Moore HIM/HART/3AO/24DC/-2PRG [DIN] overview

The Moore HIM/HART/3AO/24DC/-2PRG [DIN] is a HART Loop Interface and Monitor from Moore Industries. It reads the digital HART data of a smart multivariable transmitter or valve positioner and converts selected variables to up to three additional 4-20 mA analog signals, with no extra process penetration or wiring.

The -2PRG option adds two programmable relay outputs, which can be set from HART variables or from the HART instrument diagnostic and fault alarm. The manufacturer says it works with every HART-compatible device and is set up with a simple PC program.

The part number HIM/HART/3AO/24DC/-2PRG [DIN] follows the ordering pattern of the manufacturer datasheet, which lists the fields in this order: unit, input, output, power, options and housing (Unit / Input / Output / Power / Options [Housing]). The string written as HIM/HART/3AO/24DC/-2PRG [DIN] is the model example printed in that datasheet, so it describes one complete configuration. If your plant needs a different input, output, supply, option or housing, send the configuration with your RFQ and it will be checked against the ordering table.

  • HIM: HART loop interface and monitor
  • HART: accepts HART digital data from a smart field device
  • 3AO: three programmable analog output channels
  • 24DC: 24 Vdc, plus or minus 10%
  • -2PRG: two programmable SPDT alarm relays
  • [DIN]: DIN-style housing for 35 mm Top Hat rail

Key features of the Moore Industries HIM/HART/3AO/24DC/-2PRG [DIN]

  • Converts HART digital variables into three analog outputs.
  • Two user-programmable alarm outputs through SPDT relays (-2PRG).
  • Instrument diagnostic alarm based on selectable HART status bits.
  • Lets legacy smart transmitters and valves stay in place.
  • Response time defined by HART as 500 ms maximum in normal mode and 333 ms in burst mode.
  • CSA approval for general and Class I Division 2 Groups A-D locations on the -2PRG option, per the datasheet.

Technical specifications for HIM/HART/3AO/24DC/-2PRG [DIN]

Parameter Value
Model string Moore HIM/HART/3AO/24DC/-2PRG [DIN]
Input HART digital protocol from smart field device; input impedance 150 ohms transmit, less than 5 kohms receive
Analog outputs Three programmable channels; accuracy plus or minus 0.015% of maximum output span (20 mA)
Output response time Less than 120 ms, 10-90%
Alarm relays (-2PRG) SPDT, 1 form C, 5 A at 250 Vac 50/60 Hz, non-inductive
Alarm trip delay 0 to 120 seconds programmable
Isolation 500 Vrms channel to channel; 1000 Vrms between case, input, outputs and power; 1500 Vac dielectric test for one minute
Ripple Less than 10 mV peak-to-peak across 250 ohms
Output limiting 130% of span maximum; 125% typical
Modbus (on MB models) RTU over RS-485, address 1-247

The values above come from the manufacturer datasheet for the HIM family. Specifications can differ by input type and option, so read the matching page of the datasheet before finalising a purchase specification and keep the complete model string on your purchase documents. Where a value is not listed here it was not stated clearly enough in the datasheet to repeat.

Typical applications of the HIM/HART/3AO/24DC/-2PRG [DIN] in Oman and the GCC

Typical uses include reading flow, temperature and pressure variables from one multivariable transmitter on three analog inputs of the DCS.

In oil and gas, petrochemical and power plants, many smart HART transmitters and valve positioners are installed with only one analog signal wired back to the control system. A HART interface and monitor like the HIM/HART/3AO/24DC/-2PRG [DIN] lets the plant read additional dynamic variables or diagnostics without opening the process.

It is useful on multivariable flow and temperature-pressure transmitters, on valve positioners with position or air pressure information, and on legacy smart instruments that must stay in place.

Used in the Gulf region, the DIN-rail housing fits standard marshalling cabinets and the Modbus option can pass the data to PLC or SCADA networks.

Selection and compatibility notes for HIM/HART/3AO/24DC/-2PRG [DIN]

Check that the field device supports HART and which dynamic variables it can burst or report. The Modbus model is a different configuration string.

Confirm that the field device supports the HART variables you want to read and decide how many analog outputs, relays and communications channels the application needs.

Check the supply voltage field of the part number and the cabinet power available, and check the relay option against the area classification stated in the datasheet.

Send the make and model of the HART device with the RFQ so that compatibility can be checked.

Installation and commissioning

Mount the HIM/HART/3AO/24DC/-2PRG [DIN] on its rail in a clean cabinet and connect the HART loop, supply, analog outputs and any relay or Modbus wiring according to the manufacturer terminal drawing.

Connect to a PC with the configuration software, scan for the HART device, and select the dynamic variables, scaling and alarm conditions. Verify every output against a known HART source.

Record the settings and keep the configuration file with the loop documentation.

Maintenance and spares

Check outputs against the field device at the interval of your calibration plan, review the HART status bits assigned to the alarm, and keep the configuration file safely stored so a replacement unit can be set up quickly.

Check terminals and cabinet conditions at each outage.

Related products and ordering notes

The HIM is related to the HIT and HIX HART isolators on the site. The datasheet and configuration software are available from the manufacturer.

Unit and accessory part numbers such as those named above are separate line items. Please list each one with its quantity so that the quotation covers the complete package. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Frequently asked questions about HIM/HART/3AO/24DC/-2PRG [DIN]

  • What does the HIM/HART/3AO/24DC/-2PRG [DIN] do? It reads HART digital data from a smart device and converts selected variables to analog outputs and relay alarms.
  • How many analog outputs does the HIM/HART/3AO/24DC/-2PRG [DIN] provide? The 3AO output option provides three programmable analog output channels.
  • What power does the HIM/HART/3AO/24DC/-2PRG [DIN] need? The 24DC option is a 24 Vdc supply with plus or minus 10% tolerance.
  • What does -2PRG mean on the HIM/HART/3AO/24DC/-2PRG [DIN]? It adds two user-programmable SPDT alarm relays rated 5 A at 250 Vac.
  • How do I request the HIM/HART/3AO/24DC/-2PRG [DIN]? Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.

Documents and quotation

The manufacturer datasheet for the HIM family is available from us on request and a copy is attached to this page. It contains the full ordering table, specifications and dimension drawings, and we suggest reading it before you decide on the final configuration.

To request a quotation, send an RFQ that includes the part number HIM/HART/3AO/24DC/-2PRG [DIN], the quantity, the delivery location in Oman or the GCC and any special requirement such as certification documents or a required delivery date. Our team will confirm availability and lead time and reply with a written offer.

Datasheets & Documents
  • PDF Datasheet HIM HART Interface Module with Three Analog Outputs Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.

Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.

Moore Industries company profile

Founded 1968, North Hills, California, USA, by Leonard W. Moore
Headquarters North Hills, California, since 1974
Ownership Privately owned (Moore Industries-International, Inc.)
First product SCT signal converter
Product families Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA)

Milestones

  • 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
  • 1974: The company moves into its North Hills headquarters.
  • 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.

Moore Industries product families on this page

The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:

  • Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
  • Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
  • Signal isolators, repeaters and converters: the SIX
  • PID controllers and backup stations: the 535 in 1/4 DIN format

Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.

Where Moore Industries instruments are used

These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.

Moore Industries products we list

Family Examples
Controllers & Data Acquisition Moore 535-21120BD000 | Industrial PID Ba…, SPA2 Programmable Limit Alarm Trip, Moore-SPA2HL Associated IS Programmable…
Isolator & Barrier HIM Smart HART Loop Interface and Monitor, SIX Signal Isolator, SLA SIL 2/3 Safety Logic Solver and Alarm
Temperature Instrumentation STZ Functional Safety Dual Input Smart H…, TRX Temperature Transmitter
Industrial Communications HES HART to Ethernet Gateway
Valve Positioners IPT2 Current-to-Pressure I/P Transmitter

Ordering Moore Industries instruments: what we need

Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.

Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.

FAQ

Questions about the HIM/HART/3AO/24DC/-2PRG [DIN] HART Interface Module

Answers from our engineering team on installation, compatibility and integration.

01What does the HIM/HART/3AO/24DC/-2PRG [DIN] do?
It reads HART digital data from a smart device and converts selected variables to analog outputs and relay alarms.
02How many analog outputs does the HIM/HART/3AO/24DC/-2PRG [DIN] provide?
The 3AO output option provides three programmable analog output channels.
03What power does the HIM/HART/3AO/24DC/-2PRG [DIN] need?
The 24DC option is a 24 Vdc supply with plus or minus 10% tolerance.
04What does -2PRG mean on the HIM/HART/3AO/24DC/-2PRG [DIN]?
It adds two user-programmable SPDT alarm relays rated 5 A at 250 Vac.