Brand: Pepperl+Fuchs
Pepperl+Fuchs KFD2-CRG2-Ex1.D Transmitter Power Supply with Relays
Description
Pepperl+Fuchs KFD2-CRG2-Ex1.D overview
The Pepperl+Fuchs KFD2-CRG2-Ex1.D is a one-channel isolated barrier from the K-System of Pepperl+Fuchs that supplies 2-wire and 3-wire transmitters in a hazardous area and can also be used with 2-wire current sources. Two relays and an active 0/4 to 20 mA current source are available as outputs, and the relay contacts and the current output can be integrated into safety-relevant circuits.
The datasheet released on 13 October 2025 describes adjustable energized and de-energized delays, programmable high and low alarms, a linearization function with up to 20 points and a display that can show the measured value in various physical units. The device is configured with the keypad or with PACTware, and the input has line fault detection.
Key features of the Pepperl+Fuchs KFD2-CRG2-Ex1.D
- Supplies 2-wire and 3-wire transmitters and accepts 2-wire current sources
- Two relay outputs and one active 0/4 to 20 mA output
- Adjustable energized and de-energized delay of 0 to 250 s
- Programmable high and low alarm and linearization with up to 20 points
- Line fault detection and a separate collective error message output
- Configuration by keypad or PACTware through a programming socket
- Up to SIL 2 according to IEC/EN 61508 and IEC/EN 61511
- Powered from 20 to 30 V DC via Power Rail or terminals 23 and 24
KFD2-CRG2-Ex1.D technical specifications
The values below are taken from the manufacturer datasheet of the KFD2-CRG2-Ex1.D, release date 2025-10-13. Always confirm the current datasheet and the certificates before final engineering.
| Parameter | Value |
|---|---|
| Model | KFD2-CRG2-Ex1.D, Transmitter Power Supply, 1-channel isolated barrier |
| Signal type | Analog input |
| Safety integrity | SIL 2 |
| Supply | 20 to 30 V DC, Power Rail or terminals 23+, 24- |
| Rated current | About 130 mA |
| Power dissipation / consumption | 2 W / 2.5 W |
| Input | 0/4 to 20 mA; available voltage at least 15 V at 20 mA; input resistance 45 ohm (terminals 2, 3) |
| Line fault detection | Breakage below 0.2 mA; short-circuit above 22 mA |
| Relay outputs I and II | 253 V AC / 2 A / cos phi at least 0.7; 40 V DC / 2 A |
| Analog output III | 0 to 20 mA or 4 to 20 mA, load up to 650 ohm, open loop voltage up to 24 V DC |
| Fault signal | Downscale 3.6 mA or less, upscale 21 mA or more (NAMUR NE43) |
| Accuracy, output III | Less than 20 microamperes |
| Ambient temperature | Minus 20 to 60 degrees C |
| Dimensions / mass | 40 x 119 x 115 mm (W x H x D), housing type C2 / 300 g |
| Mounting | 35 mm DIN rail according to EN 60715 |
The hazardous-area parameters are listed per terminal pair in the datasheet. Use the entity values of the exact terminals you wire, and refer to the certificate for the permitted cable parameters of your installation.
Typical applications in oil and gas, utilities, water and manufacturing
Many hazardous-area measurements need more than a simple repeater: temperature sensors, load cells and HART devices all need conditioning, scaling or trip alarms close to the signal source. The KFD2-CRG2-Ex1.D combines the intrinsically safe interface with that processing in a single K-System module, which keeps cabinets compact.
In refineries, gas plants, power stations, water works and manufacturing sites in Oman and the GCC, such modules are used on furnace and bearing temperatures, tank weighing, batching and loop monitoring. Configuration through the keypad or PACTware allows technicians to set ranges, alarms and fault behaviour without rewiring.
Selection and compatibility notes for KFD2-CRG2-Ex1.D
Confirm that the input and output types of the KFD2-CRG2-Ex1.D match your loop. The datasheet lists the accepted sensor types, ranges and output signals, and any output that is not intrinsically safe must be wired in the safe area. Check the supply method and the housing width against your cabinet layout.
Check the relay or analog output against the receiving device, and decide how you will configure the module. If you need a different input type, number of outputs or functional safety level, send us your loop data and we will compare neighbouring variants against the KFD2-CRG2-Ex1.D.
Installation and commissioning of the KFD2-CRG2-Ex1.D
Before mounting the KFD2-CRG2-Ex1.D, confirm the field device and cable parameters against the entity values in the datasheet and the certificate, and decide whether the module will be powered from a Power Rail, a termination board or its own supply terminals. Mount it in a clean, ventilated cabinet in the safe area, keep hazardous-area and safe-area wiring physically separated and labelled, and respect the spacing and marking required by your site rules for intrinsically safe circuits.
Wire the KFD2-CRG2-Ex1.D only to the terminal assignment printed in the wiring diagram, tighten the screws and check that no strands are left outside the clamp. After applying the supply, check the power indication, then simulate the field signal and prove the complete loop from field to control system before the plant is handed over. Record the as-found readings so that later loop checks of the KFD2-CRG2-Ex1.D can be compared with the commissioning values.
Maintenance and service life
The KFD2-CRG2-Ex1.D has no serviceable parts, so maintenance is mostly inspection. During planned shutdowns, check terminals for looseness and corrosion, verify the supply voltage at the module, and repeat the loop check that was recorded at commissioning. In coastal and humid locations such as Muscat, Sohar and Duqm, a clean, dry and sealed cabinet greatly extends the life of any electronic interface.
If a loop drifts out of tolerance or the unit shows no power indication with a healthy supply, replace the module instead of attempting a repair, and keep the replacement documentation in the loop folder. Certified intrinsically safe equipment must not be modified, and any change to cabling, load or field device should be re-assessed against the KFD2-CRG2-Ex1.D entity parameters before it returns to service.
Related products and ordering notes
Customers who ask for the KFD2-CRG2-Ex1.D often need neighbouring models or accessories from the same system, such as other K-System isolated barriers, the Power Rail and power feed modules, KFA6 power supplies and the matching NAMUR sensors. If you are standardising a cabinet or a spare parts list on one family, send us the loop list or the equipment list and we can quote the matching items together.
When you send an enquiry for the KFD2-CRG2-Ex1.D, quote the full part number exactly as printed on the nameplate, the quantity and the intended application. If you are replacing an installed unit, a photograph of the nameplate helps us confirm the exact variant you need. We can arrange a quotation with delivery to Oman and across the GCC.
Frequently asked questions about KFD2-CRG2-Ex1.D
The KFD2-CRG2-Ex1.D is a SIL 2 capable transmitter power supply with two relay outputs, a 0/4 to 20 mA output, linearization, line fault detection and keypad or PACTware configuration in a 40 mm wide housing.
Documents and quotation
A copy of the manufacturer datasheet for the KFD2-CRG2-Ex1.D is attached to this page for your engineering review. To request a quotation, send the RFQ with the part number KFD2-CRG2-Ex1.D, the quantity, the delivery location and any certification or documentation requirements, and we will reply with availability and lead time. Please check the specification against your loop or system requirements before ordering.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with Pepperl+Fuchs. Product names and part numbers are used only to identify the item you ask for.
Datasheets & Documents
- Datasheet KFD2-CRG2-Ex1.D Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs KFD2-CRG2-Ex1.D Transmitter Power
Answers from our engineering team on installation, compatibility and integration.
01What outputs does the KFD2-CRG2-Ex1.D provide?
It provides two relay contact outputs and one active 0/4 to 20 mA current output, together with a collective error message output.
02How is the KFD2-CRG2-Ex1.D configured?
Configuration is done with the operating buttons on the front or with the PACTware configuration software through the programming socket.
03Which transmitters can it supply?
It supplies 2-wire and 3-wire transmitters and can also be used with 2-wire current sources, with at least 15 V available at 20 mA.
04Which documents are available for the KFD2-CRG2-Ex1.D?
The manufacturer datasheet is attached to this page, and certificates or manuals can be requested together with your RFQ for the KFD2-CRG2-Ex1.D.
05How do I order the KFD2-CRG2-Ex1.D?
Send an RFQ with the part number KFD2-CRG2-Ex1.D, the quantity and the delivery location in Oman or the GCC, and Seven Star LLC will reply with availability and lead time.