Moore Industries SSX/4-20MA/4-20MA/12-42DC/-IZ250 [DIN] Isolator

Description

Moore Industries SSX/4-20MA/4-20MA/12-42DC/-IZ250 [DIN]: SSX with a 250 ohm input for safety loops

Moore Industries SSX/4-20MA/4-20MA/12-42DC/-IZ250 [DIN] is the two-wire, loop-powered SSX safety isolator with the -IZ250 option. The option raises the input resistance from the standard 100 ohms to 250 ohms, which suits loops where the transmitter or the safety system expects a 250 ohm sense resistor in the path. The SSX draws its power from the output side, typically from a DCS or PLC.

It belongs to the FS Functional Safety Series, certified by exida to IEC 61508:2010. It is SIL 3 capable in monitor mode, where only the input circuit is part of the safety function, and SIL 2 in single use.

In a typical SIS design the field transmitter feeds the safety logic solver directly and the isolator feeds a secondary system. The SSX with 250 ohms at the input is sometimes picked when the monitoring system lacks its own sense resistor, so the isolator provides it. The loop designer must then include the 250 ohms in the loop voltage budget along with the cable and any barrier.

Why choose SSX/4-20MA/4-20MA/12-42DC/-IZ250 [DIN]

  • Isolates the safety system from the basic process control system so a failure in the monitoring system does not disturb the safety signal.
  • Passes HART data between the field transmitter and the host system in both directions, so asset management tools remain functional.
  • Provides 1500 Vrms surge isolation testing for protection of safety I/O cards.
  • Needs no separate supply: the loop provides the power on the output side.
  • FMEDA data from exida is available on request.

The -IZ250 option is only possible on 4-20 mA input models and cannot be combined with -0HART.

SSX/4-20MA/4-20MA/12-42DC/-IZ250 [DIN] specification data

Values come from the SSX/SST datasheet.

Parameter Value for SSX/4-20MA/4-20MA/12-42DC/-IZ250 [DIN]
Model code SSX/4-20MA/4-20MA/12-42DC/-IZ250 [DIN]
Unit SSX 2-wire loop-powered safety isolator
Safety exida certified IEC 61508:2010: SIL 3 capable in monitor mode; SIL 2 in single use
Input 4-20 mA, 250 ohms with the -IZ250 option (100 ohms standard)
Output 4-20 mA isolated, into 600 ohms with 24 V DC power
Supply 12-42 V DC, drawn from the output side of the loop
Option -IZ250 Increases input resistance to 250 ohms; not available with -0HART; 4-20 mA input models only
Accuracy Plus or minus 0.1% of span
Isolation 500 Vrms between input, output and case; tested at 1500 Vrms for 1 minute
Response 100 ms maximum to 99% of output
Load capability Supply voltage minus 12 V DC at 20 mA
Output limiting 25 mA typical, 30 mA maximum
Output tracking Follows the input below 3 mA when the input fails
Weight 8 oz (227 g)
HART Pass-through of HART data in both directions
Ambient -40 to +85 C; 5-95% RH non-condensing

Compare the load line carefully: the SSX output side offers supply minus 12 V at 20 mA, so a 24 V supply leaves 12 V, or about 600 ohms, for the receiving device and cable. The output current is limited to 25 mA typical and 30 mA maximum, which protects the receiving card during a fault.

How SSX/4-20MA/4-20MA/12-42DC/-IZ250 [DIN] differs from the plain SSX and from the SST

The standard SSX input resistance is 100 ohms; this code has 250 ohms. If you are replacing an SSX with 100 ohms in a loop, the extra 150 ohms adds about 3 V of drop at 20 mA, so you must verify the loop compliance voltage. The SST is a four-wire mains or 24 V powered unit with a dual-output splitter; this SSX is a single-channel, two-wire loop device that weighs 8 oz against 12 oz for the single-channel SST.

Both families share the 0.1% accuracy and the 1500 Vrms test isolation.

Applications

Typical uses are isolating a safety transmitter from a monitoring DCS, protecting a safety PLC input card from a plant loop, or supplying a 250 ohm sense element for a card that does not have one. It is frequent in emergency shutdown loops of pressure, flow and level transmitters.

Because the isolator passes HART, a handheld can be connected on either side of it for diagnostics.

Selection notes

Make sure the loop supply on the output side delivers enough voltage for the extra input resistance, remembering the load limit of the supply minus 12 V DC at 20 mA. Check that the receiving device accepts the output range with the 250 ohm added.

If HART data are not needed, other option sets may be more suitable; ask us to confirm the combination you require.

Installation

Mount the DIN housing on a 35 mm Top Hat rail, wire the input and the output, and trim zero and span (plus or minus 2%) with the front pots if required. An optional flange bracket helps in high-vibration locations.

Check the loop current with a calibrator and compare with the field transmitter reading.

When the isolator is first powered, check that the output follows the input smoothly, then simulate input loss with a calibrator to see the tracking below 3 mA. Record the results in the commissioning report next to the code SSX/4-20MA/4-20MA/12-42DC/-IZ250 [DIN] so the safety file shows evidence that the isolator behaves as documented.

Proof test and maintenance

Use the FMEDA information to set the proof-test interval. At test time, verify accuracy at several points, confirm the output tracking behaviour when the input is lost, and inspect terminals.

Stability is quoted as plus or minus 0.2% of reading per year.

Supply of SSX/4-20MA/4-20MA/12-42DC/-IZ250 [DIN]

Quote SSX/4-20MA/4-20MA/12-42DC/-IZ250 [DIN] in full when requesting stock and state if FMEDA documents are needed.

Seven Star LLC is an independent supplier serving Oman and the wider GCC and is not affiliated with the manufacturer; all names and part numbers are used only to identify the product being requested.

Documents and quotation

The datasheet for Moore Industries SSX/4-20MA/4-20MA/12-42DC/-IZ250 [DIN] can be attached to our quotation. Please send an RFQ with part number, quantity and delivery location.

Datasheets & Documents
  • PDF Datasheet Moore Industries SSX/4-20MA/4-20MA/12-42DC/-IZ250 [DIN] Isolator Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.

Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.

Moore Industries company profile

Founded 1968, North Hills, California, USA, by Leonard W. Moore
Headquarters North Hills, California, since 1974
Ownership Privately owned (Moore Industries-International, Inc.)
First product SCT signal converter
Product families Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA)

Milestones

  • 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
  • 1974: The company moves into its North Hills headquarters.
  • 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.

Moore Industries product families on this page

The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:

  • Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
  • Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
  • Signal isolators, repeaters and converters: the SIX
  • PID controllers and backup stations: the 535 in 1/4 DIN format

Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.

Where Moore Industries instruments are used

These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.

Moore Industries products we list

Family Examples
Controllers & Data Acquisition Moore 535-21120BD000 | Industrial PID Ba…, SPA2 Programmable Limit Alarm Trip, Moore-SPA2HL Associated IS Programmable…
Isolator & Barrier HIM Smart HART Loop Interface and Monitor, SIX Signal Isolator, SLA SIL 2/3 Safety Logic Solver and Alarm
Temperature Instrumentation STZ Functional Safety Dual Input Smart H…, TRX Temperature Transmitter
Industrial Communications HES HART to Ethernet Gateway
Valve Positioners IPT2 Current-to-Pressure I/P Transmitter

Ordering Moore Industries instruments: what we need

Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.

Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.

FAQ

Questions about the Moore Industries SSX/4-20MA/4-20MA/12-42DC/-IZ250

Answers from our engineering team on installation, compatibility and integration.

01What does -IZ250 do?
It increases the input resistance to 250 ohms; it is available only on 4-20 mA input models and cannot be used with -0HART.
02Is the SSX loop powered?
Yes. It is a 2-wire device powered from the output side of the loop with 12-42 V DC.
03What SIL level does it support?
SIL 3 capable in monitor mode and SIL 2 in single use, certified by exida to IEC 61508:2010.
04How much does it weigh?
The datasheet lists 8 oz (227 g) for the SSX isolator in its DIN housing.
05Does it pass HART data?
Yes, the SSX passes HART data between the field transmitter and the host system.