Brand:

Pepperl+Fuchs KFD2-STC4-Ex2 2-Channel Transmitter Supply

Description

KFD2-STC4-Ex2: two SMART transmitters in one 20 mm module

The Pepperl+Fuchs KFD2-STC4-Ex2 is the two-channel member of the STC4 generation. Each channel supplies a 2-wire SMART transmitter in a hazardous area, isolates the 0/4 to 20 mA signal and passes it to the safe area as a current that the control system can read into up to 550 ohm. Two channels sharing a 20 mm housing halve the footprint per loop, which is useful on skids with long strings of pressure and temperature transmitters.

The datasheet revision of this model dates to the K-System family that is still widely installed in Gulf refineries and gas plants, so the part is a frequent spare for plants that have not migrated to the newer STC5 range.

Capabilities

  • Two independent channels: input terminals 1+, 3- and 4+, 6-; output terminals 7-, 8+ and 10-, 11+
  • 250 ohm internal resistor between terminals 8 and 9, and between 11 and 12, available as HART communication resistance
  • Test sockets for HART communicators built into the terminals
  • Supports HART, BRAIN and Foxboro protocols
  • SIL 2 capable (IEC/EN 61508)

KFD2-STC4-Ex2 data

Parameter Value
Supply 20 to 35 V DC, terminals 14+ and 15-
Power dissipation / consumption 1.8 W / up to 2.7 W
Input 0/4 to 20 mA, at least 16 V available at 20 mA
Output 0/4 to 20 mA, load 0 to 550 ohm at 20 mA, overload above 25 mA
Output ripple up to 50 microamps rms
Deviation at 20 degrees C up to 10 microamps incl. calibration, linearity and hysteresis
Temperature influence 0.25 microamps per K
Bandwidth 0 to 7.5 kHz field to control; 0.3 to 7.5 kHz control to field (3 dB)
Settling time / rise and fall 200 microseconds / 20 microseconds
Isolation functional, 50 V AC between outputs and supply and between outputs
ATEX certificate BAS 99 ATEX 7025 X, [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Dimensions, mass 20 x 124 x 115 mm, housing B2, about 150 g
Ambient -20 to 60 degrees C

Where two channels pay off

Redundant transmitters, such as two pressure transmitters on one vessel, are well served by a two-channel barrier because the pair can be verified side by side. A distillation column with temperature profile transmitters can place eight channels in four modules, giving a tidy row on the rail. The design also reduces Power Rail connections, since one supply pair feeds both channels.

How KFD2-STC4-Ex2 differs from other STC4 types

  • KFD2-STC4-Ex1.H has a single channel with 17.6 V field voltage, whereas this model supplies at least 16 V per channel at 20 mA on two channels.
  • Unlike the single-channel H type, this two-channel module is intended for 2-wire SMART transmitters only.
  • Supply range is 20 to 35 V DC, broader at the top than the 18 to 30 V of the STC5 family.

Wiring

Connect field wiring to terminals 1+, 3- and 4+, 6-, observing polarity. Power connects to 14+ and 15- or the Power Rail. On the control side, use 7-, 8+ for channel I and 10-, 11+ for channel II. If the receiver impedance is under the 250 ohm needed for HART, link the receiver to the internal resistor at terminals 8 and 9 or 11 and 12.

Maintenance

Test both channels with a calibrator annually. When a channel fails, the module should be exchanged, as the two channels share the housing and supply circuitry.

Using it as a spare

Because installed STC4 stock is large, many Oman operators carry spare modules; verify the number of channels and supply range of the installed unit before selecting.

Reading the safe-area values

The entity parameters begin with Uo 25.2 V on the field side; the complete set on the datasheet should be compared with transmitter and cable parameters in the loop calculation. The certificate BAS 99 ATEX 7025 X contains special conditions marked by the suffix X, which must be observed during installation.

Loop-check routine for a two-channel module

During commissioning, number the channels on the cabinet drawing as I and II to match the terminal groups, then inject 4, 12 and 20 mA with a simulator at the field side of each channel in turn while reading the control-side value. The measured values should agree within the 10 microamp deviation given in the datasheet, plus the tolerance of the meter. Disconnect channel II while testing channel I to prove that the channels do not influence each other, and note the supply current before and after to confirm the 1.8 W dissipation is not exceeded. Operators in hot climates should log module temperature, because two channels in one housing generate more heat than a single-channel module of the same size.

Questions buyers ask about KFD2-STC4-Ex2

How many channels does KFD2-STC4-Ex2 provide? It provides two isolated channels for 2-wire SMART transmitters in a 20 mm housing.

What supply voltage does KFD2-STC4-Ex2 need? The rated supply voltage is 20 to 35 V DC on terminals 14+ and 15-, with a consumption of up to 2.7 W.

What load can each output of KFD2-STC4-Ex2 drive? Each output drives 0 to 550 ohm at 20 mA, with overload detection above 25 mA.

Is HART communication possible with KFD2-STC4-Ex2? Yes. Digital signals are transferred bi-directionally, and an internal 250 ohm resistor is available between terminals 8 and 9 and between 11 and 12.

Which ATEX certificate covers KFD2-STC4-Ex2? The datasheet lists EU-type examination certificate BAS 99 ATEX 7025 X.

Documents and quotation

The manufacturer datasheet for KFD2-STC4-Ex2 accompanies this listing as a PDF so your engineers can verify terminals, ratings and approvals before purchase. Tell us how many loops you plan to cover. To request a quotation, send the RFQ with the exact part number KFD2-STC4-Ex2, the quantity, the delivery location in Oman or the GCC and any project reference. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Other Models in the Stc4 Transmitter Range

Seven Star LLC supplies models from the Stc4 Transmitter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Pepperl+Fuchs KFD2-STC4-Ex1.H Transmitter SupplyIsolator & BarrierView details
Pepperl+Fuchs KFD2-STC4-Ex2 2-Channel Transmitter SupplyIsolator & BarrierYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Pepperl+Fuchs KFD2-STC4-Ex2 2-Channel Transmitter Supply Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.

Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.

Pepperl+Fuchs company profile

Founded 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs
Headquarters Mannheim, Germany
Ownership Privately owned (Pepperl+Fuchs SE)
Origins Radio repair workshop that began making replacement transformers
Product families Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures

Milestones

  • 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
  • 1958: The first proximity switch is developed (some company sources say 1959).

Pepperl+Fuchs product families on this page

On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.

Where Pepperl+Fuchs equipment is used

Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.

Pepperl+Fuchs products we list

Family Examples
Isolator & Barrier HiD2030 SMART Transmitter Power Supply w…, KFD2-SR2-Ex2.W K-System Isolated Switch…, KFD2-UT2-Ex2 Universal Temperature Conve…
Industrial Computers Tab-Ex 05 DZ1 WWAN Hazardous Area Tablet, Smart-Ex® 03 DZ2 smartphone for Zone 2/2…
Inductive Proximity Sensors NJ2-12GK-SN NAMUR Inductive Sensor
Power Modules PS1000-A6-24.20 Power Supply 24 VDC 20 A
Photoelectric Sensors R101 Retro-Reflective Photoelectric Sensor
Laser Distance, LiDAR & Radar Sensors R2000 2-D LiDAR Laser Scanner

Ordering Pepperl+Fuchs parts: what we need

Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.

Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.

FAQ

Questions about the Pepperl+Fuchs KFD2-STC4-Ex2 2-Channel Transmitter

Answers from our engineering team on installation, compatibility and integration.

01How many channels does KFD2-STC4-Ex2 provide?
It provides two isolated channels for 2-wire SMART transmitters in a 20 mm housing.
02What supply voltage does KFD2-STC4-Ex2 need?
The rated supply voltage is 20 to 35 V DC on terminals 14+ and 15-, with a consumption of up to 2.7 W.
03What load can each output of KFD2-STC4-Ex2 drive?
Each output drives 0 to 550 ohm at 20 mA, with overload detection above 25 mA.
04Is HART communication possible with KFD2-STC4-Ex2?
Yes. Digital signals are transferred bi-directionally, and an internal 250 ohm resistor is available between terminals 8 and 9 and between 11 and 12.
05Which ATEX certificate covers KFD2-STC4-Ex2?
The datasheet lists EU-type examination certificate BAS 99 ATEX 7025 X.