Brand:

KRACHT SD 1 I 24 / V Volume Display with 4-20 mA Output

Description

Volume on the display, current on the wire: SD 1 I 24 / V

KRACHT SD 1 I 24 / V is a plug-on SD 1 display that does two things at once: it shows accumulated volume on its LED display and it converts the reading to a flow- or volume-proportional current of 0 to 20 mA or 4 to 20 mA. It slides between plug and base of a KRACHT volume counter with a DIN 43650 connection.

The slash V at the end of the code selects volume measurement; I selects the current output; 24 means 24 VDC. In this version no square-wave signals are output, so the control system must read the current loop instead of counting pulses.

Technical data of SD 1 I 24 / V

Parameter Value
Type code SD 1 I 24 / V
Output signal Current, 0 to 20 mA or 4 to 20 mA; apparent resistance up to 250 ohm at 18 to 28 VDC supply, up to 50 ohm at 10 VDC; 10 bit resolution; short-circuit proof
Display function Volume (summing, sum release on a pin)
Supply voltage 24 VDC (18 to 28 VDC; optional 10 to 19 VDC)
Maximum power consumption approx. 120 mA
Display 7-segment LED, 7.62 mm, red, 0.000 to 9999 floating point
Overflow above 9999 the display shows 9999
Keyboard two buttons behind the front panel
Housing Aluminium
Dimensions height without plug approx. 35 mm, width approx. 60 mm, depth approx. 60 mm
Weight approx. 0.12 kg
Connection Angle plug DIN 43650, 4-pin, reverse polarity protected
Protection IP 65 (DIN 40050)
Operating temperature 0 to 60 C
Storage temperature -25 to 85 C
Memory settings stored in EEPROM, kept after power failure

Reading the volume output of SD 1 I 24 / V

Volume measurement means the instrument totals the pulses and shows the quantity delivered, for example the litres passed during a batch. The datasheet notes that in the volume version the sum clearance, that is the release of summing, is on a pin of the connector, so a controller can start and stop the totalising.

Terminal use for the current version: pin 1 supply of 12/24 VDC, pin 2 ground and pin 3 the 0 or 4 to 20 mA output. The load must stay under 250 ohm at the normal 18 to 28 VDC supply.

How SD 1 I 24 / V differs from the R and K versions

Against SD 1 R 24, this code trades the square-wave pulses for a current output and shows volume instead of flow. Against a relay version K, which supplies two programmable contacts at 24 VDC / 1 A for limit alarms, the I code offers a continuous value. Choose current when a PLC analogue card or chart recorder is the receiver, and relays when only limit switching is needed.

A 10 bit resolution of the current output means roughly 1,024 steps across the range, adequate for trending and display on a SCADA screen.

Where SD 1 I 24 / V is used

A plant that already has analogue inputs on its PLC but no pulse counter card benefits from this version: the volume counter on the lube oil line stays unchanged, the SD 1 adds a local display and an analogue signal that the existing PLC can read. Typical examples are hydraulic power packs and lubrication systems on compressors and gearboxes.

Gulf maintenance teams also use the display to avoid walking to the control room to check totals during oil changes.

For example, a lubrication system on a gas compressor needs to log oil consumption per shift. The SD 1 shows the running total at the machine, and the 4 to 20 mA signal feeds the plant historian through an existing analogue card. A technician can compare the local display and the SCADA trend and see at once if the loop is out of calibration.

Another example is a mobile test rig that is moved between sites. The display is on the meter, the current signal goes to a portable data logger, and nothing needs to be rewired between sites other than the supply.

Compatibility and selection

The unit is for KRACHT volume counters with a DIN 43650 plug. The supply of 18 to 28 VDC (optionally 10 to 19 VDC) comes from the machine. Check the load on the analogue output against the supply used. Programming of the pulse volume is done with two buttons behind the front panel, and the settings are stored in EEPROM.

A current loop is robust against electrical noise over long cables, which matters in plants with large motors and frequency converters. For loop powering, note that this unit is supplied separately at 18 to 28 VDC and drives the output itself, so it is an active output, not a two-wire loop-powered transmitter.

Fitting and set-up of SD 1 I 24 / V

Open the existing plug, remove the amplifier board, mount the display, program the pulse volume and the output span, and compare the output current with the reading at known volume increments. Use shielded cable for the current loop.

Record the span you programmed (for example 4 mA at zero volume rate and 20 mA at the maximum) in the commissioning file. When the display is replaced later, that record saves time and avoids mismatched scaling in the PLC.

Maintenance and notes

No routine service is required. Check the loop calibration with a milliammeter at planned intervals and keep the angle plug sealed to retain IP 65.

Ordering and related units

Quote SD 1 I 24 / V in full because the suffix V and the output letter matter. Related: SD 1 R 24, AS 8 U 230 DOS / F and AS 8 U 24 D2F / F.

Documents and quotation

The datasheet is attached to this page. Send an RFQ for SD 1 I 24 / V with quantity to Seven Star LLC, an independent supplier serving Oman and the GCC and not affiliated with the manufacturer.

Selection Notes for the KRACHT SD 1 I 24 / V

When comparing the KRACHT SD 1 I 24 / V with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the KRACHT flow computers range and confirm the correct order code before you commit.

Other Models in the Kracht As8 Electronics Range

Seven Star LLC supplies models from the Kracht As8 Electronics range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
KRACHT AS 8 I 24 ZM / F Cylinder Stroke Measuring UnitFlow ComputersView details
KRACHT AS 8 U 230 DOS / F Dosing Controller 230 VFlow ComputersView details
KRACHT AS 8 I 24 RP Flow and Speed Controller 24 VDCFlow ComputersView details
KRACHT AS 8 U 24 D2F / F Flow Difference DisplayFlow ComputersView details
KRACHT AS 8 U 230 PUR / F Mixing Ratio ControllerFlow ComputersView details
KRACHT SD 1 R 24 Plug-On Flow Display Square-Wave OutputFlow ComputersView details
KRACHT SD 1 I 24 / V Volume Display with 4-20 mA OutputFlow ComputersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet KRACHT SD 1 I 24 / V Volume Display with 4-20 mA Output Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.

Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.

KRACHT company profile

Founded 1911, registered as Hillebrand & Kracht OHG
Headquarters Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971
Ownership Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company
Size About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco
Subsidiaries USA, China and Hungary (KRACHT Hidraulik Kft.)
Product families External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders

Milestones

  • 1911: Hillebrand & Kracht OHG is entered in the trade register.
  • 1971: The company moves into its present premises in Werdohl.
  • 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
  • 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.

KRACHT pumps, flow meters and valves listed

The listing follows four product groups, pumps, fluid measurement, valves and drives:

  • Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
  • Fluid measurement technology: gear type flow meters such as the VCA in aluminum
  • Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
  • Drive technology: KM hydraulic gear motors

Where KRACHT equipment is used

KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.

KRACHT products we list

Family Examples
Pumps BT / BTH Low-Speed Gear Pump, DT DuroTec Gear Pump for Abrasive Fluids, KD1 Gear Metering Pump, KF 0 Stainless Steel Process Gear Pump, KF Series Modular Gear Pump, KF-F Fuel Gear Pump Series, KF80RF2-D15 Gear Pump, KM Series Hydraulic Gear Motor and 2 more
Flowmeters Fluid Measurement Technology Series, SVC Screw Type Flow Meter, TM Turbine Flow Meter, VC 0.01 Micro Gear Type Flow Meter, VC Gear Type Flow Meter, VCA Aluminum Gear Flow Meter, VCM Gear Flow Meter
Safety Relief Valves DBD Directly Controlled Poppet Valve, DV B Hydraulically Pilot Controlled Valve, HV/HVF Pilot Operated Slide Valve, SPV 10 L1G 1 A 12 Pressure Relief Valve, SPV/SPVF Directly Controlled Slide Valve, Valve Technology Series
Hydraulic Valves & Components CNL Hydraulic Cylinder, DV S Pressure Stage Control Valve
Gear Units & Reducers Drive Technology Series

Ordering KRACHT parts: what we need

KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.

Frequently requested KRACHT models: KRACHT Pump Technology Series.

Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.

FAQ

Questions about the KRACHT SD 1 I 24 / V Volume Display with 4-20 mA

Answers from our engineering team on installation, compatibility and integration.

01What does the V in KRACHT SD 1 I 24 / V mean?
V selects volume measurement; without it the SD 1 displays flow.
02What output does SD 1 I 24 / V have?
A current output of 0 to 20 mA or 4 to 20 mA proportional to the measured value, with 10 bit resolution and short-circuit protection.
03What load can SD 1 I 24 / V drive?
Up to 250 ohm at 18 to 28 VDC supply and up to 50 ohm at 10 VDC supply.
04Does SD 1 I 24 / V still output square-wave pulses?
No, with the current output the square-wave signals are not available.
05Which meters can SD 1 I 24 / V be fitted to?
KRACHT volume counters with a plug connection in accordance with DIN 43650.