FCT/PRG/PRG/U/-RF [DIN] Signal Converter/Isolator

Description

Moore FCT/PRG/PRG/U/-RF [DIN] overview

The Moore FCT/PRG/PRG/U/-RF [DIN] is a four-wire, field-configurable signal converter and isolator from Moore Industries that can act as an isolator, converter or repeater. The universal PRG input and output let the user select common signal types such as 4-20 mA, 1-5 V and 0-10 V in the field.

The -RF option increases RFI and EMI immunity to 30 V/m for noisy environments. Transmitter excitation is standard on universal PRG input and output units, so a two-wire transmitter can be powered directly.

The part number FCT/PRG/PRG/U/-RF [DIN] follows the ordering pattern of the manufacturer datasheet, which lists the fields in this order: unit, input, output, power, options and housing (Unit / Input / Output / Power / Options [Housing]). The string written as FCT/PRG/PRG/U/-RF [DIN] is the model example printed in that datasheet, so it describes one complete configuration. If your plant needs a different input, output, supply, option or housing, send the configuration with your RFQ and it will be checked against the ordering table.

  • FCT: field-configurable signal converter and isolator
  • PRG: universal programmable input
  • PRG: universal programmable output
  • U: universal ac/dc power input
  • -RF: enhanced RFI/EMI protection
  • [DIN]: DIN-style housing

Key features of the Moore Industries FCT/PRG/PRG/U/-RF [DIN]

  • Configurable inputs and outputs for common signal types.
  • Universal power input: 90-260 Vac and 22-300 Vdc without jumper changes.
  • Isolation of 1000 Vrms stops ground loops (500 Vac with the -RF option).
  • Transmitter excitation is standard on universal units.
  • -RF option gives 30 V/m RFI/EMI protection, against 10 V/m inherent.
  • CSA general location and City of Los Angeles approvals.

Technical specifications for FCT/PRG/PRG/U/-RF [DIN]

Parameter Value
Model string Moore FCT/PRG/PRG/U/-RF [DIN]
Accuracy plus or minus 0.1% of span, including adjustment resolution and linearity
Isolation 1000 Vrms between input, output and power (500 Vac with -RF)
Dielectric withstand 1500 Vrms between case, power, inputs and outputs (500 Vac with -RF)
Frequency response 5 Hz at the -3 dB point
Ripple 10 mV peak-to-peak at maximum span and maximum load
Power 90-260 Vac or 22-300 Vdc
RFI/EMI immunity 10 V/m standard; 30 V/m with -RF

The values above come from the manufacturer datasheet for the FCT family. Specifications can differ by input type and option, so read the matching page of the datasheet before finalising a purchase specification and keep the complete model string on your purchase documents. Where a value is not listed here it was not stated clearly enough in the datasheet to repeat.

Typical applications of the FCT/PRG/PRG/U/-RF [DIN] in Oman and the GCC

It is often used where a DCS or PLC input needs a different signal type from the transmitter, such as 4-20 mA to 0-10 V.

In oil and gas, petrochemical and power plants, isolators and converters like the FCT/PRG/PRG/U/-RF [DIN] are used between field transmitters and DCS, PLC or recorder inputs to break ground loops and to protect expensive input cards from surges and noise.

Water treatment, desalination and wastewater plants often have long cable runs between remote pump stations and the control room, which makes galvanic isolation valuable. Manufacturing plants use the same function to interface instruments from different suppliers that expect different signal types.

One configurable unit such as the FCT/PRG/PRG/U/-RF [DIN] can serve as a spare for several signal types, which simplifies stores for sites in Oman and the GCC where delivery from overseas takes time.

Selection and compatibility notes for FCT/PRG/PRG/U/-RF [DIN]

The datasheet lists a wide range of non-standard input and output types for uncommon interfaces; for a fixed non-universal type, confirm the field of the model string against the ordering table.

Match the signal types and the power scheme to the application. Loop-powered and line-powered isolators are wired differently, and the supply field of the part number tells you which one you are buying.

Check the required accuracy, response time and the load the output must drive against the datasheet values, and check whether the application also needs HART communication, because not every isolator in the catalog passes HART signals.

If you are replacing an installed unit, send the model string from its nameplate with the RFQ so that input, output, supply, option and housing can be compared field by field against the ordering table.

Installation and commissioning

Snap the FCT/PRG/PRG/U/-RF [DIN] onto its rail or fit it in the supplied housing, leaving ventilation space around it when many units are mounted side by side. Follow the terminal drawing in the manufacturer manual for supply, input and output wiring.

Use shielded twisted-pair cable for signal runs and ground the shield at one end only, following your plant practice. Keep signal wiring away from power cables and variable speed drive output cables.

After wiring, apply power, simulate the input at zero, mid and full scale, and confirm the output on a calibrated meter. Where front-panel zero and span adjustment is provided, make trim adjustments in small steps and record the final values.

Maintenance and spares

Isolators and converters are normally maintenance-free apart from periodic loop checks. During plant shutdowns, check terminals for tightness and corrosion, clean dust from the housing, and verify the input to output relationship at a few points.

Keep at least one spare of each model string in store and note the full part number on your spares list; a small difference in a field of the string can mean a different input, output or supply.

Related products and ordering notes

Related isolator families from the same manufacturer are the SIX, SSX and ECT. The datasheet is available on request.

Unit and accessory part numbers such as those named above are separate line items. Please list each one with its quantity so that the quotation covers the complete package. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Frequently asked questions about FCT/PRG/PRG/U/-RF [DIN]

  • What does the FCT/PRG/PRG/U/-RF [DIN] do? It isolates, converts or repeats process signals, with input and output types selected in the field.
  • What power does the FCT/PRG/PRG/U/-RF [DIN] accept? It accepts 90-260 Vac and 22-300 Vdc automatically.
  • What isolation does the FCT/PRG/PRG/U/-RF [DIN] provide? 1000 Vrms normally, and 500 Vac for units with the -RF option.
  • What does -RF add on the FCT/PRG/PRG/U/-RF [DIN]? Increased RFI/EMI protection of 30 V/m instead of 10 V/m.
  • How do I order the FCT/PRG/PRG/U/-RF [DIN]? Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.

Documents and quotation

The manufacturer datasheet for the FCT family is available from us on request and a copy is attached to this page. It contains the full ordering table, specifications and dimension drawings, and we suggest reading it before you decide on the final configuration.

To request a quotation, send an RFQ that includes the part number FCT/PRG/PRG/U/-RF [DIN], the quantity, the delivery location in Oman or the GCC and any special requirement such as certification documents or a required delivery date. Our team will confirm availability and lead time and reply with a written offer.

Datasheets & Documents
  • PDF Datasheet FCT Field-Configurable Signal Converter/Isolator Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.

Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.

Moore Industries company profile

Founded 1968, North Hills, California, USA, by Leonard W. Moore
Headquarters North Hills, California, since 1974
Ownership Privately owned (Moore Industries-International, Inc.)
First product SCT signal converter
Product families Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA)

Milestones

  • 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
  • 1974: The company moves into its North Hills headquarters.
  • 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.

Moore Industries product families on this page

The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:

  • Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
  • Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
  • Signal isolators, repeaters and converters: the SIX
  • PID controllers and backup stations: the 535 in 1/4 DIN format

Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.

Where Moore Industries instruments are used

These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.

Moore Industries products we list

Family Examples
Controllers & Data Acquisition Moore 535-21120BD000 | Industrial PID Ba…, SPA2 Programmable Limit Alarm Trip, Moore-SPA2HL Associated IS Programmable…
Isolator & Barrier HIM Smart HART Loop Interface and Monitor, SIX Signal Isolator, SLA SIL 2/3 Safety Logic Solver and Alarm
Temperature Instrumentation STZ Functional Safety Dual Input Smart H…, TRX Temperature Transmitter
Industrial Communications HES HART to Ethernet Gateway
Valve Positioners IPT2 Current-to-Pressure I/P Transmitter

Ordering Moore Industries instruments: what we need

Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.

Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.

FAQ

Questions about the FCT/PRG/PRG/U/-RF [DIN] Signal Converter/Isolator

Answers from our engineering team on installation, compatibility and integration.

01What does the FCT/PRG/PRG/U/-RF [DIN] do?
It isolates, converts or repeats process signals, with input and output types selected in the field.
02What power does the FCT/PRG/PRG/U/-RF [DIN] accept?
It accepts 90-260 Vac and 22-300 Vdc automatically.
03What isolation does the FCT/PRG/PRG/U/-RF [DIN] provide?
1000 Vrms normally, and 500 Vac for units with the -RF option.
04What does -RF add on the FCT/PRG/PRG/U/-RF [DIN]?
Increased RFI/EMI protection of 30 V/m instead of 10 V/m.
05How do I order the FCT/PRG/PRG/U/-RF [DIN]?
Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.