Brand:

Yokogawa EJX510A-JCS4N-012DN Absolute Pressure Transmitter

Description

Yokogawa EJX510A-JCS4N-012DN: what it measures and how

Yokogawa EJX510A-JCS4N-012DN is a DPharp EJX-series absolute pressure transmitter. Its silicon resonant sensor reads pressure against a vacuum reference, so the result is not affected by barometric change. The C capsule spans 0.1 to 10 MPa absolute with a reference accuracy of plus or minus 0.04 percent of span for spans of 1 MPa and above, which is tighter than the 0.055 percent of the EJA-E sibling. Output is 4 to 20 mA with HART 5 or HART 7, a digital indicator sits under the cover glass, and the process port is a 1/2 NPT female thread.

Reading the suffix JCS4N-012DN

Code position Meaning
-J 4 to 20 mA DC with HART 5 or HART 7 digital communication (selected at ordering)
C Capsule: span 0.1 to 10 MPa
S 316L SST process connector, Hastelloy C-276 diaphragm, 316L SST or F316L SST other wetted parts
4 Process connection: 1/2 NPT female
1 Amplifier housing: cast aluminum alloy
2 Electrical: 1/2 NPT female, two electrical connections, no blind plugs
D Integral indicator: digital indicator
N Mounting bracket: none

What EJX adds: stability and diagnostics

The EJX datasheet quotes stability for fifteen years: plus or minus 0.2 percent of URL for the EJX510A. That is a longer period than the ten years quoted for the EJA-E range. Optional code DG6 adds multi-sensing process monitoring for HART versions: impulse-line blockage detection by extracting the fluctuation component from the static pressure signal, and heat-trace monitoring based on two temperature sensors built into the transmitter. Because EJX510A-JCS4N-012DN is an absolute-pressure in-line unit with no impulse lines, these diagnostics serve mainly the differential versions, but the platform is common to the series. A status-output option AL gives a sink transistor output rated 30 V DC and 120 mA.

Specification sheet for EJX510A-JCS4N-012DN

Item Value
Capsule C Span 0.1 to 10 MPa abs; URL 10 MPa abs
Reference accuracy Plus or minus 0.04 percent of span (span 1 MPa or larger)
Stability Plus or minus 0.2 percent URL for 15 years
Over-pressure 20 MPa abs
Burst pressure 30 MPa
Response time 90 ms
Update period 45 ms
Output 4 to 20 mA, HART 5/7
Supply 10.5 to 42 V DC
Process temperature Minus 40 to 120 degrees C
Ambient Minus 40 to 85 degrees C; minus 30 to 80 degrees C with LCD
Weight 1.2 kg without indicator or bracket

Indicator and local operation on EJX510A-JCS4N-012DN

The digital indicator under the cover glass has a five-digit numeric display, a six-digit unit field and a bar graph. It can show pressure in percent, scaled pressure and measured pressure in rotation. Indicator code D has no push button; code E adds the range-setting switch so that LRV and URV can be pressed in from actual process pressure. The external zero screw adjusts continuously with 0.01 percent resolution of span in both cases. Fitting the LCD narrows the ambient lower limit to minus 30 degrees C and the upper limit to 80 degrees C, so for very hot outdoor sites in the Gulf where the case may exceed that in direct sun, a shade or a sun shield is advisable.

Application fit

The C capsule window serves compressor and turbine auxiliaries, steam headers up to 10 MPa abs, and gas supply to burners. A fixed vacuum reference is valuable in hot, sandy Gulf conditions where weather changes would otherwise show up as a few kPa of drift in gauge instruments. The LCD helps field operators confirm reading without a handheld during rounds.

Pick J when the host supports HART 7 or HART 5; E is HART 5 only; D is BRAIN. Choose the capsule based on process maximum: A for up to 200 kPa abs, B up to 2 MPa abs, C up to 10 MPa abs, D up to 50 MPa abs. Select the thread to match the tapping, here 1/2 NPT female.

Mounting EJX510A-JCS4N-012DN

The unit has no bracket, since the last character is N. Mount it directly on rigid piping or on a stand. Keep the process thread sealed, seal the unused conduit entry and reach the zero-adjust screw from the cover side. At 1.2 kg the transmitter can hang on a 1/2 inch pipe stub, but vibration should be limited; the datasheet gives test levels for the housing.

Check zero at shutdown against vacuum, review diagnostics through a HART host and keep covers tightened. Clean the LCD window with a damp cloth only.

Related codes and ordering notes for EJX510A-JCS4N-012DN

The EJX510A family shares one datasheet, so EJX510A-JCS4N-012DN differs from its siblings only in single suffix positions. Capsule A moves down to an 8 to 200 kPa abs span, B covers 0.02 to 2 MPa abs, and D reaches 50 MPa abs with a 75 MPa abs over-pressure rating. Output code D uses BRAIN, E selects HART 5 and J allows HART 5 or 7. The gauge-pressure twin is the EJX530A, which takes the same suffix structure but measures against atmosphere and quotes a better stability of 0.1 percent of URL over fifteen years. Option codes after the slash, such as /A for a lightning protector, /AL for a status output, /DG6 for advanced diagnostics, /HAC and /C2 for NAMUR limits, each create a different quotation, so mention any of them that appear on your nameplate.

Because the base code here ends with N for the bracket, plan a separate 2-inch bracket if the unit will go onto a pipe stand.

Quick answers about EJX510A-JCS4N-012DN

  • How accurate is EJX510A-JCS4N-012DN? Reference accuracy is plus or minus 0.04 percent of span for spans of 1 MPa and above for the C capsule, per the datasheet.
  • What is the pressure span for the C capsule? 0.1 to 10 MPa absolute, which is 14.5 to 1450 psi.
  • Is there an indicator on EJX510A-JCS4N-012DN? Yes. D in the ninth suffix position is a digital indicator.
  • How long is the stability specification valid? Stability is plus or minus 0.2 percent of URL for 15 years for the EJX510A.
  • Can this model detect a blocked impulse line? The DG6 option exists for the series, but this part number is quoted without options and has no impulse lines.

Documents and quotation

Include the nameplate suffix exactly as shown.

The Yokogawa general specification GS 01C25F01-01EN, which covers the EJX510A and EJX530A, is supplied as the datasheet PDF with this listing. To request a quotation, send the part number EJX510A-JCS4N-012DN, the quantity, tag numbers, process fluid and the approval you need if the area is classified. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Availability and lead time are confirmed per RFQ.

Datasheets & Documents
  • PDF Datasheet Yokogawa EJX510A-JCS4N-012DN Absolute Pressure Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa EJX510A-JCS4N-012DN Absolute Pressure

Answers from our engineering team on installation, compatibility and integration.

01How accurate is EJX510A-JCS4N-012DN?
Reference accuracy is plus or minus 0.04 percent of span for spans of 1 MPa and above for the C capsule, per the datasheet.
02What is the pressure span for the C capsule?
0.1 to 10 MPa absolute, which is 14.5 to 1450 psi.
03Is there an indicator on EJX510A-JCS4N-012DN?
Yes. D in the ninth suffix position is a digital indicator.
04How long is the stability specification valid?
Stability is plus or minus 0.2 percent of URL for 15 years for the EJX510A.
05Can this model detect a blocked impulse line?