Phoenix Contact MACX MCR-T-UIREL-UP Temperature Transducer

Description

MACX MCR-T-UIREL-UP: programmable temperature transducer with relays

The MACX MCR-T-UIREL-UP is a one-channel temperature measuring transducer that accepts resistance thermometers in 2-, 3- or 4-wire connection as well as thermocouples. It gives a current output and has three limit-value relays, with a wide-range supply of 24 to 230 V AC/DC. The page lists SIL 2 under IEC 61508, Performance Level d and Systematic Capability 2. Seven Star LLC supplies the MACX MCR-T-UIREL-UP in Oman and the GCC as an independent supplier in Muscat.

The name shows the family MACX MCR, T for temperature, UIREL for universal input with relay outputs and UP for the universal power supply. Order number 2811378 is the standard configuration with 4-way isolation.

Technical specifications of the MACX MCR-T-UIREL-UP

Parameter Specification
Manufacturer / part number Phoenix Contact MACX MCR-T-UIREL-UP (order no. 2811378)
Function Programmable temperature transducer, 1 channel
Input sensors (RTD) Pt, Ni and Cu sensors, 2-, 3- or 4-wire
Input sensors (thermocouple) Types B, E, J, K, N, R, S, T, L, U and further listed types
Outputs Analogue current output and 3 limit-value relays
Current output 0 to 20 mA (SIL function off); max. 22 mA
Supply voltage 24 to 230 V AC/DC, -20 % to +10 % (19.2 to 253 V AC/DC), 50/60 Hz
Configuration DIP switches
Maximum transmission error 0.1 % (e.g. Pt 100, 300 K span, 4 to 20 mA)
Temperature coefficient Max. 0.01 %/K
Isolation 4-way isolation; rated insulation voltage 300 Vrms; test voltage 2.5 kV AC (50 Hz, 60 s)
Safety data SIL 2 (IEC 61508), PL d (ISO 13849), Systematic Capability 2
Ambient temperature -20 to 65 °C, with reduced limits at higher altitude
Dimensions 35 x 112.5 x 113.7 mm (W x H x D)

How the MACX MCR-T-UIREL-UP processes a temperature signal

The transducer measures the sensor signal, linearises it according to the selected sensor type and gives an output proportional to temperature. For resistance thermometers it supports 2-, 3- and 4-wire connection, which allows cable resistance compensation for long leads. For thermocouples it performs reference junction compensation in the device so that cold-junction effects are corrected.

Three relays act as limit switches for alarms or shutdown, so the signal can be used directly in local protection without an extra relay module. Isolation between input, output, relay outputs and supply stops ground loops and shields the PLC from faults.

Where the MACX MCR-T-UIREL-UP fits in an instrument loop

It sits in the control cabinet between the temperature sensor in the field and the analogue input of the PLC or DCS. The universal supply from 24 V up to 230 V AC/DC makes the same device usable in plants with different auxiliary supplies, so a single spare covers many cabinets.

Compared with the MACX MCR-SL-CAC-5-I that measures AC current, this device is for temperature and for use with safety functions up to the stated safety level.

Selection and ordering checklist for the MACX MCR-T-UIREL-UP

  • Sensor type: Pt, Ni, Cu or thermocouple type, and number of wires.
  • Measuring span and output standard.
  • Relay functions needed for limit values.
  • Supply voltage available: 24 to 230 V AC/DC.
  • Safety function requirement: SIL 2 information from the manual.
  • Ambient temperature and altitude of the installation.

Installation, commissioning and maintenance of the MACX MCR-T-UIREL-UP

Mount the module on a DIN rail and connect the sensor, the supply, the analogue output and the relay contacts. Configure with the DIP switches according to the sensor and output required, and check against the manual before powering up.

Verify the loop by simulating the sensor with a calibrator. For safety loops, perform proof tests as defined in the safety manual and keep the results in the plant records.

Typical applications in Oman and the GCC

In Oman and the GCC, temperature transducers with relays are used on furnaces, bearing temperature monitoring, process heaters and heat exchangers, where a local alarm and a standard analogue signal are both needed. Operation up to 65 °C suits hot cabinets.

The universal power supply simplifies stocking for sites with mixed 24 V DC and 230 V AC auxiliary supplies.

When setting relay limits, allow for sensor drift and process noise: set the alarm a little below the true danger value, and use the relay for local annunciation while the analogue output carries the continuous reading to the control system. Document each limit value, the relay used and the action it triggers. For a safety loop, never alter the DIP-switch settings without following the change procedure, and repeat the proof test after any modification of the configuration. Keep the manual and the configuration record with the loop folder so that a replacement unit can be set identically.

Comparison with related devices

Device Distinguishing data
MACX MCR-T-UIREL-UP (this part) Temperature, RTD/TC, 3 relays, SIL 2 data
MACX MCR-SL-CAC-5-I AC current transducer
MACX MCR-T-UI-UP Temperature transducer without relays
KFD2-UT2-Ex1 Intrinsically safe temperature converter

Information to send with an RFQ for the MACX MCR-T-UIREL-UP

  • Part number MACX MCR-T-UIREL-UP and quantity.
  • Sensor type and temperature range.
  • Relay setpoints needed.
  • Supply voltage.
  • Safety requirement.

Site conditions in Oman for the MACX MCR-T-UIREL-UP

Control cabinets in Gulf plants often run hot, because many sit in outdoor kiosks or in rooms where air conditioning is not always reliable. Before you finalise the MACX MCR-T-UIREL-UP, check the permitted ambient range and any derating stated by the manufacturer against the real temperature inside your panel, and leave the recommended spacing around the device so that heat can escape. Long cable runs between the field and the marshalling cabinet are common on large sites, so confirm the signal types, wiring limits and earthing arrangement early in the design.

It also helps to standardise on a small number of part numbers across a project. Keeping a few spare MACX MCR-T-UIREL-UP units on site in Oman shortens recovery time after a fault, and documenting configuration settings makes replacement faster for the maintenance team.

Documents and quotation

The Phoenix Contact data sheet for the Phoenix Contact MACX MCR-T-UIREL-UP temperature transducer (item 2811378, English) is attached on this page as a PDF. It sets out the RTD, thermocouple, resistance and voltage inputs, the configurable current and voltage output, the limit-value relay, the wide-range power supply, the isolation and accuracy data, the connection details and the dimensions. Check the sensor type, the output signal and the relay function against your loop, then send us the quantity and the delivery location for a quotation.

Please also tell us the delivery location and the project timeline so that availability can be checked before you commit to a schedule.

Other Models in the Phoenix Macx Range

Seven Star LLC supplies models from the Phoenix Macx range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Phoenix Contact MACX MCR-SL-CAC-5-I AC Current TransducerIsolator & BarrierView details
Phoenix Contact MACX MCR-T-UIREL-UP Temperature TransducerIsolator & BarrierYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Phoenix Contact MACX MCR-T-UIREL-UP Data Sheet, 2811378 (PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Phoenix Contact is a German, family-owned manufacturer of electrical connection technology and industrial automation, founded in 1923 in Essen by Hugo Knümann. It began as a sales company, and in 1928 Knümann developed the modular terminal block mounted on a rail, the product the company is still best known for. Phoenix Contact is headquartered in Blomberg, North Rhine-Westphalia.

Seven Star LLC lists Phoenix Contact surge protection, power supplies and safety relays, and sources these components by order number for panel builders and maintenance teams in Oman.

Phoenix Contact company profile

Founded 1923, Essen, Germany, by Hugo Knümann, as Phönix Elektro- und Industrie-Bedarfsgesellschaft
Headquarters Blomberg, Germany
Ownership Family-owned (Eisert and Stührenberg families)
Key invention The modular terminal block on a DIN rail, 1928
Product families CLIPLINE terminal blocks, PCB terminals and connectors, QUINT and TRIO power supplies, relay modules, surge protection, signal conditioners, Ethernet switches and PLCnext controllers

Milestones

  • 1923: Hugo Knümann founds the company in Essen.
  • 1928: The first modular terminal block is developed.
  • Later: Headquarters move to Blomberg, Ostwestfalen-Lippe.

Phoenix Contact parts listed on this page

The TTC-6-2X1-24DC-UT (order number 2906799) is a surge protection device with screw connection for two 24 V DC signal wires that share a common reference potential. The QUINT-PS/1AC/24DC/10 is a single-phase DIN rail power supply delivering 24 V DC at 10 A. The PSR-SCP-24DC/ESP4/2X1/1X2 (order number 2981020) is a single-channel PSR safety relay for emergency stop and safety door monitoring, with two enabling current paths and plug-in screw terminals.

Phoenix Contact products we list

Family Examples
Isolator & Barrier 2906799 TTC-6-2X1-24DC-UT Surge Protector, MACX MCR-EX-SL-RPSSI-I Signal Isolator, MINI MCR-2-UI-UI 3-Way Signal Conditione…, PLT-SEC-T3-230-FM Type 3 Surge Protectio…
Power Modules QUINT-PS/1AC/24DC/10 QUINT Power Supply, QUINT4-PS/1AC/24DC/10 Power Supply, TRIO-PS-2G/1AC/24DC/10 Power Supply, UNO-PS/1AC/24DC/100W Power Supply
Automation Accessories PLC-RSC-24DC/21 Relay Module, PSR-SCP-24DC/ESP4/2X1/1X2 Safety Relay (…

Ordering Phoenix Contact components: what we need

Phoenix Contact items are ordered by a seven-digit order number together with the type designation, both printed on the side of the module. Send both, plus the quantity. If the number is unreadable, send the type text and a photo. For power supplies, state input voltage, output current and whether the unit runs in parallel or with a redundancy module. For buyers in the GCC replacing an older unit, we check the manufacturer's documentation for the listed successor type.

Facts checked against Phoenix Contact's own company history (phoenixcontact.com), October 2026.

FAQ

Questions about the Phoenix Contact MACX MCR-T-UIREL-UP Temperature

Answers from our engineering team on installation, compatibility and integration.

01Which sensors can it measure?
Pt, Ni and Cu resistance thermometers (2-, 3-, 4-wire) and many thermocouple types.
02What supply voltage is allowed?
24 to 230 V AC/DC, range 19.2 to 253 V AC/DC.
03How many relays?
Three limit-value relays.
04What accuracy?
Maximum transmission error 0.1 % for Pt 100 with a 300 K span at 4 to 20 mA.
05What safety data is listed?
SIL 2, PL d and Systematic Capability 2.