Yokogawa EJA510E-JCS7N-012DN Absolute Pressure with LCD

Description

Why EJA510E-JCS7N-012DN suits a male-threaded tapping

Not every process tapping is a female thread. Yokogawa EJA510E-JCS7N-012DN carries a 1/2 NPT male connection, so it screws straight into a female coupling or a threaded boss on a vessel, a manifold block or a compressor discharge fitting without a nipple. The transmitter measures absolute pressure with the C capsule across a span of 0.1 to 10 MPa abs, and an integral digital indicator is already fitted, so an operator can read pressure at the field location without a handheld.

The output is 4 to 20 mA with HART. Everything else in the suffix is the common stainless and aluminum build, so replacement stock is straightforward.

Breaking down the JCS7N-012DN code

Code position Meaning
-J 4 to 20 mA DC with HART 5 or HART 7 digital communication (selected at ordering)
C Capsule: span 0.1 to 10 MPa
S 316L SST process connector, Hastelloy C-276 diaphragm, 316L SST or F316L SST other wetted parts
7 Process connection: 1/2 NPT male
1 Amplifier housing: cast aluminum alloy
2 Electrical: 1/2 NPT female, two electrical connections, no blind plugs
D Integral indicator: digital indicator
N Mounting bracket: none

What the C capsule gives you

Where the B capsule stops at 2 MPa abs, the C capsule covers 0.1 to 10 MPa abs. Maximum working pressure is 10 MPa abs and over-pressure is 20 MPa abs; burst pressure is quoted as 30 MPa. Accuracy is plus or minus 0.055 percent of span at spans of 1 MPa or larger. Ten-year stability for the EJA510E is plus or minus 0.2 percent of URL. The ambient temperature effect is the same plus or minus (0.15 percent span plus 0.15 percent URL) per 28 degrees C seen in the A and B capsules, so large spans are the better use of the C capsule.

Process fluids and materials for EJA510E-JCS7N-012DN

The S wetted-parts code means a 316L stainless process connector and a Hastelloy C-276 diaphragm, with 316L or F316L stainless elsewhere. The datasheet marks these materials as conforming to NACE MR0175 and ISO 15156 recommendations, and states that they also conform to MR0103. Silicone oil is the standard fill fluid, and a fluorinated oil capsule is an optional code. The datasheet cautions that wetted-material selection is the buyer responsibility, particularly for hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite and steam at 150 degrees C or more. For EJA510E-JCS7N-012DN, the process temperature limit is minus 40 to 120 degrees C.

Key facts about EJA510E-JCS7N-012DN at a glance

Parameter Data
Capsule C span 0.1 to 10 MPa abs
URL / MWP 10 MPa abs
Over-pressure 20 MPa abs
Output 4 to 20 mA, HART 5 or 7
Process connection 1/2 NPT male
Wetted material 316L SST with Hastelloy C-276 diaphragm
Integral indicator Digital LCD, up to three variables shown periodically
Ambient limit Minus 30 to 80 degrees C with LCD
Housing code 1, cast aluminum, IP66/IP67
Electrical 1/2 NPT female x2
Response 90 ms
Weight About 1.2 kg before options

Applications for a C capsule absolute transmitter

The C capsule matches the pressure level of compressed-air headers, high-pressure steam let-down, hydraulic power units and gas gathering lines. In Gulf plants it often shows up on reciprocating-compressor stages, fuel gas conditioning skids, and pump discharge on water injection, wherever site ambient pressure variation would be unwelcome in the measurement. The integral display saves a technician a trip to the control room when verifying a pressure switch setpoint.

EJA510E-JCS7N-012DN compared with sibling codes

Compared with the 1/2 NPT female option, the male thread removes one adapter and one leak path but demands a female counterpart on the tapping. Compared with the plain NN version, adding the D indicator costs nothing in wetted construction and the LCD lowers the allowed ambient range to minus 30 degrees C at the cold end. If you need push-button re-ranging at the device, the indicator code E, not D, is the one that includes the range-setting switch.

Fitting and wiring EJA510E-JCS7N-012DN

Tighten the male thread into the coupling by wrench on the process connector flats only, never by twisting the housing. Rotate the housing and the indicator to a readable angle before commissioning. Use the two 1/2 NPT conduit entries for power and, if required, a loop-powered relay; plug the unused entry. HART communication needs at least 250 ohm of load and minimum 16.6 V at the terminals, so check the supply and barrier voltage drop before final wiring.

Look for moisture inside the terminal compartment at each inspection, confirm that the display units match the loop sheet and review the self-diagnostic alarms stored in the device. Because the transmitter is vacuum-referenced, a zero check should be done with the connection vented to vacuum, not simply open to atmosphere.

The same transmitter family offers more than EJA510E-JCS7N-012DN. If you are replacing a damaged unit and the nameplate reads differently, say so in the inquiry: an A or B capsule needs the lower pressure window, a gauge-pressure EJA530E replaces an absolute unit only when vacuum reference is not needed, and the HART option is not interchangeable with BRAIN without checking the host. Optional codes after the slash, for instance degreasing for oxygen service, fluorinated oil fill or gold-plated diaphragm for hydrogen service, change the product and must be quoted explicitly. The datasheet lists these options in detail, and EJA510E-JCS7N-012DN is quoted without them unless you request otherwise.

Many maintenance teams also keep a 2-inch pipe bracket in stock, since this specific code was ordered with the bracket field set to N.

Quick answers about EJA510E-JCS7N-012DN

  • What is different between this and EJA510E-JBS4N-012NN? This one uses the C capsule, a 1/2 NPT male connection and an integral digital indicator; the other uses the B capsule, a female connection and no indicator.
  • Can the LCD of EJA510E-JCS7N-012DN be used to re-range? The D indicator only displays. Local re-ranging by push button needs indicator code E, which includes the range-setting switch.
  • What pressure can the C capsule survive? Over-pressure is 20 MPa abs and burst pressure is 30 MPa according to the datasheet. Continuous working pressure is limited to 10 MPa abs.
  • How is the 1/2 NPT male thread sealed? Use a thread sealant suitable for the process fluid and tighten on the connector flats. The datasheet only specifies the thread type.
  • Does this model hold SIL 2? The EJA-E series in standard HART configuration is certified SIL 2 capable for single use and SIL 3 for dual transmitters, per the datasheet.

Documents and quotation

If you hold a data sheet from the plant, send us the tag number as well so we can match the suffix exactly.

The manufacturer datasheet GS 01C31F01-01EN for this model family is attached to the product page as a PDF. When you request a quotation, send the full part number EJA510E-JCS7N-012DN, the quantity, the tag or loop number, the process fluid and any approval code you need such as ATEX, IECEx, FM or CSA. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Lead times and availability are confirmed per request.

Other Models in the EJA510E Range

Seven Star LLC supplies models from the EJA510E range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa EJA510E-JBS4N-012NN Absolute Pressure TransmitterPressure TransmittersView details
Yokogawa EJA510E-JCS7N-012DN Absolute Pressure with LCDPressure TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Yokogawa EJA510E-JCS7N-012DN Absolute Pressure with LCD Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa EJA510E-JCS7N-012DN Absolute Pressure with

Answers from our engineering team on installation, compatibility and integration.

01What is different between this and EJA510E-JBS4N-012NN?
This one uses the C capsule, a 1/2 NPT male connection and an integral digital indicator; the other uses the B capsule, a female connection and no indicator.
02Can the LCD of EJA510E-JCS7N-012DN be used to re-range?
The D indicator only displays. Local re-ranging by push button needs indicator code E, which includes the range-setting switch.
03What pressure can the C capsule survive?
Over-pressure is 20 MPa abs and burst pressure is 30 MPa according to the datasheet. Continuous working pressure is limited to 10 MPa abs.
04How is the 1/2 NPT male thread sealed?
Use a thread sealant suitable for the process fluid and tighten on the connector flats. The datasheet only specifies the thread type.
05Does this model hold SIL 2?
The EJA-E series in standard HART configuration is certified SIL 2 capable for single use and SIL 3 for dual transmitters, per the datasheet.