Beamex 9021115 ePG electric pressure pump kit overview

The Beamex ePG complete kit, order code 9021115, is a portable, battery-operated electric pressure pump and controller for industrial pressure calibration from -0.85 to 20 bar (-12.4 to 300 psi). It generates pressure or vacuum at the touch of a button and can be used with any existing pressure calibrator.

Beamex notes that using the ePG together with MC6 family calibrators makes pressure calibrations fully automatic. The pump is field-ready, water and dust resistant, and the battery pack can be replaced in the field.

This page describes Beamex 9021115 for buyers who need the exact order code. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Key features of the ePG electric pressure pump kit

  • Electric pressure and vacuum generation from -0.85 to 20 bar
  • Backlit coarse and fine adjustment buttons for setpoint control
  • Works with any pressure calibrator, fully automatic with MC6 family calibrators
  • Field-replaceable Li-ion battery pack with status indication
  • Water and dust resistant housing, hand and shoulder straps installed
  • Complete kit packed in a hard case

Standard delivery and contents according to Beamex:

  • ePG electric pressure pump and controller with hand and shoulder straps installed
  • Li-ion battery pack, installed
  • USB Type-C charger with country-specific mains plug
  • USB Type-A to Type-C communication cable
  • 40 bar pressure T-hose set 1.5 m with fittings and seals 8009550
  • Pressure plug set Bx G1/8 male and female 8003610
  • USB Type-C dust covers (5 pcs)
  • User manual
  • Hard case 8003360

Technical specifications of Beamex 9021115

Order code 9021115 (complete kit)
Pressure range -0.85 to 20 bar / -12.4 to 300 psi
Setpoint adjustability less than 10 mbar (0.15 psi)
Generation time 0 to 20 bar less than 110 s for a connected volume of up to 20 ml
Generation time 0 to -0.85 bar less than 45 s for a connected volume of up to 20 ml
Pressure port G1/8 female (ISO 228/1), adapter for Beamex low pressure hose included
Filter element 36 micron, in the pressure port
Pressure medium Clean dry non-corrosive gas
Dimensions 231 x 157 x 62 mm (without removable connector)
Weight about 2.3 kg
Battery Li-ion pack, 14.4 V, USB-C connector
Charger USB Type-C, Power Delivery Profile 4, 20 V
Operating temperature 0 to 50 C
Storage temperature -20 to 60 C
Warranty 1 year

All values are taken from Beamex documentation. Items not shown here are not stated in the manufacturer source and are therefore left out.

Typical applications in Oman and the GCC

Pressure calibration is a routine task wherever transmitters, gauges and switches protect a process. In oil and gas facilities, gas treatment plants, power and desalination stations, water networks and manufacturing sites around Oman and the GCC, instrument teams use a calibration pump to create a known pressure so that the reading of the device under test can be compared with a reference.

The ePG electric pressure pump kit (9021115) suits instrument workshops, plant maintenance crews and metrology laboratories that need a dependable pressure source next to a reference module or documenting calibrator. Because heat and dust are common in the region, a pump that is simple to operate and easy to service helps keep calibration intervals on schedule.

Selection and compatibility notes for 9021115

Start with the pressure range and the medium. Match the maximum output of 9021115 to the highest range of the instruments you calibrate, and confirm that the medium used by the pump is acceptable for the device under test. Never connect a reference module or instrument with a lower rating than the pressure the pump can reach.

Check the thread types on both sides before ordering. Beamex publishes a fittings guide and lists many adapters and hoses separately, so a pump usually needs a matching fitting for each device under test. When the instruments in your plant use mixed BSP and NPT threads, plan an adapter set at the same time as the pump.

Installation and commissioning

Place the pump on a stable surface or hold it as the manual describes, then connect the reference and the device under test with suitable fittings and hoses. Check that seals are present and clean before tightening, and use only fittings rated for the full pressure of the application.

Raise the pressure slowly, watch the reference reading, and use the fine adjustment to settle on each test point. Release pressure through the vent or release control before disconnecting anything. Follow the safety notes in the Beamex manual for 9021115.

Maintenance and care

Keep ports and fittings clean and store the pump in its case when it is not in use. Dirt, moisture and unsuitable fluids are the most frequent causes of seal wear in any calibration pump, so protect the pump from contamination coming from the device under test.

Seals and O-rings are consumables. Beamex catalogues service and spare parts sets for its pumps, so a small spare stock lets a workshop repair a pump quickly and keep calibration work moving.

Related products and ordering notes

Beamex lists these related items, each with its own order code:

  • 8006130 ePG piston seal service kit
  • 8006145 ePG non-return valve kit
  • 8003355 hard case for ePG and MC6
  • 8006030 battery pack ePG, Li-ion

Beamex is a Finnish maker of calibration equipment, and its manuals and product pages are the reference for every figure on this page. Always check the manufacturer’s current documentation before putting any accessory or spare part into service.

Seven Star LLC works with industrial maintenance, procurement and calibration teams, so requests that include the full order code, the quantity and the delivery location can be answered quickly. Order codes are often the only reliable way to separate similar-looking accessories from different product generations.

Plants in the region usually plan calibration work around shutdowns, turnarounds and seasonal maintenance windows. Ordering accessories and spare parts well before the work starts avoids waiting for a missing seal, hose or cable when the plant is already offline, and it is cheaper than expediting a single item at the last minute.

Good calibration practice also depends on traceability. Records of the reference equipment, its certificate, the environmental conditions and the as-found and as-left results are what auditors and clients ask for. Accessories do not replace the calibration of the reference itself, but a worn hose, a leaking seal or a damaged cable can spoil an otherwise good measurement, which is why consumables should be replaced on a schedule rather than only after a failure.

When you compare quotations, make sure the order code is identical. Calibration accessories from the same manufacturer often differ only by thread, length or pressure rating, and a similar-looking item with a different code may not be compatible with your equipment. Keep the code on the purchase order, the goods receipt note and the maintenance record so that the same item can be reordered later.

Frequently asked questions about 9021115

What range does the ePG kit 9021115 cover? It covers -0.85 to 20 bar (-12.4 to 300 psi) and can generate both pressure and vacuum, according to the Beamex ePG brochure.

Can it be used with calibrators other than Beamex? Yes. Beamex states that the ePG can be used with any existing pressure calibrator, and it becomes fully automatic when paired with an MC6 family calibrator.

What is in the complete kit? The ePG with straps, installed Li-ion battery, USB-C charger, USB cable, 40 bar T-hose set 8009550, plug set 8003610, dust covers, manual and hard case 8003360.

Which media can the ePG use? Clean dry non-corrosive gas only. The wetted parts are aluminum, brass, stainless steel, thermoplastic polyester and food grade LMS oil.

Can the user service the pump? Yes. Beamex says common maintenance can be done by the user, and lists a piston seal service kit 8006130 and a non-return valve kit 8006145.

Documents and quotation

The manufacturer datasheet for Beamex 9021115 is attached to this page as a PDF. To request a quotation, send the RFQ with part number 9021115, the quantity, and the delivery location in Oman or the GCC. Our team will confirm availability and lead time.

Quote Beamex 9021115 exactly as written when you contact us, so that the correct item is quoted the first time. Delivery to Oman and to other GCC countries is arranged for each order, and any questions about packaging, documentation or alternative items can be raised in the same message.

Datasheets & Documents
  • PDF Datasheet Beamex 9021115 ePG Electric Pressure Pump and Controller Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.

Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.

Beamex company profile

Origin Founded in 1975 in Finland by four calibration technicians; first factory 1977
Headquarters Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992
Product families MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software
Typical duty Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters

Milestones

  • 1975: Four calibration technicians found the company in Finland.
  • 1977: The first factory opens.
  • 1992: ISO 9001 certification.

Beamex calibrators and accessories

Model Type Typical use
MC6 Advanced field calibrator and communicator Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results
MC6-Ex Intrinsically safe field calibrator Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit
MC6-T Temperature calibrator with integrated dry block Temperature sensors and transmitters, with multifunction electrical and pressure measurement
MC4, MC2 Documenting and hand-held process calibrators Routine loop, transmitter and switch checks in the field
FB, MB Field and metrology temperature dry blocks FB for field calibration; MB for higher-accuracy workshop and laboratory work
ePG, POC8 Electric pressure pump and automatic pressure controller Automated pressure calibration; POC8 for workshop calibration benches
PGC, PGM, PGL, PGPH, PGHH Hand pressure pumps Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH)
EXT modules External pressure modules Extending MC calibrators to additional ranges, 70 kPa to 100 MPa

Where Beamex equipment is used

Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.

Ordering Beamex equipment: what we need

State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.

Facts checked against Beamex company history and product information, October 2026.

FAQ

Questions about the Beamex 9021115 ePG Electric Pressure Pump and

Answers from our engineering team on installation, compatibility and integration.

01What range does the ePG kit 9021115 cover?
It covers -0.85 to 20 bar (-12.4 to 300 psi) and can generate both pressure and vacuum, according to the Beamex ePG brochure.
02Can it be used with calibrators other than Beamex?
Yes. Beamex states that the ePG can be used with any existing pressure calibrator, and it becomes fully automatic when paired with an MC6 family calibrator.
03What is in the complete kit?
The ePG with straps, installed Li-ion battery, USB-C charger, USB cable, 40 bar T-hose set 8009550, plug set 8003610, dust covers, manual and hard case 8003360.
04Which media can the ePG use?
Clean dry non-corrosive gas only. The wetted parts are aluminum, brass, stainless steel, thermoplastic polyester and food grade LMS oil.
05Can the user service the pump?
Yes. Beamex says common maintenance can be done by the user, and lists a piston seal service kit 8006130 and a non-return valve kit 8006145.