Brand:

Beamex 8129710 Accessory Holder for MC6-T150

Description

Beamex 8129710 accessory holder for the MC6-T150

Beamex 8129710 is a stainless steel accessory holder, painted black, that fixes to the back of an MC6-T150 temperature calibrator. While you carry the calibrator out to the plant it keeps loose items attached to the instrument itself: two inserts with their insulation shields, the insert removal tool and the power cord. That solves a small but constant problem of dry block calibration, namely that the inserts, which are hot after use and easy to lose, travel separately from the block. If the holder is ordered together with an MC6-T150 it is attached at the factory.

MC6-T150 facts that frame the 8129710 holder

Item MC6-T150 value
Temperature range -30 to 150 degrees C
Heating time 23 to 150 degrees C in 19 min; -30 to 150 degrees C in 23 min
Cooling time 150 to 23 degrees C in 17 min; 23 to -30 degrees C in 23 min; 150 to -30 degrees C in 37 min
Immersion depth 150 mm
Outer dimension (brochure) 30 mm
Weight 9.4 kg
Dimensions (D x W x H) 322 x 180 x 298 mm
Power 380 W, 115 V or 230 V
Control Dual zone heating and cooling

The brochure lists the Accessory holder for MC6-T150 among the optional accessories.

What 8129710 holds and how it is fitted

  • Two inserts, each protected by its insulation shield.
  • The insert removal tool that is part of the standard MC6-T accessories.
  • The mains power cord, wound around the holder for transport.

If the holder is ordered with an MC6-T150, Beamex attaches it to the calibrator in the factory. If it is ordered separately, as with the 8129710 listing, the assembly instructions are in the MC6-T user manual.

Why two inserts: planning the 8129710 loadout

The MC6-T150 uses interchangeable inserts with drilled holes for different probe diameters, and a dedicated insert for short sanitary and flanged sensors used in food and pharmaceutical plants. A technician often needs one insert for the sensor diameters on today’s route and another for a different sensor size. Because the 8129710 stores two, you can match them to the route and avoid reaching back into the vehicle. Insulation shields for inserts are listed by Beamex as separate items.

The MC6-T150 behind the 8129710 holder

The holder only makes sense in the light of the instrument it serves. The MC6-T150 is a multifunction device: besides its dry block it is an electrical calibrator, a pressure calibrator through its barometric module and external EXT pressure modules, and a multibus communicator. Its dual zone heating and cooling compensates for the heat loss caused by sensors installed in the insert, and the stability function follows the two sigma deviation of the readings so that only stable values are accepted. The accuracy figures quoted by Beamex include a display uncertainty of plus or minus 0.15 degrees C with the internal reference, stability of plus or minus 0.01 degrees C, and radial uniformity of plus or minus 0.01 degrees C, so what you carry in the 8129710 holder are the means of reaching those figures in practice: the right insert for the sensor diameter.

Using the 8129710 safely in the field

The MC6-T150 signals a hot block with a red light and a message on the screen, and the 8129710 holder is for carrying, not for storing hot inserts: let inserts cool, shield them and only then place them in the holder. The standard accessories include the insert removal tool so that inserts can be lifted without touching them. The holder does not change the thermal behaviour of the calibration block, since it is mounted at the back.

How 8129710 differs from 8129720

The holder for the MC6-T660 (8129720) is a different kit: it carries three inserts instead of two, comes with a sensor heat shield plate with mounting support for work above 150 degrees C. The 8129710 for the MC6-T150 needs no heat shield since the block never exceeds 150 degrees C. The two holders are therefore not interchangeable, and you should order according to the calibrator model.

Ordering notes and compatibility for 8129710

Specify 8129710 when the calibrator is an MC6-T150 and mention if it is to be fitted at the same time as a new calibrator order; in that case the manufacturer can attach it in the factory. For a calibrator already in the field, the user manual gives the assembly steps. After fitting, confirm that you can still reach the controls and the power connection. The spare fuses for the MC6-T150 are a separate item with order code 8129780.

Calibration teams in Oman and the GCC

Field crews in food and beverage, pharmaceutical and utility plants use the MC6-T150 for RTD and thermowell checks, and the 8129710 keeps their kit together on long walks between process units. Because Beamex designed the MC6-T150 to calibrate short and flanged sanitary sensors with a dedicated insert and a very short reference sensor on a flexible cable, the extra insert carried in the holder is often exactly that sanitary one. Plants in the region that supply drinking water, dairy products or pharmaceuticals therefore get a tidy way to transport it. For hot climates, remember that the operating temperature specification of the MC6-T is 0 to 45 degrees C so avoid leaving the case in a closed vehicle.

Documents and quotation

The MC6-T brochure lists the holder among the optional accessories. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with Beamex 8129710, the quantity and the serial or model of the MC6-T150 it will be fitted to.

Other Models in the Beamex Mc6 T Accessory Range

Seven Star LLC supplies models from the Beamex Mc6 T Accessory range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Beamex 8129720 Accessory Holder and Heat Shield MC6-T660Process, Pressure & Temperature CalibratorsView details
Beamex 8129710 Accessory Holder for MC6-T150Process, Pressure & Temperature CalibratorsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Beamex 8129710 Accessory Holder for MC6-T150 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.

Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.

Beamex company profile

Origin Founded in 1975 in Finland by four calibration technicians; first factory 1977
Headquarters Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992
Product families MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software
Typical duty Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters

Milestones

  • 1975: Four calibration technicians found the company in Finland.
  • 1977: The first factory opens.
  • 1992: ISO 9001 certification.

Beamex calibrators and accessories

Model Type Typical use
MC6 Advanced field calibrator and communicator Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results
MC6-Ex Intrinsically safe field calibrator Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit
MC6-T Temperature calibrator with integrated dry block Temperature sensors and transmitters, with multifunction electrical and pressure measurement
MC4, MC2 Documenting and hand-held process calibrators Routine loop, transmitter and switch checks in the field
FB, MB Field and metrology temperature dry blocks FB for field calibration; MB for higher-accuracy workshop and laboratory work
ePG, POC8 Electric pressure pump and automatic pressure controller Automated pressure calibration; POC8 for workshop calibration benches
PGC, PGM, PGL, PGPH, PGHH Hand pressure pumps Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH)
EXT modules External pressure modules Extending MC calibrators to additional ranges, 70 kPa to 100 MPa

Where Beamex equipment is used

Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.

Ordering Beamex equipment: what we need

State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.

Facts checked against Beamex company history and product information, October 2026.

FAQ

Questions about the Beamex 8129710 Accessory Holder for MC6-T150

Answers from our engineering team on installation, compatibility and integration.

01Which calibrator does Beamex 8129710 fit?
It fits the back of the MC6-T150 temperature calibrator, which generates -30 to 150 degrees C.
02What does the 8129710 holder carry?
Two inserts with their insulation shields, the insert removal tool and the power cord.
03Is the 8129710 holder painted?
It is made of stainless steel and painted black, according to the Beamex description.
04How is 8129710 installed when ordered separately?
The assembly instructions are in the MC6-T user manual; if ordered with the calibrator, Beamex fits it at the factory.
05Does 8129710 include a heat shield?
No. The heat shield belongs to the MC6-T660 holder 8129720, which is meant for work above 150 degrees C.