GESTRA IB 16A-7 Inverted Bucket Steam Trap for Universal Connector: overview

The GESTRA IB 16A-7 is an inverted bucket steam trap made of stainless steel, with an integral spiral wound gasket, for fitting to a universal swivel connector. Its orifice sits in the upper body and is controlled by the vertical movement of the inverted bucket. The datasheet describes it as very robust, unaffected by corrosion and with an excellent ability to handle dirt.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list the GESTRA IB 16A-7 for buyers who need an exact GESTRA type for a repair, a replacement or a new project and want a clear technical summary before they ask for a quotation. Everything below is condensed from the manufacturer datasheet, so you can compare the IB 16A-7 with the line conditions on your own drawings. Where a value is not stated in the datasheet, we leave it out rather than guess.

GESTRA equipment is common on steam and condensate systems, boiler houses and process plants, and many installed units in Omani and Gulf facilities are now several years old. That is why buyers often search by the exact type designation such as IB 16A-7. Matching the designation, nominal size, pressure rating and connection type is the surest way to get the right replacement, and our team can help check these details against the nameplate or the earlier project documentation before a quotation is issued.

Key features of the IB 16A-7

The datasheet describes the following points about the IB 16A-7. They explain why this inverted bucket steam trap is chosen for its duty and what to look for when comparing it with other options.

  • Stainless steel body 1.4306 / A240-304L.
  • Integral spiral wound gasket.
  • Ring flange supplied, attached to the universal connector with two hexagon-head cap screws.
  • Air is vented through the small hole in the top of the inverted bucket.
  • Designed for first installation or replacement on universal connectors of all types and makes.
  • Available with GESTRA UC 36, UCY 36 or the TrapStation TS 36.

Technical specifications of the IB 16A-7

The table below summarises the main data for the IB 16A-7 taken from the manufacturer datasheet. Always confirm the final pressure and temperature limits against the datasheet for the exact version and connection you plan to order, because ratings depend on connection type and size.

Parameter Value
Maximum operating pressure PMO 28 bar at 425 C (400 psig at 800 F)
Differential pressures 4.8, 8.6, 17.2, 27.6 bar depending on orifice
Body material 1.4306 / A240-304L
End connection Universal connectors of all types and makes
Rating basis ASME BPVC Section VIII/1 UG-101
Orifices Available for various differential pressures
Related connectors UC 36, UCY 36, TS 36-1, TS 36-2
Gasket Integral spiral wound
Ring flange Supplied, not fitted
Capacity Chart in datasheet

Typical applications in Oman and the GCC

The IB 16A-7 is a inverted bucket steam trap, and the following use cases show where a unit of this kind is typically applied across oil and gas, utilities, water and manufacturing in Oman and the wider GCC. They are examples based on the described function and not a guarantee of suitability, so the actual operating data should always be checked.

  • Replacing traps on universal connector stations in refineries and chemical plants, where the connector stays in the line and only the trap is swapped.
  • Dirty condensate service in utilities where the bucket design copes with debris.
  • Process steam lines in manufacturing where corrosion resistance is useful.

Selection and compatibility notes

Selecting the IB 16A-7 correctly starts with the process data. Collect the operating pressure, the maximum and minimum temperature, the fluid, the flowrate and the connection standard of the existing pipework, then compare them with the datasheet. The notes below summarise the main decision points for this model.

  • Choose the orifice from the differential pressure of the line.
  • Confirm the connector type, or order with the UC 36 or UCY 36.
  • The ring flange is supplied loose and must be fitted to the connector.

Installation and commissioning of the IB 16A-7

Before installing the IB 16A-7, flush the line to remove weld spatter, scale and construction debris, because even a robust inverted bucket steam trap can be damaged or held open by foreign particles. Check that the flow direction arrow or the marked inlet on the IB 16A-7 matches the piping, and confirm that the nameplate type, size and pressure rating agree with the purchase documents.

Support the pipework so that no piping stress is transferred to the body of the IB 16A-7. Use new gaskets of a type suitable for the fluid and temperature, tighten flange or union bolts evenly and in a cross pattern, and follow the instructions in the manufacturer installation and operating manual for the exact model. If the equipment is used in a potentially explosive area, the plant operator remains responsible for zoning and for preventing static charge, as the datasheet explains for GESTRA equipment.

During commissioning, bring the system up gradually. Open isolation valves slowly, vent trapped air where the design allows, and observe the IB 16A-7 during the first warm-up for leaks at joints and for unusual noise or vibration. Record the first operating pressure and temperature so that later inspections have a reference.

Maintenance and service

Swap-out is quick on a universal connector; the trap is lifted off after loosening the two screws.

Check the bucket and vent hole for blockage.

A short routine inspection plan helps the IB 16A-7 last longer. Note the date of installation, the service conditions and any events such as water hammer or overpressure. At each planned shutdown, inspect the visible joints, check for external corrosion or leakage and compare performance against the commissioning record. Only use spare parts and gaskets that suit the exact type and rating of the IB 16A-7, and isolate and depressurise the line fully before any work is started.

Related products and ordering notes

Orders for the IB 16A-7 should state the type designation, nominal size, pressure rating, end connection standard, material or version and the quantity required. If you are replacing an existing unit, add the nameplate data and a photograph of the nameplate when possible. The manufacturer family also includes other steam, condensate and flow control products, and we can quote related items together with the IB 16A-7 when you send a combined enquiry. Seven Star LLC does not publish prices on this page, so each enquiry is answered with a written quotation.

Frequently asked questions

What is the maximum operating pressure? 28 bar at 425 degrees C, or 400 psig at 800 degrees F.

What connector does it fit? Universal swivel connectors of all types and makes.

Which differential pressures are available? 4.8, 8.6, 17.2 and 27.6 bar, depending on orifice.

What material is the body? 1.4306 / A240-304L stainless steel. Please confirm against the manufacturer datasheet.

Is a flange included? A ring flange is supplied but not fitted.

Documents and quotation

The manufacturer datasheet for the IB 16A-7 is attached to this page as a PDF so you can verify every value above and share it with your engineering team. To receive a quotation, send an RFQ that includes the part number IB 16A-7, the nominal size, the pressure rating and connection type, and the quantity you need. Our team in Muscat will confirm availability and lead time and reply with a written offer for delivery to Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet GESTRA IB 16A-7 Inverted Bucket Steam Trap for Universal Con Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

GESTRA is the German steam and condensate specialist behind the UNA ball float steam traps, the MPA blowdown valves and a long line of boiler level and conductivity controls. It was founded in Bremen in 1902 by Gustav F. Gerdts, and has been part of Spirax Sarco since 2017.

Seven Star LLC is an independent supplier in Muscat. We list GESTRA steam traps, blowdown valves and boiler control equipment, and supply GESTRA parts and spares to boiler houses and process plants in Oman and the GCC.

GESTRA company profile

Established 29 October 1902, Bremen, Germany, by Gustav Friedrich Gerdts; renamed Gustav F. Gerdts KG in 1907
Ownership history Became a stock corporation (GESTRA AG) in 1987, was taken over by Flowserve in 2002, and has been part of the Spirax Sarco group since 2017
Product families Steam traps, non-return and check valves, boiler blowdown valves, control valves, and boiler control electronics for level, conductivity and temperature
Applications Steam boilers, steam distribution and condensate return in process plants, power stations, hospitals, food and textile plants

Milestones

  • 1902: Gustav Friedrich Gerdts founds the company in Bremen on 29 October.
  • 1907: The company is renamed Gustav F. Gerdts KG.
  • 1987: It becomes a stock corporation, GESTRA AG.
  • 2002: Flowserve takes over GESTRA.
  • 2017: GESTRA becomes part of the Spirax Sarco group.

GESTRA products we list

Series Type What it does
UNA 45, UNA 16, UNA 38 Ball float steam traps Continuous condensate discharge from heat exchangers and process equipment; the UNA 38 is the high-pressure version (PN 100)
BK 45 Bimetallic steam trap Robust trap for steam main drainage and tracing, resistant to water hammer
MK 45, TK 23, SMK 22-81 Thermostatic steam traps Air venting and condensate discharge; the SMK 22-81 is the sanitary version for clean steam
MPA 46 Rapid-action blowdown valve Short, intermittent bottom blowdown that removes sludge from the boiler
NRS 1-54, NRR 2-50, NRR 2-60, NRGT 26-2 Boiler level controls Water level limiting, feedwater control and continuous level measurement
LRGT 16-1, LRR 1-50 Conductivity measurement and control Keeps boiler water conductivity in range through continuous blowdown
TRS 5-50 Safety temperature limiter SIL 3 temperature limiting for boilers and hot water systems

The type of steam trap follows the duty. Ball float traps discharge condensate as soon as it forms, which suits heat exchangers with changing loads. Thermostatic and bimetallic traps hold condensate back slightly and suit steam mains, tracing and air venting. On the boiler itself, GESTRA level and conductivity electronics work as a system: electrodes or transmitters in the boiler, controllers in the panel, and the feedwater and blowdown valves they drive.

Where GESTRA products are used

In Oman and the GCC, GESTRA equipment is used in boiler houses of refineries, petrochemical and fertiliser plants, power and desalination stations, food and beverage plants, laundries, hotels and hospitals.

Ordering GESTRA parts: what we need

Send the type designation, pressure rating (PN) and connection size (DN), the end connection (flanged, screwed or socket weld), the operating pressure and condensate load for steam traps, and the supply voltage and bus type (CAN bus, 4-20 mA) for control equipment. For electrodes, add the insertion length.

Facts checked against GESTRA company history and Bremen city records, October 2026.

FAQ

Questions about the GESTRA IB 16A-7 Inverted Bucket Steam Trap for

Answers from our engineering team on installation, compatibility and integration.

01What is the maximum operating pressure?
28 bar at 425 degrees C, or 400 psig at 800 degrees F.
02What connector does it fit?
Universal swivel connectors of all types and makes.
03Which differential pressures are available?
4.8, 8.6, 17.2 and 27.6 bar, depending on orifice.
04What material is the body?
1.4306 / A240-304L stainless steel. Please confirm against the manufacturer datasheet.
05Is a flange included?
A ring flange is supplied but not fitted.