Endress+Hauser 8E1B Promass E 100 Coriolis Flowmeter

Description

Endress+Hauser 8E1B Promass E 100: the economical dual-tube Coriolis meter

Anyone who has priced a Coriolis flowmeter knows the cost gap to a magnetic or vortex meter. The Endress+Hauser 8E1B closes much of that gap. It is the Proline Promass E 100, described in its technical information TI01021D as the flowmeter with minimum total cost of ownership, a compact dual-tube sensor paired with an ultra-compact transmitter. The nominal sizes run from DN 8 to DN 80 (3/8 to 3 inch), so it covers the pipework where most plant operators actually need mass measurement.

The 8E1B measures mass flow, density and temperature in one device. Full scale values for liquids start at 2,000 kg/h on DN 8 and climb to 180,000 kg/h on DN 80. The datasheet positions it as an alternative to conventional volumetric meters for standard liquids and gases, with no moving parts and no dependency on viscosity or conductivity.

What the 8E1B brings to a standard measuring point

  • Two parallel stainless measuring tubes, tube material 904L (1.4539) according to the datasheet
  • Medium temperature from minus 40 to plus 140 °C, process pressure up to 100 bar (1,450 psi)
  • Mass flow accuracy of 0.15 percent of reading for liquids, 0.75 percent for gases
  • Density range 0 to 5,000 kg/m3, no internal seals in the sensor
  • IP66/67 enclosure, IP69K available with sensor option CM
  • Flange choices cover EN 1092-1, NAMUR lengths per NE 132, ASME B16.5 and JIS B2220, plus clamp and DIN 11864-2 flange
  • Heartbeat Technology and an integrated web server for local operation

8E1B datasheet values at a glance

Figures in the following table are taken from TI01021D. They describe the standard product root; selected options in the order code may narrow or widen individual entries.

Parameter Value for 8E1B
Product root 8E1B, Proline Promass E 100
Sensor Compact dual-tube Coriolis
Nominal diameter range DN 8 to 80 (3/8 to 3 inch)
Full scale, DN 8 / DN 15 2,000 / 6,500 kg/h
Full scale, DN 25 / DN 40 18,000 / 45,000 kg/h
Full scale, DN 50 / DN 80 70,000 / 180,000 kg/h
Mass flow accuracy, liquids 0.15 percent of reading
Mass flow accuracy, gases 0.75 percent of reading
Medium temperature Minus 40 to plus 140 °C (minus 40 to plus 284 °F)
Process pressure Up to 100 bar (1,450 psi)
Density range 0 to 5,000 kg/m3
Tube material Stainless steel 1.4539 (904L)
Weight, PN 40 flanges 6 kg at DN 8 and DN 15, 8 kg DN 25, 13 kg DN 40, 20 kg DN 50, 29 kg DN 80
Supply voltage DC 20 to 30 V
Ambient temperature Minus 40 to plus 60 °C
Protection IP66/67; IP69K with sensor option CM

Typical duties for the 8E1B in Omani and GCC industry

The cost position makes the 8E1B a workhorse for custody-adjacent but not fiscal duty: lube oil and fuel bunkering skids, chemical batching in detergent and paint plants, glycol circuits in district cooling, and boiler fuel measurement at power and water stations. Where a plant has dozens of similar measuring points, the 8E1B lets engineers standardise on one Coriolis platform instead of mixing meter types.

Gas measurement is possible within the stated 0.75 percent of reading accuracy, which suits utility gas, air and nitrogen where mass balance matters more than ultimate precision. For hot services above 140 °C or for high-pressure oil and gas duty, look to sibling lines instead.

How 8E1B differs from other Promass E variants

Inside the Promass E family the 100 generation uses an ultra-compact housing and DC 20 to 30 V supply. The E 200 is a loop-powered two-wire device with a separate connection compartment and supports HART, PROFIBUS PA and FOUNDATION Fieldbus. The E 300 raises temperature to 150 °C and improves liquid accuracy to 0.15 percent, with 0.10 percent for selected calibration options, while adding WLAN and up to three I/Os.

Numerically, the 8E1B sits at 0.15 percent liquid accuracy and 140 °C maximum; the E 200 quotes 0.25 percent; the E 300 and E 500 reach 150 °C. All share the DN 8 to 80 span. Choose the 8E1B when a simple, compact transmitter and an IP69K option matter more than extra I/O.

Selecting an 8E1B configuration

Check three items first: the nominal diameter implied by your normal and maximum flow, the connection standard of the existing pipeline, and the communication type. The datasheet lists HART, PROFIBUS DP, Modbus RS485 and EtherNet/IP behaviour for the 100 platform, and Modbus RS485 can be ordered for intrinsically safe areas where power comes via the Safety Barrier Promass 100.

If the medium is hygienic, the clamp and DIN 11864-2 connections are on the list, but pharmaceutical users should compare with the Promass S or H lines. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Our quotation will repeat the configuration you give us so that nothing is lost between the order and the shipment.

Installation and maintenance of 8E1B

The dual-tube sensor tolerates normal pipe stress, yet it should be installed without strong vibration sources nearby and, for liquids, with the tubes fully filled. No inlet or outlet run is needed. When the medium is hot, observe the dependency of ambient temperature on medium temperature given in the document and insulate with care.

Because the sensor contains no internal seals, routine maintenance is mostly electrical: check cable glands, keep the cover closed to preserve IP66/67, and use Heartbeat Technology for in-situ verification. The web server makes parameter backup and diagnostics possible from a laptop without opening the housing.

Frequently asked questions about 8E1B

What sizes does the 8E1B cover? The datasheet gives a nominal diameter range of DN 8 to 80, which is 3/8 to 3 inch.

What is the liquid mass flow accuracy of the 8E1B? The datasheet quotes 0.15 percent of reading for liquid mass flow and 0.75 percent of reading for gases.

Can the 8E1B be washed down? IP66/67 is standard and IP69K can be selected with sensor option CM according to the datasheet.

How hot and how pressurised can the medium be? Medium temperature is minus 40 to plus 140 °C and process pressure is up to 100 bar (1,450 psi).

How do I request an 8E1B quotation? Send an RFQ to Seven Star LLC with 8E1B, nominal diameter, connection standard, output type and quantity.

Documents and quotation

The technical information TI01021D is supplied as the datasheet for the 8E1B and holds dimensions, pressure ratings and ordering structure.

Please include part number 8E1B, quantity, nominal size and delivery destination when you send the RFQ so our reply is complete.

Datasheets & Documents
  • PDF Datasheet Endress+Hauser 8E1B Promass E 100 Coriolis Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser 8E1B Promass E 100 Coriolis Flowmeter

Answers from our engineering team on installation, compatibility and integration.

01What sizes does the 8E1B cover?
The datasheet gives a nominal diameter range of DN 8 to 80, which is 3/8 to 3 inch.
02What is the liquid mass flow accuracy of the 8E1B?
The datasheet quotes 0.15 percent of reading for liquid mass flow and 0.75 percent of reading for gases.
03Can the 8E1B be washed down?
IP66/67 is standard and IP69K can be selected with sensor option CM according to the datasheet.
04How hot and how pressurised can the medium be?
Medium temperature is minus 40 to plus 140 °C and process pressure is up to 100 bar (1,450 psi).
05How do I request an 8E1B quotation?
Send an RFQ to Seven Star LLC with 8E1B, nominal diameter, connection standard, output type and quantity.