total, while benzene-specific monitors separate benzene from other hydrocarbons, which matters because benzene has very low exposure limits.

Where ION Science detectors are used

Leak detection, confined space entry checks, worker exposure monitoring, refinery and terminal benzene monitoring, and environmental and soil surveys.

Ordering ION Science detectors: what we need

Send the model, the compounds and ranges, lamp type, hazardous-area requirement and accessories such as probes, filters and calibration kits.

Facts checked against ION Science's published company history, October 2026.

FAQ

Questions about the ION Science MiniPID 2 PPM WR Wide-Range PID Gas

Answers from our engineering team on installation, compatibility and integration.

01What is the range of the ION Science MiniPID 2 PPM WR?
The datasheet gives a range above 10,000 ppm with a minimum detection limit of 500 ppb and sensitivity above 0.4 mV per ppm.
02What applications does the PPM WR target?
LEL measurement, leak detection and repair, EPA Method 21, process control, industrial health and safety and confined space entry are listed.
03Which order codes exist for the MiniPID 2 PPM WR?
MP3SWMLLAU2, MP3SWMLLBU2, MP3SWMLLCU2 and MP3SWMLLNU2, covering 3.0 to 18 V intrinsically safe supply windows.
04How is the PPM WR different from the PPM?
The WR reaches above 10,000 ppm but starts at 500 ppb, whereas the PPM covers 100 ppb to above 4,000 ppm with higher sensitivity.
05How fast does the MiniPID 2 PPM WR respond?
T90 response time is less than 3 seconds, which suits quick screening of equipment components.