- Automation & ControlView all 2,947 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Yokogawa
Yokogawa EJA510E-JCS7N-012DN Absolute Pressure with LCD
Description
Why EJA510E-JCS7N-012DN suits a male-threaded tapping
Not every process tapping is a female thread. Yokogawa EJA510E-JCS7N-012DN carries a 1/2 NPT male connection, so it screws straight into a female coupling or a threaded boss on a vessel, a manifold block or a compressor discharge fitting without a nipple. The transmitter measures absolute pressure with the C capsule across a span of 0.1 to 10 MPa abs, and an integral digital indicator is already fitted, so an operator can read pressure at the field location without a handheld.
The output is 4 to 20 mA with HART. Everything else in the suffix is the common stainless and aluminum build, so replacement stock is straightforward.
Breaking down the JCS7N-012DN code
| Code position | Meaning |
|---|---|
| -J | 4 to 20 mA DC with HART 5 or HART 7 digital communication (selected at ordering) |
| C | Capsule: span 0.1 to 10 MPa |
| S | 316L SST process connector, Hastelloy C-276 diaphragm, 316L SST or F316L SST other wetted parts |
| 7 | Process connection: 1/2 NPT male |
| 1 | Amplifier housing: cast aluminum alloy |
| 2 | Electrical: 1/2 NPT female, two electrical connections, no blind plugs |
| D | Integral indicator: digital indicator |
| N | Mounting bracket: none |
What the C capsule gives you
Where the B capsule stops at 2 MPa abs, the C capsule covers 0.1 to 10 MPa abs. Maximum working pressure is 10 MPa abs and over-pressure is 20 MPa abs; burst pressure is quoted as 30 MPa. Accuracy is plus or minus 0.055 percent of span at spans of 1 MPa or larger. Ten-year stability for the EJA510E is plus or minus 0.2 percent of URL. The ambient temperature effect is the same plus or minus (0.15 percent span plus 0.15 percent URL) per 28 degrees C seen in the A and B capsules, so large spans are the better use of the C capsule.
Process fluids and materials for EJA510E-JCS7N-012DN
The S wetted-parts code means a 316L stainless process connector and a Hastelloy C-276 diaphragm, with 316L or F316L stainless elsewhere. The datasheet marks these materials as conforming to NACE MR0175 and ISO 15156 recommendations, and states that they also conform to MR0103. Silicone oil is the standard fill fluid, and a fluorinated oil capsule is an optional code. The datasheet cautions that wetted-material selection is the buyer responsibility, particularly for hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite and steam at 150 degrees C or more. For EJA510E-JCS7N-012DN, the process temperature limit is minus 40 to 120 degrees C.
Key facts about EJA510E-JCS7N-012DN at a glance
| Parameter | Data |
|---|---|
| Capsule C span | 0.1 to 10 MPa abs |
| URL / MWP | 10 MPa abs |
| Over-pressure | 20 MPa abs |
| Output | 4 to 20 mA, HART 5 or 7 |
| Process connection | 1/2 NPT male |
| Wetted material | 316L SST with Hastelloy C-276 diaphragm |
| Integral indicator | Digital LCD, up to three variables shown periodically |
| Ambient limit | Minus 30 to 80 degrees C with LCD |
| Housing code | 1, cast aluminum, IP66/IP67 |
| Electrical | 1/2 NPT female x2 |
| Response | 90 ms |
| Weight | About 1.2 kg before options |
Applications for a C capsule absolute transmitter
The C capsule matches the pressure level of compressed-air headers, high-pressure steam let-down, hydraulic power units and gas gathering lines. In Gulf plants it often shows up on reciprocating-compressor stages, fuel gas conditioning skids, and pump discharge on water injection, wherever site ambient pressure variation would be unwelcome in the measurement. The integral display saves a technician a trip to the control room when verifying a pressure switch setpoint.
EJA510E-JCS7N-012DN compared with sibling codes
Compared with the 1/2 NPT female option, the male thread removes one adapter and one leak path but demands a female counterpart on the tapping. Compared with the plain NN version, adding the D indicator costs nothing in wetted construction and the LCD lowers the allowed ambient range to minus 30 degrees C at the cold end. If you need push-button re-ranging at the device, the indicator code E, not D, is the one that includes the range-setting switch.
Fitting and wiring EJA510E-JCS7N-012DN
Tighten the male thread into the coupling by wrench on the process connector flats only, never by twisting the housing. Rotate the housing and the indicator to a readable angle before commissioning. Use the two 1/2 NPT conduit entries for power and, if required, a loop-powered relay; plug the unused entry. HART communication needs at least 250 ohm of load and minimum 16.6 V at the terminals, so check the supply and barrier voltage drop before final wiring.
Look for moisture inside the terminal compartment at each inspection, confirm that the display units match the loop sheet and review the self-diagnostic alarms stored in the device. Because the transmitter is vacuum-referenced, a zero check should be done with the connection vented to vacuum, not simply open to atmosphere.
The same transmitter family offers more than EJA510E-JCS7N-012DN. If you are replacing a damaged unit and the nameplate reads differently, say so in the inquiry: an A or B capsule needs the lower pressure window, a gauge-pressure EJA530E replaces an absolute unit only when vacuum reference is not needed, and the HART option is not interchangeable with BRAIN without checking the host. Optional codes after the slash, for instance degreasing for oxygen service, fluorinated oil fill or gold-plated diaphragm for hydrogen service, change the product and must be quoted explicitly. The datasheet lists these options in detail, and EJA510E-JCS7N-012DN is quoted without them unless you request otherwise.
Many maintenance teams also keep a 2-inch pipe bracket in stock, since this specific code was ordered with the bracket field set to N.
Quick answers about EJA510E-JCS7N-012DN
- What is different between this and EJA510E-JBS4N-012NN? This one uses the C capsule, a 1/2 NPT male connection and an integral digital indicator; the other uses the B capsule, a female connection and no indicator.
- Can the LCD of EJA510E-JCS7N-012DN be used to re-range? The D indicator only displays. Local re-ranging by push button needs indicator code E, which includes the range-setting switch.
- What pressure can the C capsule survive? Over-pressure is 20 MPa abs and burst pressure is 30 MPa according to the datasheet. Continuous working pressure is limited to 10 MPa abs.
- How is the 1/2 NPT male thread sealed? Use a thread sealant suitable for the process fluid and tighten on the connector flats. The datasheet only specifies the thread type.
- Does this model hold SIL 2? The EJA-E series in standard HART configuration is certified SIL 2 capable for single use and SIL 3 for dual transmitters, per the datasheet.
Documents and quotation
If you hold a data sheet from the plant, send us the tag number as well so we can match the suffix exactly.
The manufacturer datasheet GS 01C31F01-01EN for this model family is attached to the product page as a PDF. When you request a quotation, send the full part number EJA510E-JCS7N-012DN, the quantity, the tag or loop number, the process fluid and any approval code you need such as ATEX, IECEx, FM or CSA. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Lead times and availability are confirmed per request.
Other Models in the EJA510E Range
Seven Star LLC supplies models from the EJA510E range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Yokogawa EJA510E-JBS4N-012NN Absolute Pressure Transmitter | Pressure Transmitters | View details |
| Yokogawa EJA510E-JCS7N-012DN Absolute Pressure with LCD | Pressure Transmitters | You are viewing this model |
Datasheets & Documents
- Datasheet Yokogawa EJA510E-JCS7N-012DN Absolute Pressure with LCD Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa EJA510E-JCS7N-012DN Absolute Pressure with
Answers from our engineering team on installation, compatibility and integration.
01What is different between this and EJA510E-JBS4N-012NN?
This one uses the C capsule, a 1/2 NPT male connection and an integral digital indicator; the other uses the B capsule, a female connection and no indicator.
02Can the LCD of EJA510E-JCS7N-012DN be used to re-range?
The D indicator only displays. Local re-ranging by push button needs indicator code E, which includes the range-setting switch.
03What pressure can the C capsule survive?
Over-pressure is 20 MPa abs and burst pressure is 30 MPa according to the datasheet. Continuous working pressure is limited to 10 MPa abs.
04How is the 1/2 NPT male thread sealed?
Use a thread sealant suitable for the process fluid and tighten on the connector flats. The datasheet only specifies the thread type.
05Does this model hold SIL 2?
The EJA-E series in standard HART configuration is certified SIL 2 capable for single use and SIL 3 for dual transmitters, per the datasheet.


















Reviews